18 November 2021 in Journal of Thermal Engineering
The paper investigates the heat transfer characteristics of the heat exchanger under two different configurations namely taper helical tube and spiral tube type heat exchanger. The working fluid is water which flows in tubes kept horizontally and the mass flow rate ranges from 0.04 kg/s to 0.16 kg/s. The effect of tube configuration parameters and Reynolds number on heat transfer coefficient and Nusselt number were studied. Regression equations have been developed for both the configurations under horizontal orientation using various process parameters and regression tools available in Minitab Software. A comparison has been made between the theoretical results and the results obtained from simulation gives an error of 15% which is well within the permissible limit. The result indicates that the highest value of Nusselt number is greater by 21% than taper helical tube heat exchanger which is attributed to better heat transfer characteristics of spiral tube heat exchanger and hence the former is thermally superior over the latter. In this study, temperature and velocity contour have been developed for both the configurations which clearly indicates that, when heat transfer is considered, spiral configuration should be preferred over taper helical configuration.
1 March 2018 in IOP Conference Series: Materials Science and Engineering
The solar photovoltaic (PV) panel driven refrigeration system employs solar PV panel and play a vital role when combined with storage batteries. The variation in performance of solar PV panel driven refrigeration system has been experimentally investigated in this paper. The change in battery voltage is analyzed with respect to panel size. Different series and parallel combinations have been applied on four solar PV panels of 35W each to get 24V. With the above combination a current in the range of 3-5 ampere has been obtained depending upon the solar intensity. A refrigerator of 110 W and 50 liters is used in the present investigation which requires 0.80 ampere AC at 230 V. The required current and voltage has been obtained from an inverter which draws about 7 ampere DC from the battery bank at 24V. The compressor of the refrigerator consumed 110W which required a PV panel size of 176 W approximately. It is important to note that the compressor consumed about 300W for first 50 milliseconds, 130 W for next five seconds and gradually comes to 110 W in 65 seconds. Thus panel size should be such that it may compensate for the initial load requirement.
1 January 2024 in International Journal of Energy Research
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
16 June 2026 in The TQM Journal
Purpose: In today's competitive world, there is a need to adopt the ever-growing technologies for improving the productivity of organizations by implementing the synergy of safety and modern digital technologies of Industry 4.0. This study examines the results of applying safety and regulatory tools across various processes in line with the principles of Industry 4.0. Design/methodology/approach: Data were analyzed using expert's opinion through Real-Time Delphi method, and the best flute instrument was found through data analysis. Research emphasized Industry 4.0 and ability of advanced technology to influence safety and sustainability practices in risk-specific environments, which includes IoT, AI, advanced analytics, and CREA, etc. Findings: It has increased the possibilities for real-time threat detection and streamlined every process. However, managing and interpreting the data generated by these automation processes requires skilled personnel and other resources, while data security and management have the potential to reduce the chances of breaches. Practical implications: This digital transformation helps in improving the productivity and safety of the organizations along with the positive impacts on employees' behavior, change acceptance, and work complexity. Originality/value: The study provides a roadmap for Industry 4.0 implementation in the process industries, focusing on employee development, incremental acquisition and implementation of technology and collaboration among stakeholders.