Salvatore Tedesco

Mr. Salvatore Tedesco

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MMMatteo Menolotto
Matteo Menolotto
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
STSalvatore Tedesco
Salvatore Tedesco
BOBrendan O'Flynn
Brendan O'Flynn
MWMichael Walsh
Michael Walsh
The rapid technological advancements of Industry 4.0 have opened up new vectors for novel industrial processes that require advanced sensing solutions for their realization. Motion capture (MoCap) sensors, such as visual cameras and inertial measurement units (IMUs), are frequently adopted in industrial settings to support solutions in robotics, additive manufacturing, teleworking and human safety. This review synthesizes and evaluates studies investigating the use of MoCap technologies in industry-related research. A search was performed in the Embase, Scopus, Web of Science and Google Scholar. Only studies in English, from 2015 onwards, on primary and secondary industrial applications were considered. The quality of the articles was appraised with the AXIS tool. Studies were categorized based on type of used sensors, beneficiary industry sector, and type of application. Study characteristics, key methods and findings were also summarized. In total, 1682 records were identified, and 59 were included in this review. Twenty-one and 38 studies were assessed as being prone to medium and low risks of bias, respectively. Camera-based sensors and IMUs were used in 40% and 70% of the studies, respectively. Construction (30.5%), robotics (15.3%) and automotive (10.2%) were the most researched industry sectors, whilst health and safety (64.4%) and the improvement of industrial processes or products (17%) were the most targeted applications. Inertial sensors were the first choice for industrial MoCap applications. Camera-based MoCap systems performed better in robotic applications, but camera obstructions caused by workers and machinery was the most challenging issue. Advancements in machine learning algorithms have been shown to increase the capabilities of MoCap systems in applications such as activity and fatigue detection as well as tool condition monitoring and object recognition.

3 June 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
KMKevin Moore
Kevin Moore
EOEmma O'Shea
Emma O'Shea
LKLorna Kenny
Lorna Kenny
JBJohn Barton
John Barton
STSalvatore Tedesco
Salvatore Tedesco
STSuzanne Timmons
Suzanne Timmons
Background: Older adults may use wearable devices for various reasons, ranging from monitoring clinically relevant health metrics or detecting falls to monitoring physical activity. Little is known about how this population engages with wearable devices, and no qualitative synthesis exists to describe their shared experiences with long-term use. Objective: This study aims to synthesize qualitative studies of user experience after a multi-day trial with a wearable device to understand user experience and the factors that contribute to the acceptance and use of wearable devices. Methods: We conducted a systematic search in CINAHL, APA PsycINFO, PubMed, and Embase (2015-2020; English) with fixed search terms relating to older adults and wearable devices. A meta-synthesis methodology was used. We extracted themes from primary studies, identified key concepts, and applied reciprocal and refutational translation techniques; findings were synthesized into third-order interpretations, and finally, a “line-of-argument” was developed. Our overall goal was theory development, higher-level abstraction, and generalizability for making this group of qualitative findings more accessible. Results: In total, we reviewed 20 papers; 2 evaluated fall detection devices, 1 tested an ankle-worn step counter, and the remaining 17 tested activity trackers. The duration of wearing ranged from 3 days to 24 months. The views of 349 participants (age: range 51-94 years) were synthesized. Four key concepts were identified and outlined: motivation for device use, user characteristics (openness to engage and functional ability), integration into daily life, and device features. Motivation for device use is intrinsic and extrinsic, encompassing many aspects of the user experience, and appears to be as, if not more, important than the actual device features. To overcome usability barriers, an older adult must be motivated by the useful purpose of the device. A device that serves its intended purpose adds value to the user’s life. The user’s needs and the support structure around the device—aspects that are often overlooked—seem to play a crucial role in long-term adoption. Our “line-of-argument” model describes how motivation, ease of use, and device purpose determine whether a device is perceived to add value to the user’s life, which subsequently predicts whether the device will be integrated into the user’s life. Conclusions: The added value of a wearable device is the resulting balance of motivators (or lack thereof), device features (and their accuracy), ease of use, device purpose, and user experience. The added value contributes to the successful integration of the device into the daily life of the user. Useful device features alone do not lead to continued use. A support structure should be placed around the user to foster motivation, encourage peer engagement, and adapt to the user’s preferences.

5 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea AncillaoAndrea Ancillao
Andrea Ancillao
STSalvatore Tedesco
Salvatore Tedesco
JBJohn Barton
John Barton
BOBrendan O'Flynn
Brendan O'Flynn
In the last few years, estimating ground reaction forces by means of wearable sensors has come to be a challenging research topic paving the way to kinetic analysis and sport performance testing outside of labs. One possible approach involves estimating the ground reaction forces from kinematic data obtained by inertial measurement units (IMUs) worn by the subject. As estimating kinetic quantities from kinematic data is not an easy task, several models and protocols have been developed over the years. Non-wearable sensors, such as optoelectronic systems along with force platforms, remain the most accurate systems to record motion. In this review, we identified, selected and categorized the methodologies for estimating the ground reaction forces from IMUs as proposed across the years. Scopus, Google Scholar, IEEE Xplore, and PubMed databases were interrogated on the topic of Ground Reaction Forces estimation based on kinematic data obtained by IMUs. The identified papers were classified according to the methodology proposed: (i) methods based on direct modelling; (ii) methods based on machine learning. The methods based on direct modelling were further classified according to the task studied (walking, running, jumping, etc.). Finally, we comparatively examined the methods in order to identify the most reliable approaches for the implementation of a ground reaction force estimator based on IMU data.

