We systematically investigate the influence of the fabrication process on dielectric loss in aluminum-on-silicon superconducting coplanar waveguide resonators with internal quality factors (Qi) of about one million at the single-photon level. These devices are essential components in superconducting quantum processors; they also serve as proxies for understanding the energy loss of superconducting qubits. By systematically varying several fabrication steps, we identify the relative importance of reducing loss at the substrate–metal and substrate–air interfaces. We find that it is essential to clean the silicon substrate in hydrogen fluoride (HF) prior to aluminum deposition. A post-fabrication removal of the oxides on the surface of the silicon substrate and the aluminum film by immersion in HF further improves the Qi. We observe a small, but noticeable, adverse effect on the loss by omitting either standard cleaning (SC1), pre-deposition heating of the substrate to 300 °C, or in situ post-deposition oxidation of the film’s top surface. We find no improvement due to excessive pumping meant to reach a background pressure below 6 × 10−8 mbar. We correlate the measured loss with microscopic properties of the substrate–metal interface through characterization with x-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry, transmission electron microscopy, energy-dispersive x-ray spectroscopy, and atomic force microscopy.
The advent of nanofocused X-ray beams has allowed the study of single nanocrystals and complete nanoscale devices in a nondestructive manner, using techniques such as scanning transmission X-ray microscopy (STXM), X-ray fluorescence (XRF) and X-ray diffraction (XRD). Further insight into semiconductor devices can be achieved by combining these techniques with simultaneous electrical measurements. Here, we present a system for electrical biasing and current measurement of single nanostructure devices, which has been developed for the NanoMAX beamline at the fourth-generation synchrotron, MAX IV, Sweden. The system was tested on single InP nanowire devices. The mechanical stability was sufficient to collect scanning XRD and XRF maps with a 50 nm diameter focus. The dark noise of the current measurement system was about 3 fA, which allowed fly scan measurements of X-ray beam induced current (XBIC) in single nanowire devices.
1 January 2022 in Journal of Synchrotron Radiation
Coherent X-ray imaging techniques, such as in-line holography, exploit the high brilliance provided by diffraction-limited storage rings to perform imaging sensitive to the electron density through contrast due to the phase shift, rather than conventional attenuation contrast. Thus, coherent X-ray imaging techniques enable high-sensitivity and low-dose imaging, especially for low-atomic-number (Z) chemical elements and materials with similar attenuation contrast. Here, the first implementation of in-line holography at the NanoMAX beamline is presented, which benefits from the exceptional focusing capabilities and the high brilliance provided by MAX IV, the first operational diffraction-limited storage ring up to approximately 300 eV. It is demonstrated that in-line holography at NanoMAX can provide 2D diffraction-limited images, where the achievable resolution is only limited by the 70 nm focal spot at 13 keV X-ray energy. Also, the 3D capabilities of this instrument are demonstrated by performing holotomography on a chalk sample at a mesoscale resolution of around 155 nm. It is foreseen that in-line holography will broaden the spectra of capabilities of MAX IV by providing fast 2D and 3D electron density images from mesoscale down to nanoscale resolution.
1 January 2019 in Journal of Synchrotron Radiation
Here it is demonstrated how nanofocused X-ray beam induced current (XBIC) can be used to quantitatively map the spatially dependent carrier collection probability within nanostructured solar cells. The photocurrent generated by a 50 nm-diameter X-ray beam was measured as a function of position, bias and flux in single p–i–n doped solar-cell nanowires. The signal gathered mostly from the middle segment decays exponentially toward the p- and n-segments, with a characteristic decay length that varies between 50 nm and 750 nm depending on the flux and the applied bias. The amplitude of the XBIC shows saturation at reverse bias, which indicates that most carriers are collected. At forward bias, the relevant condition for solar cells, the carrier collection is only efficient in a small region. Comparison with finite element modeling suggests that this is due to unintentional p-doping in the middle segment. It is expected that nanofocused XBIC could be used to investigate carrier collection in a wide range of nanostructured solar cells.
We demonstrate x-ray absorption fine structure spectroscopy (XAFS) detected by x-ray beam induced current (XBIC) in single n+-i-n+ doped nanowire devices. Spatial scans with the 65 nm diameter beam show a peak of the XBIC signal in the middle segment of the nanowire. The XBIC and the x-ray fluorescence signals were detected simultaneously as a function of the excitation energy near the Ga K absorption edge at 10.37 keV. The spectra show similar oscillations around the edge, which shows that the XBIC is limited by the primary absorption. Our results reveal the feasibility of the XBIC detection mode for the XAFS investigation in nanostructured devices.
Using multilayer zone plates (MZPs) as two-dimensional optics, focal spot sizes of less than 10 nm can be achieved, as we show here with a focus of 8.4 nm × 9.6 nm, but the need for order-sorting apertures prohibits practical working distances. To overcome this issue, here an off-axis illumination of a circular MZP is introduced to trade off between working distance and focal spot size. By this, the working distance between order-sorting aperture and sample can be more than doubled. Exploiting a 2D focus of 16 nm × 28 nm, real-space 2D mapping of local electric fields and charge carrier recombination using X-ray beam induced current in a single InP nanowire is demonstrated. Simulations show that a dedicated off-axis MZP can reach sub-10 nm focusing combined with reasonable working distances and low background, which could be used for in operando imaging of composition, carrier collection and strain in nanostructured devices.