Tobias Meißner

Tobias Meißner

Auto-generated profile, based on publicly available information

Tobias Meißner

Institute of Biomedical Engineering, Karlsruhe Institute of Technology Electrical Engineering and Information Technology, Fritz-Haber-Weg 1, Karlsruhe, Baden-Württemberg, 76131, GERMANY

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
TMTobias Meißner
Tobias Meißner
LCLaura Antonia Cerbone
Laura Antonia Cerbone
PRPaolo Russo
Paolo Russo
WNWerner Nahm
Werner Nahm
JHJürgen W. Hesser
Jürgen W. Hesser
Objective. 3D-localization of gamma sources has the potential to improve the outcome of radio-guided surgery. The goal of this paper is to analyze the localization accuracy for point-like sources with a single coded aperture camera. Approach. We both simulated and measured a point-like 241 Am source at 17 positions distributed within the field of view of an experimental gamma camera. The setup includes a 0.11 mm thick Tungsten sheet with a MURA mask of rank 31 and pinholes of 0.08 mm in diameter and a detector based on the photon counting readout circuit Timepix3. Two methods, namely an iterative search including either a symmetric Gaussian fitting or an exponentially modified Gaussian fitting (EMG) and a center of mass method were compared to estimate the 3D source position. Main results. Considering the decreasing axial resolution with source-to-mask distance, the EMG improved the results by a factor of 4 compared to the Gaussian fitting based on the simulated data. Overall, we obtained a mean localization error of 0.77 mm on the simulated and 2.64 mm on the experimental data in the imaging range of 20 − 100 mm . Significance. This paper shows that despite the low axial resolution, point-like sources in the nearfield can be localized as well as with more sophisticated imaging devices such as stereo cameras. The influence of the source size and the photon count on the imaging and localization accuracy remains an important issue for further research.

21 March 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
TMTobias Meißner
Tobias Meißner
LCLaura Antonia Cerbone
Laura Antonia Cerbone
PRPaolo Russo
Paolo Russo
WNWerner Nahm
Werner Nahm
JHJürgen Hesser
Jürgen Hesser
Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization due to their high sensitivity and the possibility of 3D imaging. We evaluated the axial resolution and computational performance of two reconstruction methods. Methods: An experimental gamma camera was set up consisting of the pixelated semiconductor detector Timepix3 and MURA mask of rank 31 with round holes of 0.08 mm in diameter in a 0.11 mm thick Tungsten sheet. A set of measurements was taken where a point-like gamma source was placed centrally at 21 different positions within the range of 12–100 mm. For each source position, the detector image was reconstructed in 0.5 mm steps around the true source position, resulting in an image stack. The axial resolution was assessed by the full width at half maximum (FWHM) of the contrast-to-noise ratio (CNR) profile along the z-axis of the stack. Two reconstruction methods were compared: MURA Decoding and a 3D maximum likelihood expectation maximization algorithm (3D-MLEM). Results: While taking 4400 times longer in computation, 3D-MLEM yielded a smaller axial FWHM and a higher CNR. The axial resolution degraded from 5.3 mm and 1.8 mm at 12 mm to 42.2 mm and 13.5 mm at 100 mm for MURA Decoding and 3D-MLEM respectively. Conclusion: Our results show that the coded aperture enables the depth estimation of single point-like sources in the near field. Here, 3D-MLEM offered a better axial resolution but was computationally much slower than MURA Decoding, whose reconstruction time is compatible with real-time imaging.

14 June 2023 in arXiv
Verified
Preprint
Open access
PDF file
TMTobias Meißner
Tobias Meißner
WNWerner Nahm
Werner Nahm
JHJürgen W. Hesser
Jürgen W. Hesser
NLNikolas Löw
Nikolas Löw
Coded Aperture Imaging (CAI) has been proposed as an alternative collimation technique in nuclear imaging. To maximize spatial resolution small pinholes in the coded aperture mask are required. However, a high-resolution detector is needed to correctly sample the point spread function (PSF) to keep the Nyquist-Shannon sampling theorem satisfied. The disadvantage of smaller pixels, though, is the resulting higher Poisson noise. Thus, the aim of this paper was to investigate if sufficiently accurate CAI reconstruction is achievable with a detector which undersamples the PSF. With the Monte Carlo simulation framework TOPAS a test image with multiple spheres of different diameter was simulated based on the setup of an experimental gamma camera from previous work. Additionally, measured phantom data were acquired. The captured detector images were converted to low-resolution images of different pixel sizes according to the super-resolution factor $k$. Multiple analytical reconstruction methods and a Machine Learning approach were compared based on the contrast-to-noise ratio (CNR). We show, that all reconstruction methods are able to reconstruct both the test image and the measured phantom data for $k \leq 7$. With a synthetic high-resolution PSF and upsampling the simulated low-resolution detector image by bilinear interpolation the CNR can be kept approximately constant. Results of this simulation study and additional validation on measured phantom data indicate that an undersampling detector can be combined with small aperture holes. However, further experiments need to be conducted.