Jeanpun Antarasen

Jeanpun Antarasen

Auto-generated profile, based on publicly available information

Jeanpun Antarasen

Department of Physics, Case Western Reserve University, 2076 Adelbert Road, Cleveland, Ohio 44106, United States

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2024 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
SKStephanie N. Kramer
Stephanie N. Kramer
JAJeanpun Antarasen
Jeanpun Antarasen
CRCole R. Reinholt
Cole R. Reinholt
LKLydia Kisley
Lydia Kisley
We present a comprehensive guide to light-sheet microscopy (LSM) to assist scientists in navigating the practical implementation of this microscopy technique. Emphasizing the applicability of LSM to image both static microscale and nanoscale features, as well as diffusion dynamics, we present the fundamental concepts of microscopy, progressing through beam profile considerations, to image reconstruction. We outline key practical decisions in constructing a home-built system and provide insight into the alignment and calibration processes. We briefly discuss the conditions necessary for constructing a continuous 3D image and introduce our home-built code for data analysis. By providing this guide, we aim to alleviate the challenges associated with designing and constructing LSM systems and offer scientists new to LSM a valuable resource in navigating this complex field.

12 June 2026 in ACS Sensors
Verified
Journal Article
Open access
AMAnshuman Mohapatra
Anshuman Mohapatra
JAJeanpun Antarasen
Jeanpun Antarasen
DLDanielle R. Latham
Danielle R. Latham
MBMarisa A. Barilla
Marisa A. Barilla
CDCaitlin M. Davis
Caitlin M. Davis
LKLydia Kisley
Lydia Kisley
The cellular cytosol is a crowded environment. Biomolecular Förster resonance energy transfer (FRET) sensors have been developed to measure crowding in cytosol mimics composed of synthetic polymers such as polyethylene glycol (PEG) and Ficoll that impart an excluded volume effect. We investigate the PEG-driven phase separation of a protein crowding sensor, AcGFP1/mCherry-FRET crowding helix 2 (CrH2), into fluorescent puncta compared to a DNA-based crowding sensor (CrD) with an Alexa488/Cy5 FRET pair that did not form observable puncta under the same crowding conditions of 100-400 mg/mL 8 kDa PEG. Using fluorescence recovery after photobleaching imaging, we uncover the liquid-like physical properties of the PEG-induced puncta. Two-color fluorescence microscopy imaging reveals crowder-induced inhomogeneity, concentration variations, and partition coefficients across the dilute and dense phases of the liquid puncta, which remain largely underexplored in bulk fluorometry measurements. Thus, the average crowding sensor response may originate from an aqueous biphasic system, reporting an erroneous average response instead of distinct levels of crowdedness. A comparison of excluded volume effects conferred by Ficoll and PEGs of various molecular weights shows the influence of size, concentration, excluded volume, and chemical composition on the CrH2 sensor response. We demonstrate that ≥18% PEG (w/v) was sufficient to enable the phase separation of CrH2 and alter sensor response through a mechanism that may be driven by polymer interactions with the flexible hinge region. We also show that CrD can form fluorescence puncta upon charge-neutralization with poly-l-lysine. Thus, our study emphasizes the need to probe crowding environments with orthogonal sensors.