1 September 2018 in Journal of Building Engineering
15 April 2016 in Journal of the Indian Society of Remote Sensing
18 March 2016 in Journal of Earth System Science
1 May 2016 in Journal of the Geological Society of India
The purpose of this study was to identify the groundwater potential zones in Noyyal river basin using GIS and electrical resistivity. River Noyyal was perennial with good flow till early seventies. In recent years, the scene has changed drastically and the river has become practically seasonal and receives copious water during northeast monsoon from September to November. The rest of the years it remains more or less dry. Since the surface water resources in the area are inadequate to meet the local needs it is necessary to explore groundwater resources which has not been done properly. Hence various thematic maps have been used for the preparation of groundwater prospective map by integrating geology, geomorphology, slope, drainage and lineament of the study area. Electrical resistivity survey was conducted at 52 locations by using Schlumberger configuration. From this weathered thickness and depth to basement have been taken and overlaid for identifying groundwater potential sites and finally this result was compared with yield data. The interpretation shows that the entire study area has moderate to good category of groundwater potential.
25 June 2025 in Results in Engineering
ACAjith Arul Daniel Selsam Chandradoss
Ajith Arul Daniel Selsam Chandradoss
30 September 2019 in International Journal of Recent Technology and Engineering (IJRTE)
Reinforced cement concrete is a common material used for building constructions. In this work a trial has been created to utilize steel fibres in RCC members to extend strength and conjointly to extend resistance to impact load. Hooked end steel fibres (HESF) are used here for the preparation of concrete specimens. Concrete grade of M30 is selected and mix design was carried out for target strength of 38.25 N/mm2. Varied volume fractions of HESF such as 0%, 1%, 2%, 3% and 4% were added to concrete. Cube, beam and cylindrical specimens were cast with good compaction and cured fully as per standards. Hardened concrete strength of all the specimens with different quantities of HEFS were tested. Simple drop weight test was conducted on the specimens reinforced with different percentages of steel fibres. The impact load is produced by means of dropping a weight of 5.5 kg from 400 mm height. Impact energy of the specimens is derived from number of blows required to produce initial crack (N1) and number of blows to cause complete failure (N2). Impact energy of the specimens with different quantities of fibres are compared. Results indicated that the concrete specimens with 3% volume fraction of fibre has shown best performance and it is also seen that the increase in volume of fibre beyond 3% has resulted in reduced impact energy.