1 November 2018 in Polymer Degradation and Stability
23 March 2023 in Polymer Degradation and Stability
1 June 2023 in Polymer Testing
15 May 2024 in Journal of Applied Polymer Science
Polypropylene (PP) recyclates face limitations in their use due to lower qualities compared with virgin PP, resulting from contaminations and the mixing of different PP grades. In particular, their high melt flow rate (MFR) hinders their suitability for applications requiring low MFR, such as pipes. This study investigates the feasibility of producing low MFR PP recyclates from packaging waste. For this purpose, recyclates were produced exclusively from manually sorted extrusion blow molding grades and compared with a recyclate derived from a conventional PP waste stream. Different washing temperatures and recyclate production processes were used to study their effects on the properties of the recyclates. The main objective was to determine the lowest achievable MFR and the rheological, mechanical, and thermal properties of the recyclates from improved sorting. The results are intended to serve as reference points for the evaluation of future automatic sorting trials. The enhanced sorting resulted in an 80% reduction in the MFR and improved ductility, thereby extending the potential applications of the recyclate. The different washing and production processes did not have a significant effect on the investigated properties, except for a slight decrease in the MFR with hot washing and the omission of the pelletizing step.
18 June 2025 in Waste Management
The quality of recycled plastics is crucial to make them competitive in more demanding applications and to extend their range of applications. However, there are many influencing factors that can reduce the quality and limit the use of recyclates. One of these factors is degradation, which can occur at different stages of a plastic's life cycle. Degraded material can affect the quality of recyclates. Therefore, it would be beneficial to sort out heavily aged plastics from the recycling stream before further processing. This work investigates the possibility of separating severely degraded polyethylene (PE) from unaged or less degraded PE using near-infrared (NIR) hyperspectral imaging. For this purpose, PE samples were artificially aged using two methods: (i) exposure to UV light, (ii) exposure to aqueous chlorine dioxide solution. The ageing state of the samples was assessed by means of Fourier Transform Infrared (FTIR) spectroscopy and tensile tests and their NIR spectra were recorded on a laboratory NIR sorter. The ability to separate highly degraded from non-/less-degraded samples, which was defined by their mechanical performance, was then analysed using multivariate data analysis and machine learning algorithms applied to the NIR data. These analyses showed promising results for separating highly degraded PE samples, with the classification between degraded and less degraded PE achieving accuracy and F1 scores exceeding 90%.
1 January 2016 in AIP Conference Proceedings
In potable water distribution systems polyethylene (PE) pipes have been successfully used for several decades. In many applications chlorine disinfectants are frequently used to avoid harmful changes in the quality of water. Considering the intense oxidative ability of these substances, it is crucial to determine their influence on the degradation of pipe materials in long-term applications. At Polymer Competence Center Leoben GmbH (PCCL), a new device for material exposure under specific chlorine dioxide (ClO2) conditions was developed which allows significantly accelerated exposure of PE pipe materials. Preliminary tests were conducted in order to ensure stable exposure conditions during several weeks regarding temperature, pH value, ClO2 concentration and oxidative reduction potential (ORP) within a specified accuracy. Two PE grades for pipe applications were selected for conditioning and material testing. Dumbbell specimens of 1 mm thickness were punched out of compression molded sheets and fixed in an especially developed specimen holder made of chlorine resistant polytetrafluoroethylene (PTFE). The samples were exposed at 60 °C, 1 ppm of ClO2, pH of 6.8 resulting in an ORP of 550 mV and removed after 1, 2 and 3 weeks. Based on subsequent tensile tests, thermal analysis (DSC) and IR-spectroscopy (FTIR) a significant change in the mechanical properties as well as a thermo-oxidation was detected, emphasizing the effect of ClO2 on the physical and chemical aging of the materials even after one week of exposure. Optical surface investigation with scanning electron microscopy (SEM) confirmed the significant degradation of the materials revealing several micro cracks all over the specimen surfaces. The first results determined with the new exposure device show the potential of this technique for a tremendous reduction of testing time in order to study the degradation characteristics of polymeric materials under ClO2 exposure. Such information is of high importance to optimize the stabilization of polymers or to develop new stabilizers with improved effectivity.