13 July 2015 in IEEE Transactions on Industrial Electronics
In this paper, a fault-tolerant single-phase five-level inverter configuration is proposed for photovoltaic (PV) generation systems. Conventional two-level inverters are popularly used in PV applications, but these inverters provide the output voltage with considerable harmonic content. One of the efficient ways to improve the power quality of PV generation systems is to replace a two-level inverter with a multilevel inverter. Conventional multilevel inverters reduce total harmonic distortion and filter requirements effectively, but it has limitations in terms of reliability due to increased device count and capacitor voltage balancing issues. Therefore, a fault-tolerant single-phase five-level inverter is presented, which is constructed by using a half-bridge two-level inverter, a three-level diode clamp inverter, and a bidirectional switch. The proposed inverter topology can tolerate the system faults due to failure of the source and/or switching devices with least modification in the switching combinations. It has less number of switching devices compared to conventional five-level inverters. The topology also has the energy-balancing capability between sources which helps in reducing uneven charge of batteries in case of partial shading or hotspots on one side of the PV panels. The proposed system under normal and faulty condition is simulated in MATLAB/Simulink environment, and results are verified with a laboratory prototype.
31 July 2017 in IEEE Transactions on Industrial Electronics
In this paper, a fault-tolerant multiphase multilevel inverter (MPMLI) configuration is proposed based on the dual inverter concept. This configuration helps to improve the performance of pole-phase modulated multiphase induction motor (PPMMIM) drive in both normal and switch failure conditions. Comparing to the existing multilevel inverter topologies for multiphase induction motor (MIM) drives, the proposed MPMLI configuration requires less number of dc sources and power electronic devices. The proposed MPMLI configuration is able to sustain under various faulty conditions, which can improve the reliability of the system. In addition, dc-link utilization (DLU) in low-pole mode is improved by using space vector pulsewidth modulation (SVPWM). In high-pole mode, carrier-phase-shifted 3-Φ SVPWM is used for reducing the torque ripple. This MPMLI configuration produces a multilevel voltage profile across the effective phase in 3-phase 12-pole mode. By maintaining the V/f ratio constant, the proposed MPMLI-fed MIM drive facilitates a wide range of load torque with half of the rated speed in faulty condition. This advantage makes it suitable for traction and electric vehicle applications where reliability and wide range of torque-speed are the major concerns. The performance of proposed MPMLI-fed 5 hp, 9-φ PPMMIM drive is simulated by finite-element method (FEM) in ANSYS Maxwell 2-D and experimentally verified by laboratory prototype under normal and faulty conditions.
1 February 2018 in IET Power Electronics
In recent days, multilevel inverters are quite popular in the photovoltaic system to improve the power quality. One of the popular multilevel inverters for medium power applications is neutral point clamping inverter. However, with the limited number of switching combinations, energy balancing and fault‐tolerant operation is a major issue. The absence of energy balance mechanism may lead to unequal charge and discharge patterns in the batteries used in off‐grid applications, which in turn results in the un‐equal voltage at the batteries terminals. The difference in voltage between the sources can introduce the DC voltage offset at AC output, which causes serious problems when fed to the transformers or inductive loads like the induction motor. To address this problem, a five‐level inverter is proposed which is capable of energy balancing between the two DC sources, minimising the DC voltage offset and able to operate in some fault‐tolerant conditions. At the same time, this topology uses less number of switches as compared to conventional three‐phase five‐level inverters. The proposed topology is developed by combining conventional two‐level and three‐level inverters. The topology is verified by simulation using Matlab Simulink and tested on a laboratory prototype. The control algorithm for prototype is implemented with the help of Xilinx SPARTAN‐6 (XC6SLX9) FPGA board.