25 November 2014 in Clinical & Experimental Ophthalmology
11 April 2024 in Australian Critical Care
1 February 2018 in Optometry and Vision Science
SIGNIFICANCE: This article shows that self‐tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self‐tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma‐specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty‐seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self‐measured IOP on 118 (±29) occasions for 40 (±7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period ( r 2 = 0.82, P <. 0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (±5.2) to 16.1 (±2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self‐tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
1 December 2019 in American Journal of Ophthalmology
To develop location-specific models of normal, age-related changes in the macular ganglion cell layer (GCL) from optical coherence tomography (OCT). Using these OCT-derived models, we predicted visual field (VF) sensitivities and compared these results to actual VF sensitivities. Retrospective cohort study. Single eyes of 254 normal participants were retrospectively enrolled from the Centre for Eye Health (Sydney, Australia). Macular GCL measurements were obtained using Spectralis OCT. Cluster algorithms were performed to identify spatial patterns demonstrating similar age-related change. Quadratic and linear regression models were subsequently used to characterize age-related GCL decline. Forty participants underwent additional testing with Humphrey VFs, and 95% prediction intervals were calculated to measure the predictive ability of structure-function models incorporating cluster-based pooling, age correction, and consideration of spatial summation. Quadratic GCL regression models provided a superior fit (P value <.0001-.0066), establishing that GCL decline commences in the late 30s across the macula. The equivalent linear rates of GCL decline showed eccentricity-dependent variation (0.13 μm/yr centrally vs 0.06 μm/yr peripherally); however, average, normalized GCL loss per year was consistent across the 64 macular measurement locations at 0.26%. The 95% prediction intervals describing predicted VF sensitivities were significantly narrower across all cluster-based structure-function models (3.79-4.99 dB) compared with models without clustering applied (5.66-6.73 dB, P < .0001). Combining spatial clustering with age-correction based on regression models allowed the development of robust models describing GCL changes with age. The resultant superior predictive ability of VF sensitivity from ganglion cell measurements may be applied to future models of disease development to improve detection of early macular GCL pathology.
1 April 2018 in Investigative Ophthalmology & Visual Science
Purpose: To investigate the effect of stimulus size and disease status on the structure-function relationship within the central retina, we correlated the differential light sensitivity (DLS) with Goldmann stimulus size I to V (GI–V) and optical coherence tomography (OCT) derived in vivo ganglion cell count per stimulus area (GCc) within the macular area in normal subjects and patients with early glaucoma. Methods: Humphrey Field Analyzer 10–2 visual field data with GI through V and Spectralis OCT macular ganglion cell layer (GCL) thickness measurements were collected from normal and early glaucoma cohorts including 25 subjects each. GCc was calculated from GCL thickness data and correlated with DLSs for different stimulus sizes. Results: Correlation coefficients attained with smaller stimulus size were higher compared to larger stimulus sizes in both normal (GI–GII: R2 = 0.41–0.43, GIII–GV: R2 = 0.16–0.41) and diseased cohorts (GI–GII: R2 = 0.33–0.41, GIII–GV: R2 = 0.19–0.36). Quadratic regression curves for combined GI to V data demonstrated high correlation (R2= 0.82–0.90) and differed less than 1 dB of visual sensitivity within the GCc range between cohorts. The established structure-function relationship was compatible with a histologically derived model correlation spanning the range predicted by stimulus sizes GI to GIII. Conclusions: Stimulus sizes within critical spatial summation area (GI–II) improved structure-function correlations in the central visual field. The structure-function relationship was identical in both normal and diseased cohort when GI to GV data were combined. Congruency of GI and GII structure-function correlation with those previously derived with GIII from more peripheral locations further suggests that the structure-function relationship is governed by the number of ganglion cell per stimulus area.
7 August 2014 in Ophthalmic and Physiological Optics