Anshuman Mohapatra

Anshuman Mohapatra

Auto-generated profile, based on publicly available information

Anshuman Mohapatra

Department of Physics, Case Western Reserve University, 2076 Adelbert Road, Cleveland, Ohio 44106, United States

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
AMAnshuman Mohapatra
Anshuman Mohapatra
SLSowmya Bekshe Lokappa
Sowmya Bekshe Lokappa
NCNitin Chaudhary
Nitin Chaudhary

22 February 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
VVVignesh Venkataramani
Vignesh Venkataramani
DLDanielle R. Latham
Danielle R. Latham
RARamita Arampongpun
Ramita Arampongpun
MZMarouen Zammali
Marouen Zammali
TSTejasvin Shrikanth
Tejasvin Shrikanth
LKLydia Kisley
Lydia Kisley
Understanding biophysical phenomena requires techniques that access biologically relevant spatial and temporal scales. Expansion Microscopy (ExM) is a sample preparation approach which achieves super-resolution spatial scales by leveraging osmotic forces in a swellable hydrogel to physically separate structures to distances larger than the diffraction limit of light. Yet, in traditional osmotic ExM only pre- and post- expanded samples can be imaged. Further, fragmentation, hydrogel deformation, and signal loss are common while requiring samples to be chemically fixed. Therefore, there is little control of the expansion, reproducibility can be challenging, and dynamics of biological samples at applicable temporal scales cannot be observed. Here, we develop Tensile Expansion Microscopy (TExM) to mechanically expand fixed and, notably, living cellular samples. Highly-stretchable and tough double network alginate- Ca 2+ /polyacrylamide hydrogels are expanded by tensile forces applied using an electromechanical iris expansion device during continuous imaging on a fluorescence microscope. We incorporate two-photon polymerized microscale fluorescent fiducial markers to track samples and distortion during expansion. The hydrogels controllably and repeatedly expand up to 3.3× with distortions less than 12 µm across 1.3 mm 2 . TExM is first applied to fixed NIH 3T3 fibroblast cells with immunohistochemistry-stained microtubules, achieving super-resolutions of 100 nm. Then, TExM is demonstrated with living HeLa cells with internal fluorescent reporters showing increased cell size and cell-to-cell separation under 3.2× linear expansion. Overall, TExM allows for continuous, stepwise, and precise temporal modulation of lateral substrate strain, enabling real time monitoring of dynamics of both fixed and viable live cell processes at higher spatial resolutions. TExM can further investigate broad biophysical questions due to its compatibility with other analytical imaging methods that are sensitive to water or fixatives used in traditional osmotic ExM.

12 June 2026 in ACS Sensors
Verified
Journal Article
Open access
AMAnshuman Mohapatra
Anshuman Mohapatra
JAJeanpun Antarasen
Jeanpun Antarasen
DLDanielle R. Latham
Danielle R. Latham
MBMarisa A. Barilla
Marisa A. Barilla
CDCaitlin M. Davis
Caitlin M. Davis
LKLydia Kisley
Lydia Kisley
The cellular cytosol is a crowded environment. Biomolecular Förster resonance energy transfer (FRET) sensors have been developed to measure crowding in cytosol mimics composed of synthetic polymers such as polyethylene glycol (PEG) and Ficoll that impart an excluded volume effect. We investigate the PEG-driven phase separation of a protein crowding sensor, AcGFP1/mCherry-FRET crowding helix 2 (CrH2), into fluorescent puncta compared to a DNA-based crowding sensor (CrD) with an Alexa488/Cy5 FRET pair that did not form observable puncta under the same crowding conditions of 100-400 mg/mL 8 kDa PEG. Using fluorescence recovery after photobleaching imaging, we uncover the liquid-like physical properties of the PEG-induced puncta. Two-color fluorescence microscopy imaging reveals crowder-induced inhomogeneity, concentration variations, and partition coefficients across the dilute and dense phases of the liquid puncta, which remain largely underexplored in bulk fluorometry measurements. Thus, the average crowding sensor response may originate from an aqueous biphasic system, reporting an erroneous average response instead of distinct levels of crowdedness. A comparison of excluded volume effects conferred by Ficoll and PEGs of various molecular weights shows the influence of size, concentration, excluded volume, and chemical composition on the CrH2 sensor response. We demonstrate that ≥18% PEG (w/v) was sufficient to enable the phase separation of CrH2 and alter sensor response through a mechanism that may be driven by polymer interactions with the flexible hinge region. We also show that CrD can form fluorescence puncta upon charge-neutralization with poly-l-lysine. Thus, our study emphasizes the need to probe crowding environments with orthogonal sensors.