We designed a prototype compact gamma camera (MediPROBE4) for nuclear medicine tasks, including radio-guided surgery and sentinel lymph node imaging with a 99mTc radiotracer. We performed Monte Carlo (MC) simulations for image performance assessment, and first spectroscopic imaging tests with a 300 μm thick silicon detector. The hand-held camera (1 kg weight) is based on a Timepix4 readout circuit for photon-counting, energy-sensitive, hybrid pixel detectors (24.6 × 28.2 mm2 sensitive area, 55 μm pixel pitch), developed by the Medipix4 Collaboration. The camera design adopts a CdTe detector (1 or 2 mm thick) bump-bonded to a Timepix4 readout chip and a coded aperture collimator with 0.25 mm diameter round holes made of 3D printed 1-mm thick tungsten. Image reconstruction is performed via autocorrelation deconvolution. Geant4 MC simulations showed that, for a 99mTc source in air, at 50 mm source-collimator distance, the estimated collimator sensitivity (4 × 10-4) is 292 times larger than that of a single hole in the mask; the system sensitivity is 0.22 cps/kBq (2 mm CdTe); the lateral spatial resolution is 1.7 mm FWHM. The estimated axial longitudinal resolution is 8.2 mm FWHM at 40 mm distance. First experimental tests with a 300 μm thick Silicon pixel detector bump-bonded to a Timepix4 chip and a high-resolution coded aperture collimator showed time-over-threshold and time-of-arrival capabilities with 241Am and 133Ba gamma-ray sources. MC simulations and validation lab tests showed the expected performance of the MediPROBE4 compact gamma camera for gamma-ray 3D imaging.

28 April 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LCLaura Antonia Cerbone
Laura Antonia Cerbone
GMGiovanni Mettivier
Giovanni Mettivier
Youfang LaiYoufang Lai
Youfang Lai
XJXun Jia
Xun Jia
SBSteven Kyle Boyd
Steven Kyle Boyd
PRPaolo Russo
Paolo Russo
Objective. To obtain maps of absorbed dose and an estimate of the effective dose to an adult patient for a high resolution peripheral quantitative computed tomography (HR-pQCT) (XtremeCT II) examination of the distal tibia and radius, using a graphical processing unit (GPU)-based Monte Carlo (MC) code. Approach. We adapted the validated code gCTD (GPU-based CT Dose calculator), to replicate the HR-pQCT configuration. MC simulations were performed on digital phantoms of the tibia and radius obtained from bilateral scans of the ankle and wrist of a 25 year-old female volunteer. Scans were segmented using an ad hoc algorithm in Fiji. Simulations run on an NVIDIA GeForce RTX 3090 GPU board. MC dose estimates were validated via computed tomography dose index measurements. Main Results. We obtained the absorbed dose distribution in the skin, bone, bone marrow, fat, and muscle tissues. The effective dose for the HR-pQCT examination were 2.05 μSv and 2.13 μSv for the right and left tibia, and 1.48 μSv and 1.49 μSv for the right and left radius, respectively, with a Type A statistical uncertainty of 0.06% (k = 3) with 4.66 × 1011 photon histories. Corresponding effective dose conversion coefficients (k-factors) were 0.185 μSv ∙ mGy−1 · cm−1 (tibia), and 0.133 μSv mGy−1 · cm−1 (radius). Significance. We reported the first independent estimate of the effective dose for standard HR-pQCT clinical scans of the distal tibia and radius with the XtremeCT II scanner. Effective dose estimates (considering a total relative uncertainty of less than 40%) were lower than those indicated by the manufacturer and commonly reported for these scans. With 4.66 × 109 photon histories, the gCTD MC code can produce 3D dose maps from segmented HR-pQCT images in less than 12 s (GPU time), with 0.9% (k = 3) statistical uncertainty, making real-time personalized dose estimate feasible.

23 October 2025 in Physica Medica
Verified
Journal Article
Open access
LCLaura Antonia Cerbone
Laura Antonia Cerbone
The recent acquisition of the first-ever hand radiography in low Earth orbit marked a milestone for X-ray imaging in space, motivating further research for the development of space-adapted devices. This review intends to provide an overview of the current state of X-ray imaging technologies for space applications, analysed within the framework of astronauts' healthcare assessment, highlighting the role of medical physicists in advancing this field. An initial search was conducted on PubMed using keywords related to radiography and spaceflight. A further selection was performed by screening the reference lists of pertinent papers that emerged in the initial search. This review shows medical conditions that may pose risks to astronauts during spaceflight and could benefit from X-ray imaging for diagnosis or treatment. Currently available technology for in-flight X-ray imaging is presented. Gender-specific aspects have been considered. Critical aspects identified include device limitations, sources of image deterioration, the need for quality assessment and dosimetry studies. A strong interest in the use of radiography in space emerged. However, to date, only one radiographic image has been acquired in low Earth orbit. Further research is needed to identify adequate hardware and to investigate the feasibility, image quality, and radiation dose for in-flight radiographic imaging. Quality assurance procedures should possibly be adapted to the space environment. The role of medical physicists in this context is central, and specific attention to this field is desirable to address the challenges outlined.

