Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.
Objective: To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. Design: Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arterial CO2 (Paco 2), transcutaneous CO2 (TcPco 2), and end tidal CO2 (Petco 2) were analysed. The Bland-Altman method was used to assess bias and repeatability. Results: Petco 2 correlated strongly with Paco 2 and TcPco 2. However, Petco 2 underestimated Paco 2 at a clinically unacceptable level (mean (SD) 1.1 (0.70) kPa) and did not trend reliably over time within individual subjects. The Petco 2 bias was independent of Paco 2 and severity of lung disease. Conclusions: Petco 2 had an unacceptable under-recording bias. TcPco 2 should currently be considered the preferred method of non-invasive CO2 monitoring for neonatal transport.
15 February 2006 in American Journal of Respiratory and Critical Care Medicine
Rationale: The importance of applying high-frequency oscillatory ventilation with a high lung volume strategy in infants is well established. Currently, a lack of reliable methods for assessing lung volume limits clinicians' ability to achieve the optimum volume range. Objectives: To map the pressure–volume relationship of the lung during high-frequency oscillatory ventilation in infants, to determine at what point ventilation is being applied clinically, and to describe the relationship between airway pressure, lung volume, and oxygenation. Methods: In 12 infants, a partial inflation limb and the deflation limb of the pressure–volume relationship were mapped using a quasi-static lung volume optimization maneuver. This involved stepwise airway pressure increments to total lung capacity, followed by decrements until the closing pressure of the lung was identified. Measurements and Main Results: Lung volume and oxygen saturation were recorded at each airway pressure. Lung volume was measured using respiratory inductive plethysmography. A distinct deflation limb could be mapped in each infant. Overall, oxygenation and lung volume were improved by applying ventilation on the deflation limb. Maximal lung volume and oxygenation occurred on the deflation limb at a mean airway pressure of 3 and 5 cm H2O below the airway pressure approximating total lung capacity, respectively. Conclusions: Using current ventilation strategies, all infants were being ventilated near the inflation limb. It is possible to delineate the deflation limb in infants receiving high-frequency oscillatory ventilation; in doing so, greater lung volume and oxygenation can be achieved, often at lower airway pressures.
1 September 2019 in American Journal of Respiratory and Critical Care Medicine
Rationale: The preterm lung is susceptible to injury during transition to air-breathing at birth. It remains unclear whether rapid or gradual lung aeration at birth causes less lung injury. Objectives: To examine the effect of gradual and rapid aeration at birth on 1) the spatiotemporal volume conditions of the lung, and 2) resultant regional lung injury. Methods: 125±1d gestation preterm lambs were randomised at birth to receive 1) tidal ventilation without an intentional recruitment (No-RM; n=19), 2) sustained inflation (SI) until full aeration (n=26), or 3) tidal ventilation with an initial escalating/de-escalating positive end-expiratory pressure (DynPEEP; n=26). Ventilation thereafter continued for 90 min at standardised settings including positive end-expiratory pressure 8 cmH2O. Lung mechanics and regional aeration and ventilation (electrical impedance tomography) were measured throughout and correlated with histological and gene markers of early lung injury. Measurements and Main Results: DynPEEP significantly improved dynamic compliance (p<0.0001). A SI, but not DynPEEP or No-RM, resulted in preferential non-dependent lung aeration, that became less uniform with time (p=0.0006). The non-dependent lung was preferential ventilated by 5 min in all groups, with ventilation only becoming uniform with time in the No-RM and DynPEEP groups. All strategies generated similar non-dependent lung injury patterns. Only a SI caused greater upregulation of dependent lung gene markers compared to unventilated fetal controls (p<0.05). Conclusions: Rapidly aerating the preterm lung at birth creates heterogeneous volume states, producing distinct regional injury patterns that affect subsequent tidal ventilation. Gradual aeration with tidal ventilation and PEEP produced the least lung injury.
Continuous positive airway pressure and surfactant represent the first- and second-line treatment for respiratory distress syndrome in preterm neonates, as European and American guidelines, since 2013 and 2014, respectively, started to recommend surfactant replacement only when continuous positive airway pressure fails. These recommendations, however, are not personalized to the individual physiopathology. Simple clinical algorithms may have improved the diffusion of neonatal care, but complex medical issues can hardly be addressed with simple solutions. The treatment of respiratory distress syndrome is a complex matter and can be only optimized with personalization. We performed a review of tools to individualize the management of respiratory distress syndrome based on physiopathology and actual patients’ need, according to precision medicine principles. Advanced oxygenation metrics, lung ultrasound, electrical impedance tomography, and both quantitative and qualitative surfactant assays were examined. When these techniques were investigated with diagnostic accuracy studies, reliability measures have been meta-analysed. Amongst all these tools, quantitative lung ultrasound seems the more developed for the widespread use and has a higher diagnostic accuracy (meta-analytical AUC = 0.952 [95% CI: 0.951–0.953]). Surfactant adsorption (AUC = 0.840 [95% CI: 0.824–0.856]) and stable microbubble test (AUC = 0.800 [95% CI: 0.788–0.812]) also have good reliability, but need further industrial development. We advocate for a more accurate characterization and a personalized approach of respiratory distress syndrome. With the above-described currently available tools, it should be possible to personalize the treatment of respiratory distress syndrome according to physiopathology.