Shijun Qin

Shijun Qin

Auto-generated profile, based on publicly available information

Shijun Qin

Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Fusion Engineering and Design
Verified
Journal Article
Closed access
SQShijun Qin
Shijun Qin
QWQingfeng Wang
Qingfeng Wang
XCXianfeng Chen
Xianfeng Chen

22 April 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
SQShijun Qin
Shijun Qin
DYDamao Yao
Damao Yao
QWQingfeng Wang
Qingfeng Wang
XMXin Mao
Xin Mao
PLPeng Liu
Peng Liu
YSYuntao Song
Yuntao Song
The Chinese Fusion Engineering and Testing Reactor (CFETR) has been performed and is in its engineering design stage. Presently, there are two options allowed for the divertors; the helium-cooled stage and water-cooled stage. The water-cooled one has been focused in this article. The configuration of CFETR divertor module was designed. The cassette design scheme and cassette box inner and outer locking systems were introduced, and the locking system was designed to compliant with the remote-handling (RH) requirements. Two divertor RH design options were provided: one is removed through lower port; the other is targets and baffles removed through upper port; supports and cassette were not removed. The other major research was the water cooling channels' design and its pressure drop calculation. In addition, the fluid, thermal, and mechanical analyses on the outer target were done. Within 10-MW/m2 heat flux, outer target design can ensure that the temperature for all the components works within their temperature limit, and all the components meet the stress design criteria except the copper alloy pipe. The maximum primary stress induced by pressure on the copper alloy pipe appears in the local position between the two monoblocks, which exceeds the design limit. Protection components are need to be added at the gap of the future design optimization to reduce the local stress. After the thermal-hydraulic analysis on water-cooled divertor cassette, the maximum temperature and the maximum stress of cassette meet the requirements. The results of electromagnetic force analysis shows that the deformation on first wall and transition support is less than 0.5 mm, and the maximum stress is also below its tensile strength values. This article summarized the latest achievements in the design and research of CFETR water-cooled diverter in China. All the results will be of great reference for the CFETR divertor optimal design.

1 January 2022 in Fusion Engineering and Design
Verified
Journal Article
Closed access
XCXianfeng Chen
Xianfeng Chen
SQShijun Qin
Shijun Qin
QWQingfeng Wang
Qingfeng Wang
JCJin Cao
Jin Cao

21 June 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
LHL. Hu
L. Hu
HCH. Cao
H. Cao
JZJ. Zhao
J. Zhao
LNL. Niu
L. Niu
YCY. Chen
Y. Chen
SZS. Zhang
S. Zhang
International Thermonuclear Experimental Reactor radial X-ray camera is designed to measure the poloidal profile of the plasma X-ray emission with high spatial and temporal resolutions and will be installed inside equatorial port 12. Due to the harsh environment of neutron and gamma radiations, nuclear radiation hardness of many components has to be considered in design and test, including silicon detector array, electronics, and cabling. As for electronics put in a port cell, a preliminary design of highly integrated preamplifier and program controllable midamplifier has been completed, and many tests have been done to investigate the radiation hardness performance of the amplifiers together with detectors. In the Cf-252 neutron test with flux of ~2.23 × 10 3 n · cm -2 · s -1 and fluence greater than 1.0 × 10 10 n · cm -2 , there was no performance degradation in detector and preamplifier. In the Co-60 gamma test with a dose rate of 0.5 Gy · min -1 and an accumulated dose of 200 Gy, the performance change was not found in preamplifier and midamplifier except for some radiation damage to the power module in the board of preamplifier. In the following accelerator neutron test where the neutron flux is ~5 × 10 7 n·cm -2 ·s -1 and neutron fluence is 2 × 1012 n · cm -2 , the functional problem was not found in preamplifier and cable, while there were occurrences of single-event effect in mid-amplifier. The detector underwent 10% decrease of sensitivity to visible light. In addition, shielding cabinet was designed to provide good protection for electronics inside.

26 April 2014 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
SQShijun Qin
Shijun Qin
YSYuntao Song
Yuntao Song
DYDamao Yao
Damao Yao
YWYuanxi Wan
Yuanxi Wan
SWSongtao Wu
Songtao Wu
YCYong Cheng
Yong Cheng

13 February 2019 in Fusion Science and Technology
Verified
Journal Article
Closed access
KLKun Lu
Kun Lu
SQShijun Qin
Shijun Qin
ZXZhuang Xu
Zhuang Xu
YZYang Zhang
Yang Zhang
GSGuang Shen
Guang Shen
JWJiefeng Wu
Jiefeng Wu
The vacuum vessel (VV), one of the important components for the Chinese Fusion Engineering Test Reactor (CFETR) superconducting magnet tokamak, can provide an ultrahigh vacuum and clean environment for plasma operation. The CFETR VV was preliminarily designed to be a torus with a D-shaped cross section, eight upper vertical ports, eight equatorial ports, and eight lower ports. In order to verify the design and key technologies to be used in the future, a 1/8 VV sector mock-up has been designed and fabricated at the Institute of Plasma Physics, Chinese Academy of Sciences (abbreviated ASIPP). In this paper, the mock-up is used to demonstrate thick austenitic stainless steel plate hot forming, welding, cutting, part segment assembly, and other technologies and developments. The design considerations and criteria of the 1/8 sector mock-up are discussed in detail. Based on these considerations, the main design parameters and characteristics of the 1/8 VV sector mock-up are described, including the inner shells, outer shells, and stiffening ribs between them and the straight line, arcs, and the tangential joint between them. Finally, the research and development of technologies for the mock-up manufacture that has been carried out at ASIPP is discussed.