Jakob Soltau

Jakob Soltau

Auto-generated profile, based on publicly available information

Jakob Soltau

University of Göttingen

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2023 in Optica
Verified
Journal Article
Closed access
JSJakob Soltau
Jakob Soltau
PMPaul Meyer
Paul Meyer
RHRobert Hartmann
Robert Hartmann
LSLothar Strueder
Lothar Strueder
HSHeike Soltau
Heike Soltau
TSTim Salditt
Tim Salditt
We present an approach to full-field x-ray fluorescence imaging that uses a Fresnel zone plate as a coded aperture positioned between the object and detector. For this particular coded aperture, the incoherent image formation is identical to the coherent propagation image (inline hologram) of an equivalent absorption object. In the first experiment, we show that prior knowledge of the coded aperture structure and position is no longer required. Fast and robust reconstruction algorithms well known from coherent imaging can be applied. We demonstrate the approach using x-ray fluorescence excited by a collimated Cu- K α beam at an ordinary laboratory x-ray source. Images are recorded with a field of view of 1 m m 2 and resolution of 35 µm. The simple and efficient imaging scheme is well suited for further dissemination of x-ray fluorescence imaging and translation to a broader user community, which could take advantage of full-field imaging with chemical contrast. More generally, the scheme also enables full-field imaging of other incoherent radiation processes for which lenses are either not available at all or not with sufficient numerical apertures. Examples include Compton imaging, imaging of inelastic neutron scattering, or γ -ray imaging in nuclear medicine.

26 May 2021 in Optica
Verified
Journal Article
Closed access
JSJakob Soltau
Jakob Soltau
MVMalte Vassholz
Malte Vassholz
MOMarkus Osterhoff
Markus Osterhoff
TSTim Salditt
Tim Salditt
X-ray in-line holography is well suited for three-dimensional imaging, since it covers a large field of view without the necessity of scanning. However, its resolution does not extend to the range covered by coherent diffractive imaging or ptychography. In this work, we show full-field holographic x-ray imaging based on cone-beam illumination, beyond the resolution limit given by the cone-beam numerical aperture. Image information encoded in far-field diffraction and in holographic self-interference is treated in a common reconstruction scheme, without the usual empty beam correction step of in-line holography. An illumination profile tailored by waveguide optics and exactly known by prior probe retrieval is shown to be sufficient for solving the phase problem. The approach paves the way toward high-resolution and dose-efficient x-ray tomography, well suited for the current upgrades of synchrotron radiation sources to diffraction-limited storage rings.

31 May 2022 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JSJakob Soltau
Jakob Soltau
MOMarkus Osterhoff
Markus Osterhoff
TSTim Salditt
Tim Salditt
We present a novel approach to x-ray microscopy based on a multilayer zone plate which is positioned behind a sample similar to an objective lens. However, unlike transmission x-ray microscopy, we do not content ourselves with a sharp intensity image; instead, we incorporate the multilayer zone plate transfer function directly in an iterative phase retrieval scheme to exploit the large diffraction angles of the small layers. The presence of multiple diffraction orders, which is conventionally a nuisance, now comes as an advantage for the reconstruction and photon efficiency. In a first experiment, we achieve sub-10-nm resolution and a quantitative phase contrast.

1 December 2021 in Optics Express
Verified
Journal Article
Closed access
JSJakob Soltau
Jakob Soltau
LLLeon Merten Lohse
Leon Merten Lohse
MOMarkus Osterhoff
Markus Osterhoff
TSTim Salditt
Tim Salditt
Recent progress in nanofabrication, namely of multilayer optics, and the construction of coherent hard x-ray sources has enabled high resolution x-ray microscopy with large numerical aperture optics for small focal spot sizes. Sub-10 nm and even sub-5 nm focal spot sizes have already been achieved using multilayer optics such as multilayer Laue lenses and multilayer zone plates. However these optics can not be described by the kinematic theory given their extreme aspect-ratio between the depth (thickness) and the layer width. Moreover, the numerical simulation of these optics is challenging, and the absence of an accessible numerical framework inhibits further progress in their design and utilization. Here, we simulate the propagation of x-ray wavefields within and behind optical multilayer elements using a finite-difference propagation method. We show that the method offers high accuracy at reasonable computational cost. We investigate how small focal spot sizes and highest diffraction efficiency of multilayer optics can be achieved, considering volume diffraction effects such as waveguiding and Pendellösung. Finally, we show the simulation of a novel imaging scheme, allowing for a detailed study of image formation and the development of customized phase retrieval schemes.

22 July 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
JSJakob Soltau
Jakob Soltau
LCLert Chayanun
Lert Chayanun
MLMikhail Lyubomirskiy
Mikhail Lyubomirskiy
JWJesper Wallentin
Jesper Wallentin
MOMarkus Osterhoff
Markus Osterhoff
Using multilayer zone plates (MZPs) as two-dimensional optics, focal spot sizes of less than 10 nm can be achieved, as we show here with a focus of 8.4 nm × 9.6 nm, but the need for order-sorting apertures prohibits practical working distances. To overcome this issue, here an off-axis illumination of a circular MZP is introduced to trade off between working distance and focal spot size. By this, the working distance between order-sorting aperture and sample can be more than doubled. Exploiting a 2D focus of 16 nm × 28 nm, real-space 2D mapping of local electric fields and charge carrier recombination using X-ray beam induced current in a single InP nanowire is demonstrated. Simulations show that a dedicated off-axis MZP can reach sub-10 nm focusing combined with reasonable working distances and low background, which could be used for in operando imaging of composition, carrier collection and strain in nanostructured devices.

24 May 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
FDFlorian Döring
Florian Döring
Marcel RischMarcel Risch
Marcel Risch
BRBenedikt Rösner
Benedikt Rösner
MBMartin Beye
Martin Beye
PBPhilipp Busse
Philipp Busse
CDChristian David
Christian David
X-ray absorption spectroscopy (XAS) is a powerful element-specific technique that allows the study of structural and chemical properties of matter. Often an indirect method is used to access the X-ray absorption (XA). This work demonstrates a new XAS implementation that is based on off-axis transmission Fresnel zone plates to obtain the XA spectrum of La0.6Sr0.4MnO3 by analysis of three emission lines simultaneously at the detector, namely the O 2p–1s, Mn 3s–2p and Mn 3d–2p transitions. This scheme allows the simultaneous measurement of an integrated total fluorescence yield and the partial fluorescence yields (PFY) of the Mn 3s–2p and Mn 3d–2p transitions when scanning the Mn L-edge. In addition to this, the reduction in O fluorescence provides another measure for absorption often referred to as the inverse partial fluorescence yield (IPFY). Among these different methods to measure XA, the Mn 3s PFY and IPFY deviate the least from the true XA spectra due to the negligible influence of selection rules on the decay channel. Other advantages of this new scheme are the potential to strongly increase the efficiency and throughput compared with similar measurements using conventional gratings and to increase the signal-to-noise of the XA spectra as compared with a photodiode. The ability to record undistorted bulk XA spectra at high flux is crucial for future in situ spectroscopy experiments on complex materials.