Mahendra Bhadu

Mahendra Bhadu

Auto-generated profile, based on publicly available information

Mahendra Bhadu

Electrical Engineering Department, Engineering College Bikaner, Rajasthan, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in IETE Journal of Research
Verified
Journal Article
Closed access
AKArvind Kumar
Arvind Kumar
MBMahendra Bhadu
Mahendra Bhadu
AAAmit Arora
Amit Arora
This paper presents a coordinated wide-area damping control of power system stabilizers (PSSs), static synchronous compensator (STATCOM), and static synchronous series compensator (SSSC) for grid-forming based wind and solar PV generation resources. The main objective of this work is to enhance the damping for inter-area oscillations while maintaining the voltage and frequency in the prescribed range, taking into consideration the operational uncertainties. Better voltage and reactive power support are provided by the use of STATCOM and for additional damping, an SSSC is employed with the coordinated wide-area damping controller (CWADC). Variable-speed wind turbine control methodology strategically combined with inertia control, de-loading control, pitch angle control, and electronic rotor speed control is employed to obtain an optimum response for discontinuous generation mixes and variable wind speed. The geometric measures of controllability/observability and residues method have been utilized to choose the appropriate input control signals and optimal location of CWADC. A multi-objective salp swarm algorithm has been used to optimize the parameters of the proposed CWADC. To demonstrate the efficacy of the proposed CWADC, nonlinear time-domain simulations are performed on a modified IEEE 68-bus test system embedded with hybrid wind-solar power plants considered multiple time delays.

16 December 2023 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
HKHarish Kumar Khyani
Harish Kumar Khyani
JVJayashri Vajpai
Jayashri Vajpai
RKRajendra Karwa
Rajendra Karwa
MBMahendra Bhadu
Mahendra Bhadu
The rise in the temperature severely affects photovoltaic cell efficiency and hence its power output. Moreover, it also causes the development of thermal stresses that may reduce their life span. Thus, there is a need for an accurate estimation of the cell’s working temperature. In this paper, a detailed thermal model based on various heat transfer modes involved and their governing equations has been presented to estimate the cell temperature of a PV module using MATLAB software under different climatic and solar insolation conditions. In order to validate the presented model, an experimental setup has been built and operated under actual outdoor conditions of Jodhpur, a city in the Thar Desert of Rajasthan. For the peak summer month of June, the predicted glass cover outer surface temperature has been found to be within 0.2–4.5°C of experimentally measured values and the back sheet temperature is found to be within 0.5–5.5°C. The predicted and measured power outputs have been found to be within 0.85–1.2 W while the efficiency values are within 0.17–0.38%. For the early summer month of April, the variations are 0.13–4.1°C, 0.2–4.1°C, 0.44–1.65 W, and 0.1–0.5% for glass cover temperature, back sheet temperature, power output, and efficiency, respectively. Thus, the predictions of the developed thermal model have exhibited a good agreement with the experimental results. The maximum glass cover temperatures recorded were 60°C and 65.5°C when the ambient temperatures were 35°C and 42°C near the noon for the early summer and peak summer day experiments, respectively. The presented model can be used to generate a year-round cell temperature data for the known environmental data of a location, which can help in the selection or development of appropriate cooling technology at the planning stage of the installation of a solar PV plant.

29 January 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
PMPrahlad Mundotiya
Prahlad Mundotiya
MBMahendra Bhadu
Mahendra Bhadu
HTH. P. Tiwari
H. P. Tiwari

1 February 2024 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
TJTanmay Jain
Tanmay Jain
KVKusum Verma
Kusum Verma
MBMahendra Bhadu
Mahendra Bhadu
Unpredictable variations in load demand and unanticipated component failures are progressively impacting the operation of modern power systems, making system evaluation more stochastic in nature. Although deterministic approaches were formerly the norm for determining system status, probabilistic approaches have greatly improved the capacity to capture the stochastic behavior characteristic of power system operations. The presented work in the paper recommends the use of probabilistic modelling approaches with deterministic approaches, highlighting their crucial function in augmenting the reliability and security of contemporary power systems to unanticipated failures. In this paper, N1 security criteria based reliability of the composite power system (CPS) is proposed using an integrated deterministic and probabilistic framework (D-P) considering outage of the transmission line. For the deterministic approach (DA), line overloading on available lines is determined using the static security index (SSI). For the probabilistic approach (PA), reliability indices such as expected loss of power (ELOP), expected frequency of contingency (EFOC), expected loss of load (ELOL), probability of load curtailment (PLC), and expected duration of load curtailments (EDLC) are calculated. Further, for each contingency, a performance index is determined using both approaches to assess the severity of the contingency that occurred on the power system. Based on the N1 security criteria based reliability analysis using an integrated D-P framework, a credible critical set of transmission lines is obtained, which can serve as important information to system operators. The proposed techniques have been tested on IEEE 24 bus reliability test system (RTS).

1 January 2024 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
MKMukesh Kumar
Mukesh Kumar
ASAjay Sharma
Ajay Sharma
NSNirmala Sharma
Nirmala Sharma
FSFani Bhushan Sharma
Fani Bhushan Sharma
MBMahendra Bhadu
Mahendra Bhadu
The wind farm layout optimization problem (WFLOP) is a significant problem in the field of renewable energy. In this development of wind farm, solving the WFLOP is a crucial task, which entails placing the turbines in the wind farm in the best locations to reduce wake effects and enhance predicted power generation. In recent decades, the WFLOP problem has been solved mathematically. Meanwhile, the growing load demand led to an increase in the complexity of WFLOP. The results obtained by mathematical methods were not accurate enough to suit complexity of WFLOP. Nowadays, researchers from a variety of fields are developing nature‐inspired algorithms (NIAs) to solve difficult real‐world problems. This study is an attempt to review the most important innovations in the field of NIAs to solve the WFLOP problem. The classification of the reviewed literature is based on different applied approaches and models. In addition to specific proposals, the advantages and disadvantages of certain domains are also discussed. This study provides a future direction to the fellow researchers who are working in the field of WFLOP.

1 January 2024 in International Journal of Energy Research
Verified
Journal Article
Open access
ASAmit Sharma
Amit Sharma
CRC. S. Rajoria
C. S. Rajoria
MBMahendra Bhadu
Mahendra Bhadu
DSDharmendra Singh
Dharmendra Singh
RKRavi Kumar
Ravi Kumar
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.