Keerthipati Sivakumar

Keerthipati Sivakumar

Auto-generated profile, based on publicly available information

Keerthipati Sivakumar

Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Sangareddy, India

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MAMadhukar Rao. A
Madhukar Rao. A
KSK. Sivakumar
K. Sivakumar
In this paper, a fault-tolerant single-phase five-level inverter configuration is proposed for photovoltaic (PV) generation systems. Conventional two-level inverters are popularly used in PV applications, but these inverters provide the output voltage with considerable harmonic content. One of the efficient ways to improve the power quality of PV generation systems is to replace a two-level inverter with a multilevel inverter. Conventional multilevel inverters reduce total harmonic distortion and filter requirements effectively, but it has limitations in terms of reliability due to increased device count and capacitor voltage balancing issues. Therefore, a fault-tolerant single-phase five-level inverter is presented, which is constructed by using a half-bridge two-level inverter, a three-level diode clamp inverter, and a bidirectional switch. The proposed inverter topology can tolerate the system faults due to failure of the source and/or switching devices with least modification in the switching combinations. It has less number of switching devices compared to conventional five-level inverters. The topology also has the energy-balancing capability between sources which helps in reducing uneven charge of batteries in case of partial shading or hotspots on one side of the PV panels. The proposed system under normal and faulty condition is simulated in MATLAB/Simulink environment, and results are verified with a laboratory prototype.

4 April 2011 in IET Power Electronics
Verified
Journal Article
Closed access
SDS. De
S. De
DBD. Banerjee
D. Banerjee
KKK. Siva Kumar
K. Siva Kumar
KGK. Gopakumar
K. Gopakumar
RRRamchand Rijil
Ramchand Rijil
CPC. Patel
C. Patel
Multilevel inverters are an attractive solution in the medium-voltage and high-power applications. However in the low-power range also it can be a better solution compared to two-level inverters, if MOSFETs are used as devices switching in the order of 100 kHz. The effect of clamping diodes in the diode-clamped multilevel inverters play an important role in determining its efficiency. Power loss introduced by the reverse recovery of MOSFET body diode prohibits the use of MOSFET in hard-switched inverter legs. A technique of avoiding reverse recovery loss of MOSFET body diode in a three-level neutral point clamped inverter is suggested. The use of multilevel inverters topology enables operation at high switching frequency without sacrificing efficiency. High switching frequency of operation reduces the output filter requirement, which in turn helps in reducing the size of the inverter. This study elaborates the trade-off analysis to quantify the suitability of multilevel inverters in the low-power applications. Advantages of using a MOSFET-based three-level diode-clamped inverter for a PM motor drive and UPS systems are discussed.

10 July 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PRP. P. Rajeevan
P. P. Rajeevan
KSK. Sivakumar
K. Sivakumar
KGK. Gopakumar
K. Gopakumar
CPChintan Patel
Chintan Patel
Haitham Abu-RubHaitham Abu-Rub
Haitham Abu-Rub
A new scheme for nine-level voltage space-vector generation for medium-voltage induction motor (IM) drives with open-end stator winding is presented in this paper. The proposed nine-level power converter topology consists of two conventional three-phase two-level voltage source inverters powered by isolated dc sources and six floating-capacitor-connected H-bridges. The H-bridge capacitor voltages are effectively maintained at the required asymmetrical levels by employing a space vector modulation (SVPWM) based control strategy. An interesting feature of this topology is its ability to function in five- or three-level mode, in the entire modulation range, at full-power rating, in the event of any failure in the H -bridges. This feature significantly improves the reliability of the proposed drive system. Each leg of the three-phase two-level inverters used in this topology switches only for a half cycle of the reference voltage waveform. Hence, the effective switching frequency is reduced by half, resulting in switching loss reduction in high-voltage devices. The transient as well as the steady-state performance of the proposed nine-level inverter-fed IM drive system is experimentally verified in the entire modulation range including the overmodulation region.

8 February 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KSK. Sivakumar
K. Sivakumar
ADAnandarup Das
Anandarup Das
RRRamchand Rijil
Ramchand Rijil
CPChintan Patel
Chintan Patel
KGK. Gopakumar
K. Gopakumar
In this paper, a new five-level inverter topology for open-end winding induction-motor (IM) drive is proposed. The open-end winding IM is fed from one end with a two-level inverter in series with a capacitor-fed H-bridge cell, while the other end is connected to a conventional two-level inverter. The combined inverter system produces voltage space-vector locations identical to that of a conventional five-level inverter. A total of 2744 space-vector combinations are distributed over 61 space-vector locations in the proposed scheme. With such a high number of switching state redundancies, it is possible to balance the H-bridge capacitor voltages under all operating conditions including overmodulation region. In addition to that, the proposed topology eliminates 18 clamping diodes having different voltage ratings compared with the neutral point clamped inverter. On the other hand, it requires only one capacitor bank per phase, whereas the flying-capacitor scheme for a five-level topology requires more than one capacitor bank per phase. The proposed inverter topology can be operated as a three-level inverter for full modulation range, in case of any switch failure in the capacitor-fed H-bridge cell. This will increase the reliability of the system. The proposed scheme is experimentally verified on a four-pole 5-hp IM drive.

1 July 2007 in IET Electric Power Applications
Verified
Journal Article
Closed access
VSV.T. Somasekhar
V.T. Somasekhar
SSS. Srinivas
S. Srinivas
BRB. Prakash Reddy
B. Prakash Reddy
CRCh. Nagarjuna Reddy
Ch. Nagarjuna Reddy
KSK. Sivakumar
K. Sivakumar
Three-level inversion can be achieved with dual two-level inverters feeding an open-end winding induction motor. A space vector-based pulse width-modulated (PWM) switching scheme is proposed, which achieves three-level inversion using all the space vector locations with a single DC power supply. The zero-sequence current is reduced by reducing the zero-sequence voltage to zero, in the average sense, within a sampling time interval. The proposed PWM scheme balances the zero-sequence current dynamically, simply with a relocation of the effective time within a sampling time interval. The switching frequency of the inverters is also reduced to half as only one inverter is switched while the other is clamped in a sampling time interval. Also, the proposed PWM scheme employs only the three instantaneous phase reference voltages obviating the necessity of sector identification and lookup tables.

25 November 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GMGopal Mondal
Gopal Mondal
KSK. Sivakumar
K. Sivakumar
RRRamchand Rijil
Ramchand Rijil
KGK. Gopakumar
K. Gopakumar
ELEmil Levi
Emil Levi
This paper develops a seven-level inverter structure for open-end winding induction motor drives. The inverter supply is realized by cascading four two-level and two three-level neutral-point-clamped inverters. The inverter control is designed in such a way that the common-mode voltage (CMV) is eliminated. DC-link capacitor voltage balancing is also achieved by using only the switching-state redundancies. The proposed power circuit structure is modular and therefore suitable for fault-tolerant applications. By appropriately isolating some of the inverters, the drive can be operated during fault conditions in a five-level or a three-level inverter mode, with preserved CMV elimination and DC-link capacitor voltage balancing, within a reduced modulation range.