Qinghai Huang

Qinghai Huang

Auto-generated profile, based on publicly available information

Qinghai Huang

Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JLJian-Min Liu
Jian-Min Liu
YZYu Zhou
Yu Zhou
YLY. Li
Y. Li
TLT. Li
T. Li
BLB. Leng
B. Leng
KZKaijun Zhao
Kaijun Zhao
BACKGROUND AND PURPOSE: Although flow diverters have been reported with favorable clinical and angiographic outcomes in various literatures, randomized trials determining their true effectiveness and safety are still in lack. The Parent Artery Reconstruction for Large or Giant Cerebral Aneurysms Using the Tubridge Flow Diverter (PARAT) trial was designed to evaluate the safety and efficacy of the Tubridge flow diverter in the treatment of large or giant aneurysms in comparison with Enterprise stent-assisted coiling. MATERIALS AND METHODS: This prospective, multicenter, randomized trial was conducted at 12 hospitals throughout China. Enrolled adults with unruptured large/giant intracranial aneurysms were randomly assigned (1:1) to receive either Enterprise stent-assisted coiling or Tubridge flow diverter implantation. The primary end point was complete occlusion at 6-month follow-up, while secondary end points included technical success, mortality, target vessel–related stroke, aneurysm bleeding, in-stent stenosis, parent artery occlusion, and the frequency of all adverse events. RESULTS: Among 185 enrolled subjects, 41 withdrew before procedure initiation. Overall, 82 subjects underwent Tubridge implantation, and 62 subjects were primarily treated with stent-assisted coiling. The results of 6-month follow-up imaging included complete occlusion rates of 75.34% versus 24.53% for the Tubridge and stent-assisted coiling groups, respectively, with a calculated common odds ratio of 9.4 (95% confidence interval, 4.14–21.38; P < .001). There was a higher, nonsignificant frequency of complications for Tubridge subjects. Multivariate analysis showed a decreased stroke rate at the primary investigational site, with a marginal P value (P = .051). CONCLUSIONS: This trial showed an obviously higher rate of large and giant aneurysm obliteration with the Tubridge FD over Enterprise stent-assisted coiling. However, this higher obliteration rate came at the cost of a nonsignificantly higher rate of complications. Investigational site comparisons suggested that a learning curve for flow-diverter implantation should be recognized and factored into trial designs.

31 January 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JXJinyu Xu
Jinyu Xu
YYYing Yu
Ying Yu
XWXi Wu
Xi Wu
YWYongfa Wu
Yongfa Wu
CJChe Jiang
Che Jiang
JLJian-Min Liu
Jian-Min Liu
Hemodynamic factors are commonly believed to play an important role in the pathogenesis, progression, and rupture of cerebral aneurysms. In this study, we aimed to identify significant hemodynamic and morphological parameters that discriminate intracranial aneurysm rupture status using 3-dimensional-angiography and computational fluid dynamics technology. 3D-DSA was performed in 8 patients with mirror posterior communicating artery aneurysms (Pcom-MANs). Each pair was divided into ruptured and unruptured groups. Five morphological and three hemodynamic parameters were evaluated for significance with respect to rupture. The normalized mean wall shear stress (WSS) of the aneurysm sac in the ruptured group was significantly lower than that in the unruptured group (0.52±0.20 versus 0.81±0.21, P = .012). The percentage of the low WSS area in the ruptured group was higher than that in the unruptured group (4.11±4.66% versus 0.02±0.06%, P = .018). The AR was 1.04±0.21 in the ruptured group, which was significantly higher than 0.70±0.17 in the unruptured group (P = .012). By contrast, parameters that had no significant differences between the two groups were OSI (P = .674), aneurysm size (P = .327), size ratio (P = .779), vessel angle (P = 1.000) and aneurysm inclination angle (P = 1.000). Pcom-MANs may be a useful disease model to investigate possible causes of aneurysm rupture. The ruptured aneurysms manifested lower WSS, higher percentage of low WSS area, and higher AR, compared with the unruptured one. And hemodynamics is as important as morphology in discriminating aneurysm rupture status.

10 April 2014 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
YZY. Zhou
Y. Zhou
PYP.-F. Yang
P.-F. Yang
YFY.-B. Fang
Y.-B. Fang
YXY. Xu
Y. Xu
BHB. Hong
B. Hong
JLJian-Min Liu
Jian-Min Liu
BACKGROUND AND PURPOSE: The Tubridge flow diverter is a novel device developed in China and aimed at reconstructing the parent artery and occluding the aneurysm. We conducted this study to evaluate its feasibility, safety, and efficacy for the treatment of large or giant internal carotid artery aneurysms, which are still challenging with conventional therapy. MATERIALS AND METHODS: The clinical and angiographic data of 28 patients with 28 large or giant internal carotid artery aneurysms treated with Tubridge flow diverters were prospectively collected and analyzed. RESULTS: Thirty-three Tubridge flow diverters were successfully implanted except for 1 poor midstent opening; the result was a technical success rate of 97.0% (32/33). Follow-up angiographies were available for 25 aneurysms; the mean follow-up was 9.9 months (5–24 months). Of the 25 aneurysms, 18 (72.0%) were completely occluded, 6 (24.0%) were improved, and 1 (4.0%) was unchanged. All of the visible covered branches and parent arteries were patent, with no stenosis or obliteration. During a follow-up of 6–30 months (mean, 19 months), symptoms were resolved in 13 patients, improved in 6 patients, and unchanged in 4 patients. Five patients experienced transient clinical deterioration due to a postoperative increased mass effect. Procedure-related morbidity and mortality were both zero. CONCLUSIONS: Our preliminary experience shows that the Tubridge flow diverter is a safe and effective tool for treating large and giant internal carotid artery aneurysms. However, multicenter randomized trials and studies involving a long-term follow-up are necessary.

1 October 2018 in World Neurosurgery
Verified
Journal Article
Closed access
DZDeyuan Zhu
Deyuan Zhu
YYYazhou Yan
Yazhou Yan
PZPuyuan Zhao
Puyuan Zhao
GDGuoli Duan
Guoli Duan
RZRui Zhao
Rui Zhao
QHQinghai Huang
Qinghai Huang

1 January 2019 in European Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
YLYin Luo
Yin Luo
HTHaishuang Tang
Haishuang Tang
HLHe Li
He Li
RZRui Zhao
Rui Zhao
QHQinghai Huang
Qinghai Huang
JLJian-Min Liu
Jian-Min Liu

1 September 2016 in World Neurosurgery
Verified
Journal Article
Closed access
MFMing-Tao Feng
Ming-Tao Feng
WWWan-Ling Wen
Wan-Ling Wen
ZFZheng-Zhe Feng
Zheng-Zhe Feng
YFYi-Bin Fang
Yi-Bin Fang
JLJian-Min Liu
Jian-Min Liu
QHQing-Hai Huang
Qing-Hai Huang