Reinforced cement concrete is a common material used for building constructions. In this work a trial has been created to utilize steel fibres in RCC members to extend strength and conjointly to extend resistance to impact load. Hooked end steel fibres (HESF) are used here for the preparation of concrete specimens. Concrete grade of M30 is selected and mix design was carried out for target strength of 38.25 N/mm2. Varied volume fractions of HESF such as 0%, 1%, 2%, 3% and 4% were added to concrete. Cube, beam and cylindrical specimens were cast with good compaction and cured fully as per standards. Hardened concrete strength of all the specimens with different quantities of HEFS were tested. Simple drop weight test was conducted on the specimens reinforced with different percentages of steel fibres. The impact load is produced by means of dropping a weight of 5.5 kg from 400 mm height. Impact energy of the specimens is derived from number of blows required to produce initial crack (N1) and number of blows to cause complete failure (N2). Impact energy of the specimens with different quantities of fibres are compared. Results indicated that the concrete specimens with 3% volume fraction of fibre has shown best performance and it is also seen that the increase in volume of fibre beyond 3% has resulted in reduced impact energy.
1 December 2024 in Civil and Environmental Engineering Reports
Humans are consuming vast quantities of plastic across various types, leading to significant challenges in decomposition and the subsequent generation of extensive plastic waste, posing a significant threat to the environment. To address this issue, researchers are actively exploring methods to minimize plastic waste and mitigate its widespread impact by incorporating it into concrete. This not only enhances concrete's durability but also reduces costs. This paper provides an overview of published research on the utilization of waste plastic in concrete. It reviews the efforts of numerous researchers in valorizing plastic waste in concrete, exploring different forms such as partial replacement of fine and coarse aggregate, as well as fibers, and examines their effects on the fresh, mechanical, and durability properties of concrete. The research findings indicate promising possibilities for recycling plastic waste in concrete. However, there is scope to investigate the combined utilization of plastic as both aggregate and fiber in concrete, potentially enabling the recovery of additional quantities of plastic waste. Furthermore, the study emphasizes the importance of employing scanning electron microscopy (SEM) to analyze changes occurring within the concrete.
5 October 2024 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
There is a significant problem in Middle Eastern countries with respect to climate change and rainwater management. This research discusses the influence of water-cement ratio (W/C) and aggregate size on pervious concrete strength and permeability. In this research, the impact of different aggregate sizes with different water-cement ratios are examined in the pervious concrete. The main results are that pervious concrete with a 0.4 water-cement ratio and a coarse aggregate of 10 mm got the highest compressive strength (15.7 MPa at 7 days, 16.83 MPa at 28 days). The results show that the W/C directly influenced compression strength, whereas the coarse aggregate’s size directly affected water content, increasing strength. Pervious concrete made with 10 mm aggregate was found to have better compressive strength, flexural strength, and permeability than 20 mm aggregate. Due to working ability, paste coating, and paste density, it acquires strength with a slightly higher water-cement ratio. With a somewhat higher water-cement ratio, the paste contained fewer open pores, which improved the load transfer and enhanced the compressive strength. The void content in the pervious concrete was considerably higher than that of standard concrete, which influenced the formation and strength of hydration products. These findings are instrumental in tuning the performance of pervious concrete to different conditions, especially when its application needs to be more sustainable.