Astrophysics and cosmology in the coming decades urgently need a large field-of-view (FOV), highly multiplexed spectroscopic survey telescope satisfying challenging image quality and stability requirements. The 6.5 m MUltiplexed Survey Telescope (MUST) proposed by Tsinghua University will be constructed on the Saishiteng Mountain of Northwest China to improve the spectroscopic survey capability of ground-based optical telescopes. In this paper, we demonstrate the conceptual design of the optical system of MUST. MUST will adopt a 6.5 m primary mirror, a 2.45 m secondary mirror, and a multiple-element widefield corrector (WFC) to ensure excellent image quality with an 80% encircled energy size of image spots less than ~ 0.6 arcsec in diameter for the entire 3° FOV and the whole 50° zenith angle range. Thanks to its compact 6.5 m Ritchey-Chretien system and 20,000 optical fibers on its Cassegrain focus, MUST will carry out state-of-the-art wide-field spectroscopic surveys with efficiency ~ 19 times higher than the Dark Energy Spectroscopic Instrument (DESI) using a measure proposed by Ellis et al. Upon completion around 2029, MUST will be one of the world's most advanced wide-field spectroscopic survey telescopes and a new essential reference for the future development of wide-field survey telescopes. It will enable significant advances in many fields in astrophysics and cosmology.
The development of modern large-scale spectroscopic survey telescopes responds to the urgent demand for spectral information in astronomical research. Tsinghua University has previously proposed a 6.5 m MUltiplexed Survey Telescope consisting of a Ritchey-Chretien configuration and a 1.8 m multi-element wide-field corrector, achieving excellent performance and world-leading survey efficiency. However, an optimized 1.65 m multi-element corrector with five lenses is proposed to overcome the constraints on glass uniformity and verification in fabrication of the previous corrector design. It maintains outstanding image quality, with the 80% enclosed energy diameter not more than 0.559 arcsec within 3° FoV over up to a 55° zenith angle. The optimized optical system does not revise the working mode of the ADC or the curvature of the primary mirror while ensuring the reasonability and accuracy of manufacturing of large corrector elements. It provides a more feasible reference optical design for the MUltiplexed Survey Telescope in subsequent iterations and communications with manufacturers.
Conventional phase measuring deflectometry (PMD) takes up a large measurement space and is not suitable for compact online measurement, as the liquid crystal display (LCD) has to be placed in parallel with the mirror under test. In this paper, a compact online phase measuring deflectometry (COPMD) with the LCD screen set perpendicular to the mirror under test is presented for surface shape distortion real-time measurement. The configuration of the COPMD in an enclosed laser cavity is proposed, and the principle of the method is theoretically derived by using the vector-form reflection law. Based on the analysis model, the fringe modulation regulation of the LCD is revealed, and the measurement errors caused by misalignments of the components are illustrated. The validity and flexibility of the COPMD method are verified in the experiment by using a single-actuator deformable mirror as the mirror under test and the PMD method as the comparison. The proposed COPMD method remarkably expands the application range of the conventional PMD method, as it could make efficient use of compact space and is applicable for real-time measurement in enclosed laser facilities and assembled laser systems.
In recent decades, rapid advances in astronomical imaging campaigns have generated an urgent need for detailed spectroscopic surveys with increased speed and efficiency. The 6.5 m MUltiplexed Survey Telescope (MUST) aims to address these current demands. The performance of the multi-object fiber-fed spectrograph (MOFS) plays a critical role for spectroscopic survey telescopes, directly influencing the realization of scientific aims. In this paper, we demonstrate a high-resolution and highly-multiplexed option for MOFS of MUST. The system is believed to be first to apply a 92 mm × 92 mm large-size detector in a Schmidt-like camera and reduces the average central obscuration to 14%. Thanks to the F/1.25 camera design with excellent image quality, the spectrograph achieves up to 800 150µm-large-core optical fibers integration. It can obtain the broadband spectral information (395 nm–435 nm, 520 nm–570 nm, 610 nm–680 nm) of 800 objects with a high resolution of >16,000 within one exposure. The spectrograph theory, design method, and final system scheme of the MOFS can offer good reference and guidance for the spectrograph design in the spectroscopic survey.
The Multiplexed Survey Telescope (MUST) is a 6.5-meter class wide-field survey telescope set to be constructed in Lenghu Town, China. It features a concave hyperbolic primary mirror (M1) and a convex hyperbolic secondary mirror (M2). The M2 system is crucial for achieving the high image quality of MUST over a field of view (FOV) of 2.8° and must maintain precise surface accuracy under varying attitudes and environmental temperatures. To address the challenges associated with measuring and supporting large-aperture convex secondary mirrors, a novel secondary mirror system based on flexible passive support was proposed for MUST. This system enables the sub-aperture stitching measurement of the M2 during manufacturing under different attitudes and ensures stable performance across a wide temperature range of -40°C to +40°C, as well as operating attitudes from 0° to 90°. This paper presents the design, finite element modeling, and simulation results of the M2 system, exploring the effects of gravity, temperature variations, and assembly errors on M2 surface distortion and wavefront aberrations for the MUST telescope.
Shack-Hartmann (SH) wavefront sensing is widely applied to astronomical observations with its fast and accurate measurement. However, due to the computational nature of SH that the input beam is segmented to provide local wavefront slopes, the sampling density of the sub-apertures and the calculation accuracy of each sub-focal spot’s centroid have great influence on the wavefront reconstruction accuracy. Therefore, it is usually difficult to achieve high resolution wavefront reconstruction for dark stars in the astronomical observations with insufficient light intensity. We present a neural-network assisted high resolution SH wavefront sensing method to overcome the shortages and obtain results with enhanced resolution from the separated information inside each sub-aperture. With this method, high resolution wavefront sensing in darker sky area could be realized.