Madhukar Rao Airineni

Madhukar Rao Airineni

Auto-generated profile, based on publicly available information

Madhukar Rao Airineni

Department of Electrical Engineering, Indian Institute of Technology Hyderabad, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MAMadhukar Rao. A
Madhukar Rao. A
KSK. Sivakumar
K. Sivakumar
In this paper, a fault-tolerant single-phase five-level inverter configuration is proposed for photovoltaic (PV) generation systems. Conventional two-level inverters are popularly used in PV applications, but these inverters provide the output voltage with considerable harmonic content. One of the efficient ways to improve the power quality of PV generation systems is to replace a two-level inverter with a multilevel inverter. Conventional multilevel inverters reduce total harmonic distortion and filter requirements effectively, but it has limitations in terms of reliability due to increased device count and capacitor voltage balancing issues. Therefore, a fault-tolerant single-phase five-level inverter is presented, which is constructed by using a half-bridge two-level inverter, a three-level diode clamp inverter, and a bidirectional switch. The proposed inverter topology can tolerate the system faults due to failure of the source and/or switching devices with least modification in the switching combinations. It has less number of switching devices compared to conventional five-level inverters. The topology also has the energy-balancing capability between sources which helps in reducing uneven charge of batteries in case of partial shading or hotspots on one side of the PV panels. The proposed system under normal and faulty condition is simulated in MATLAB/Simulink environment, and results are verified with a laboratory prototype.

31 July 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BRB. Prathap Reddy
B. Prathap Reddy
MAMadhukar Rao A
Madhukar Rao A
MSManoranjan Sahoo
Manoranjan Sahoo
SKSivakumar Keerthipati
Sivakumar Keerthipati
In this paper, a fault-tolerant multiphase multilevel inverter (MPMLI) configuration is proposed based on the dual inverter concept. This configuration helps to improve the performance of pole-phase modulated multiphase induction motor (PPMMIM) drive in both normal and switch failure conditions. Comparing to the existing multilevel inverter topologies for multiphase induction motor (MIM) drives, the proposed MPMLI configuration requires less number of dc sources and power electronic devices. The proposed MPMLI configuration is able to sustain under various faulty conditions, which can improve the reliability of the system. In addition, dc-link utilization (DLU) in low-pole mode is improved by using space vector pulsewidth modulation (SVPWM). In high-pole mode, carrier-phase-shifted 3-Φ SVPWM is used for reducing the torque ripple. This MPMLI configuration produces a multilevel voltage profile across the effective phase in 3-phase 12-pole mode. By maintaining the V/f ratio constant, the proposed MPMLI-fed MIM drive facilitates a wide range of load torque with half of the rated speed in faulty condition. This advantage makes it suitable for traction and electric vehicle applications where reliability and wide range of torque-speed are the major concerns. The performance of proposed MPMLI-fed 5 hp, 9-φ PPMMIM drive is simulated by finite-element method (FEM) in ANSYS Maxwell 2-D and experimentally verified by laboratory prototype under normal and faulty conditions.

1 March 2017
Verified
Conference Paper
Closed access
BRB. Prathap Reddy
B. Prathap Reddy
BUB. S. Umesh
B. S. Umesh
ARA Madhukar Rao
A Madhukar Rao
BKB.V. Ravi Kumar
B.V. Ravi Kumar
KKK. Siva Kumar
K. Siva Kumar
Multi-phase induction motor (MIM) drives with polephase modulation (PPM) is suitable for the Electric vehicle(EV) applications because of the reasons, like constant power operation with high efficiency over an extended speed-torque range and high reliability. By using Pole-Phase modulation, in this paper a 45-phase squirrel-cage induction motor (IM) drive is proposed with 1:3:5:9:15 speed ratios for EV applications. The proposed 45-phase IM drive with 90 stator slots is able to operate at five different pole-phase combinations, i.e., 45-phase 2-pole, 15-phase 6-pole, 9-phase 10-pole, 5-phase 18-pole and 3-phase 30-pole. The above five combinations make this MIM drive is suitable for EV applications, which eliminates the mechanical gear system in conventional EV. This can be helpful for saving the size and weight of the vehicle. This MIM drive offers the high torque for starting acceleration and gradient routes at low speeds and provides the high power for medium and high speed cruising, which is analogous to the typical five gear IC engine. The simulation of the 5hp 45-phase IM drive is verified with the help of Ansys Maxwell-2D (an electro-magnetic design tool) and Simplorer environment by co-simulating the FEM 2-D model.