19 June 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
STSalvatore Tedesco
Salvatore Tedesco
MSMarco Sica
Marco Sica
Andrea AncillaoAndrea Ancillao
Andrea Ancillao
STSuzanne Timmons
Suzanne Timmons
JBJohn Barton
John Barton
BOBrendan O'Flynn
Brendan O'Flynn
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Few studies have investigated the validity of mainstream wrist-based activity trackers in healthy older adults in real-life, as opposed to laboratory settings. Objective: This study explored the performance of two wrist-worn trackers (Fitbit Charge2 and Garmin Vivo Smart HR+) estimating steps, energy expenditure, moderate-to-vigorous physical activity (MVPA) levels, and sleep parameters (TST and WASO) against gold-standard technologies in a cohort of healthy older adults in free-living environment. Methods: Overall, 20 subjects (> 65 years) took part in the study. The devices were worn by the subjects for 24 hours, and the results were compared against validated technology (ActiGraph and New Lifestyles NL-2000i). Mean error, MAPE, ICC and Bland-Altman plots were computed for all the parameters considered. Results: Regarding step-counting, all the trackers are highly correlated with each other (ICCs > 0.89). While Fitbit tends to over-count steps (MPE: 12.36%), Garmin and ActiGraph under-count with a MPE of 9.36% and 11.53%. Garmin had poor ICC values when considering energy expenditure compared against the criterion. Fitbit has moderate-to-good ICCs when compared against the other activity trackers, and showed the best results (MAPE: 12.25%) even if underestimated the amount of calories burnt. For MVPA levels estimation, the wristband trackers were highly correlated (ICC = 0.96), however, were moderately correlated against the criterion and over-estimated the minutes of MVPA activity. When analyzing the sleep parameters, the ICCs were poor for all cases, except when comparing Fitbit with the criterion, which showed a moderate agreement. TST is slightly over-estimated with the Fitbit, although providing good results with an average MAPE equal to 10.13%. On the other hand, WASO estimation was poorer and was over-estimated by Fitbit but under-estimated by Garmin. Again, Fitbit was the most accurate, with an average MAPE of 49.7%. Conclusions: Results suggest that the tested well-known devices could be adopted to estimate steps, energy expenditure, and sleep duration with an acceptable level of accuracy in the population of interest, while clinicians should be cautious in considering other parameters for clinical and research purposes.

3 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
STSalvatore Tedesco
Salvatore Tedesco
JBJohn Barton
John Barton
BOBrendan O'Flynn
Brendan O'Flynn
The objective assessment of physical activity levels through wearable inertial-based motion detectors for the automatic, continuous and long-term monitoring of people in free-living environments is a well-known research area in the literature. However, their application to older adults can present particular constraints. This paper reviews the adoption of wearable devices in senior citizens by describing various researches for monitoring physical activity indicators, such as energy expenditure, posture transitions, activity classification, fall detection and prediction, gait and balance analysis, also by adopting consumer-grade fitness trackers with the associated limitations regarding acceptability. This review also describes and compares existing commercial products encompassing activity trackers tailored for older adults, thus providing a comprehensive outlook of the status of commercially available motion tracking systems. Finally, the impact of wearable devices on life and health insurance companies, with a description of the potential benefits for the industry and the wearables market, was analyzed as an example of the potential emerging market drivers for such technology in the future.

4 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMarco Sica
Marco Sica
STSalvatore Tedesco
Salvatore Tedesco
CCColum Crowe
Colum Crowe
LKLorna Kenny
Lorna Kenny
KMKevin Moore
Kevin Moore
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
Parkinson’s disease (PD) is a progressive neurological disorder of the central nervous system that deteriorates motor functions, while it is also accompanied by a large diversity of non-motor symptoms such as cognitive impairment and mood changes, hallucinations, and sleep disturbance. Parkinsonism is evaluated during clinical examinations and appropriate medical treatments are directed towards alleviating symptoms. Tri-axial accelerometers, gyroscopes, and magnetometers could be adopted to support clinicians in the decision-making process by objectively quantifying the patient’s condition. In this context, at-home data collections aim to capture motor function during daily living and unobstructedly assess the patients’ status and the disease’s symptoms for prolonged time periods. This review aims to collate existing literature on PD monitoring using inertial sensors while it focuses on papers with at least one free-living data capture unsupervised either directly or via videotapes. Twenty-four papers were selected at the end of the process: fourteen investigated gait impairments, eight of which focused on walking, three on turning, two on falls, and one on physical activity; ten articles on the other hand examined symptoms, including bradykinesia, tremor, dyskinesia, and motor state fluctuations in the on/off phenomenon. In summary, inertial sensors are capable of gathering data over a long period of time and have the potential to facilitate the monitoring of people with Parkinson’s, providing relevant information about their motor status. Concerning gait impairments, kinematic parameters (such as duration of gait cycle, step length, and velocity) were typically used to discern PD from healthy subjects, whereas for symptoms’ assessment, researchers were capable of achieving accuracies of over 90% in a free-living environment. Further investigations should be focused on the development of ad-hoc hardware and software capable of providing real-time feedback to clinicians and patients. In addition, features such as the wearability of the system and user comfort, set-up process, and instructions for use, need to be strongly considered in the development of wearable sensors for PD monitoring.