15 July 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
TMTobias Meißner
Tobias Meißner
LCLaura Antonia Cerbone
Laura Antonia Cerbone
PRPaolo Russo
Paolo Russo
WNWerner Nahm
Werner Nahm
JHJürgen W. Hesser
Jürgen W. Hesser
Objective. 3D-localization of gamma sources has the potential to improve the outcome of radio-guided surgery. The goal of this paper is to analyze the localization accuracy for point-like sources with a single coded aperture camera. Approach. We both simulated and measured a point-like 241 Am source at 17 positions distributed within the field of view of an experimental gamma camera. The setup includes a 0.11 mm thick Tungsten sheet with a MURA mask of rank 31 and pinholes of 0.08 mm in diameter and a detector based on the photon counting readout circuit Timepix3. Two methods, namely an iterative search including either a symmetric Gaussian fitting or an exponentially modified Gaussian fitting (EMG) and a center of mass method were compared to estimate the 3D source position. Main results. Considering the decreasing axial resolution with source-to-mask distance, the EMG improved the results by a factor of 4 compared to the Gaussian fitting based on the simulated data. Overall, we obtained a mean localization error of 0.77 mm on the simulated and 2.64 mm on the experimental data in the imaging range of 20 − 100 mm . Significance. This paper shows that despite the low axial resolution, point-like sources in the nearfield can be localized as well as with more sophisticated imaging devices such as stereo cameras. The influence of the source size and the photon count on the imaging and localization accuracy remains an important issue for further research.

19 January 2024 in arXiv
Verified
Preprint
Open access
PDF file
TMTobias Meißner
Tobias Meißner
LCLaura Antonia Cerbone
Laura Antonia Cerbone
PRPaolo Russo
Paolo Russo
WNWerner Nahm
Werner Nahm
JHJürgen W. Hesser
Jürgen W. Hesser
Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization due to their high sensitivity and the possibility of 3D imaging. We evaluated the axial resolution and computational performance of two reconstruction methods. Methods: An experimental gamma camera was set up consisting of the pixelated semiconductor detector Timepix3 and MURA mask of rank $31$ with round holes of $0.08$mm in diameter in a $0.11$mm thick Tungsten sheet. A set of measurements was taken where a point-like gamma source was placed centrally at $21$ different positions within the range of $12$ to $100$mm. For each source position, the detector image was reconstructed in $0.5$mm steps around the true source position, resulting in an image stack. The axial resolution was assessed by the full width at half maximum (FWHM) of the contrast-to-noise ratio (CNR) profile along the z-axis of the stack. Two reconstruction methods were compared: MURA Decoding and a 3D maximum likelihood expectation maximization algorithm (3D-MLEM). Results: While taking $4{,}400$ times longer in computation, 3D-MLEM yielded a smaller axial FWHM and a higher CNR. The axial resolution degraded from $5.3$mm and $1.8$mm at $12$mm to $42.2$mm and $13.5$mm at $100$mm for MURA Decoding and 3D-MLEM respectively. Conclusion: Our results show that the coded aperture enables the depth estimation of single point-like sources in the near field. Here, 3D-MLEM offered a better axial resolution but was computationally much slower than MURA Decoding, whose reconstruction time is compatible with real-time imaging.

28 March 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
UCUmberto Crimaldi
Umberto Crimaldi
NLNastassja Luongo
Nastassja Luongo
LCLaura Antonia Cerbone
Laura Antonia Cerbone
RPRoberto Pacelli
Roberto Pacelli
PRPaolo Russo
Paolo Russo
GMGiovanni Mettivier
Giovanni Mettivier
Spatially fractionated radiotherapy with X-ray minibeams (x-MBRT) aims to increase normal-tissue tolerance by delivering alternating high- and low-dose regions. We provide a Monte Carlo-based framework to design and optimize multi-slit collimators, quantifying how geometry and material govern peak–valley modulation. A validated digital twin of the SmART X-RAD225Cx irradiator was implemented in TOPAS/Geant4. Various x-MBRT collimators were simulated with parallel or divergent slits. The parameter space covered a slit width w (0.1–0.9 mm), center-to-center spacing CTC (1–3 mm), thickness T (1–5 mm), and acceptance angle θ. Dose was scored in a 2 × 2 × 2 cm3 water phantom at a 1 cm depth. For fixed w/CTC, peak-valley dose ratio PVDR increases with larger CTC via an increase in peak dose, with the valley dose nearly constant. Peak transmission saturated at θ ≈ 3°, indicating minimal benefit from larger acceptance. Divergent slits yielded flatter lateral profiles but higher valley doses than parallel slits, reducing PVDR around the central axis. This Monte Carlo study provides insights for optimizing collimator geometries in x-MBRT using small-animal irradiators, informing the design of more effective collimation systems to enhance treatment precision and normal-tissue sparing.