1 February 2018 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
MAMadhukar Rao Airineni
Madhukar Rao Airineni
SKSivakumar Keerthipati
Sivakumar Keerthipati
In recent days, multilevel inverters are quite popular in the photovoltaic system to improve the power quality. One of the popular multilevel inverters for medium power applications is neutral point clamping inverter. However, with the limited number of switching combinations, energy balancing and fault‐tolerant operation is a major issue. The absence of energy balance mechanism may lead to unequal charge and discharge patterns in the batteries used in off‐grid applications, which in turn results in the un‐equal voltage at the batteries terminals. The difference in voltage between the sources can introduce the DC voltage offset at AC output, which causes serious problems when fed to the transformers or inductive loads like the induction motor. To address this problem, a five‐level inverter is proposed which is capable of energy balancing between the two DC sources, minimising the DC voltage offset and able to operate in some fault‐tolerant conditions. At the same time, this topology uses less number of switches as compared to conventional three‐phase five‐level inverters. The proposed topology is developed by combining conventional two‐level and three‐level inverters. The topology is verified by simulation using Matlab Simulink and tested on a laboratory prototype. The control algorithm for prototype is implemented with the help of Xilinx SPARTAN‐6 (XC6SLX9) FPGA board.

1 December 2016
Verified
Conference Paper
Closed access
MAMadhukar Rao A
Madhukar Rao A
MSManoranjan Sahoo
Manoranjan Sahoo
SKSivakumar K
Sivakumar K
A fault tolerant three phase five-level inverter configuration for the application of islanded photovoltaic (PV) systems is proposed. The fault tolerant five-level inverter configuration is achieved by stacking a two-level inverter, a three-level neutral point clamped inverter along with three bidirectional switches. This configuration is fed with two DC sources. The proposed configuration shows fault tolerant behavior towards switch open circuit fault in one or more inverter legs. In case of source failure it is able to utilize the healthier source for supplying uninterrupted power to essential loads. During fault the proposed fault tolerant inverter operates as three-level inverter with half of the rated power. The configuration also has the provision of energy balancing among two sources during partial shading or malfunctioning of PV system. The operation of the proposed inverter during different failure modes and energy balancing among two sources are discussed and verified using MATLAB/SIMULINK.

1 March 2015
Verified
Conference Paper
Closed access
ARA. Madhukar Rao
A. Madhukar Rao
NKN. Kiran Kumar
N. Kiran Kumar
KSK. Sivakumar
K. Sivakumar
A multi-level inverter configuration for 4n pole induction motor drive is presented in this paper. This topology is developed using three two-level inverters and two isolated dc sources. Among these three two-level inverters one inverter is switched at fundamental frequency and remaining two inverters are switched at higher frequency. Two isolated dc sources with equal magnitude are used in this topology to block the path for zero sequence currents. Low frequency operated inverter is connected to one dc source and high frequency operated inverters are connected to other dc source. The magnitude of dc source voltage required in this topology is four times lesser than the dc source required in conventional five-level NPC inverter configuration. The first center band harmonics are cancelled by providing 1800 phase shift between the high frequency carrier signals. This topology can be operated during the failure of any one inverter switches or any one dc source which will increase the reliability of the system. The number of switching devices used in this configuration is considerably less compared to conventional five-level inverters. This configuration is best suitable for high power applications where low frequency operated inverter can use thyristors as switching devices. The proposed topology is simulated in MATLAB/Simulink with (5HP) four pole induction motor and results are presented to show the validity of this configuration.