Rolf B. Saager

Rolf B. Saager

Auto-generated profile, based on publicly available information

Rolf B. Saager

Linköping University

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2005 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
RSRolf B. Saager
Rolf B. Saager
ABAndrew J. Berger
Andrew J. Berger
We propose a method to isolate absorption trends confined to the lower layer of a two-layer turbid medium, as is desired in near-infrared spectroscopy (NIRS) of cerebral hemodynamics. Several two-layer Monte Carlo simulations of NIRS time series were generated using a physiologically relevant range of optical properties and varying the absorption coefficients due to bottom-layer, top-layer, and/or global fluctuations. Initial results showed that by measuring absorption trends at two source–detector separations and performing a least-squares fit of one to the other, processed signals strongly resemble the simulated bottom-layer absorption properties. Through this approach, it was demonstrated that fitting coefficients can be estimated within less than ±2% of the ideal value without any a priori knowledge of the optical properties present in the model. An analytical approximation for the least-squares coefficient provides physical insight into the nature of errors and suggests ways to reduce them.

1 April 2011 in NeuroImage
Verified
Journal Article
Closed access
RSRolf B. Saager
Rolf B. Saager
NTNicole L. Telleri
Nicole L. Telleri
ABAndrew J. Berger
Andrew J. Berger

1 January 2008 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RSRolf Saager
Rolf Saager
ABAndrew Berger
Andrew Berger
A multidetector, continuous wave, near-infrared spectroscopy (NIRS) system is developed to examine whether the hemodynamics of the scalp and brain in adults contain significant layer-like hemodynamic trends. NIRS measurements are made using contrasting geometries, one with four detectors equidistant from a source 33mm away, and one with detectors collinear with the source (5 to 33mm away). When NIRS time series are acquired over the prefrontal cortex from resting adults using both geometries, variations among the time series are consistent with a substantially homogeneous two-layer model (p<0.001) and inconsistent with one dominated by heterogeneities. Additionally, when time series measured 5mm from the source are subtracted from corresponding 33-mm signals via a least-squares algorithm, 60% of the hemoglobin changes are on average removed. These results suggest that hemodynamic trends present in the scalp can contribute significantly to NIRS measurements, and that attempts to reduce this noise by subtracting a simultaneous near-channel measurement using a two-layer model are justified. Such subtractions are then performed on NIRS measurements from two stimulus protocols. For systemic stimulations (Valsalva maneuver), the subtraction cancels the hemodynamic response, as desired. For localized stimulation of the occipital lobe (viewing a flickering pattern), the subtraction isolated a stimulus-correlated hemodynamic feature from background noise.

1 February 2014 in Academic Radiology
Verified
Journal Article
Closed access
DRDaniel J. Rohrbach
Daniel J. Rohrbach
DMDaniel Muffoletto
Daniel Muffoletto
JHJonathan Huihui
Jonathan Huihui
RSRolf Saager
Rolf Saager
KKKenneth Keymel
Kenneth Keymel
USUlas Sunar
Ulas Sunar

12 May 2014 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FVFartash Vasefi
Fartash Vasefi
Nicholas MacKinnonNicholas MacKinnon
Nicholas MacKinnon
RSRolf B. Saager
Rolf B. Saager
ADAnthony J. Durkin
Anthony J. Durkin
RCRobert Chave
Robert Chave
DFDaniel L. Farkas
Daniel L. Farkas
Attempts to understand the changes in the structure and physiology of human skin abnormalities by non-invasive optical imaging are aided by spectroscopic methods that quantify, at the molecular level, variations in tissue oxygenation and melanin distribution. However, current commercial and research systems to map hemoglobin and melanin do not correlate well with pathology for pigmented lesions or darker skin. We developed a multimode dermoscope that combines polarization and hyperspectral imaging with an efficient analytical model to map the distribution of specific skin bio-molecules. This corrects for the melanin-hemoglobin misestimation common to other systems, without resorting to complex and computationally intensive tissue optical models. For this system's proof of concept, human skin measurements on melanocytic nevus, vitiligo, and venous occlusion conditions were performed in volunteers. The resulting molecular distribution maps matched physiological and anatomical expectations, confirming a technologic approach that can be applied to next generation dermoscopes and having biological plausibility that is likely to appeal to dermatologists.

1 June 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
RSRolf B. Saager
Rolf B. Saager
MBMihaela Balu
Mihaela Balu
VCViera Crosignani
Viera Crosignani
ASAta Sharif
Ata Sharif
ADAnthony J. Durkin
Anthony J. Durkin
BTBruce J. Tromberg
Bruce J. Tromberg
The combined use of nonlinear optical microscopy and broadband reflectance techniques to assess melanin concentration and distribution thickness in vivo over the full range of Fitzpatrick skin types is presented. Twelve patients were measured using multiphoton microscopy (MPM) and spatial frequency domain spectroscopy (SFDS) on both dorsal forearm and volar arm, which are generally sun-exposed and non-sun-exposed areas, respectively. Both MPM and SFDS measured melanin volume fractions between ∼5% (skin type I non-sun-exposed) and 20% (skin type VI sun exposed). MPM measured epidermal (anatomical) thickness values ∼30–65  μm, while SFDS measured melanin distribution thickness based on diffuse optical path length. There was a strong correlation between melanin concentration and melanin distribution (epidermal) thickness measurements obtained using the two techniques. While SFDS does not have the ability to match the spatial resolution of MPM, this study demonstrates that melanin content as quantified using SFDS is linearly correlated with epidermal melanin as measured using MPM (R2=0.8895). SFDS melanin distribution thickness is correlated to MPM values (R2=0.8131). These techniques can be used individually and/or in combination to advance our understanding and guide therapies for pigmentation-related conditions as well as light-based treatments across a full range of skin types.