15 December 2025 in Metal Working and Material Science
Introduction. There is a growing demand for eco-friendly cutting fluids in machining due to their non-toxicity, sustainability, high performance, and ability to improve surface quality. These fluids support green manufacturing practices and promote a safe working environment. Copper oxide-based nanofluids offer the combined benefits of enhanced heat transfer, increased safety, and reduced tool wear and cutting forces. The purpose of the work. This research focuses on evaluating the performance of copper oxide-based cutting fluids in turning processes to support sustainable and eco-conscious manufacturing. The study investigates the turning of SS 304 steel using varying concentrations of copper oxide nanofluids. The methods of investigation. In this study, the turning process was tested under various machining conditions using different concentrations of copper oxide nanoparticles (0.3 %, 0.6 %, 0.9 %, 1.2 %, and 1.5 %). Corn oil was selected as the base oil, and the copper oxide nanoparticles were dispersed in the corn oil to prepare the nanofluid. Machining trials were conducted under different lubrication environments: dry, wet, minimum quantity lubrication (MQL), and nano-enhanced MQL (nMQL). A comparative study was performed to assess cutting temperature and cutting forces. Results and discussion. The results showed that the use of 1.2 % copper oxide nanofluid led to significant reductions in cutting force and cutting temperature, by approximately 17.54 % and 29.53 %, respectively, compared to traditional dry and wet machining environments. Furthermore, the nanofluid was observed to form a protective film at the tool-workpiece interface, reducing tool wear. These findings highlight the potential of copper oxide-based green cutting fluids to improve turning operation efficiency and promote environmentally sustainable practices.
15 December 2025 in Metal Working and Material Science
Introduction. Photochemical machining (PCM) is a non-traditional machining method capable of developing burr-free and stress-free biomedical components. A stent is a small meshed tube used to remove blockages and open blood passages in arteries and veins. SS316L is one of the recommended materials for stents due to its biocompatibility and machinability with photochemical processes. Vascular stents are made from metal mesh, fabric, silicone, or combinations of materials. The purpose of this work is to investigate the effect of process parameters on the PCM process during the machining of SS316L and to manufacture an SS316L stent as a substrate using photochemical machining. The manufactured stent is used in larger arteries, such as the aorta, to provide a stable channel for blood flow. Methods of investigation. The process parameters for the photochemical machining process were optimized using the Taguchi method with an L9 experimental array (DoE). The effect of process parameters on responses was investigated using F-values. An ANN was employed as a predictive tool for observing deviations in the responses. Results and discussion. The optimum set of machining parameters was obtained and utilized for manufacturing the vascular stent. A phototool with the required stent strut size was developed using CAD software. Controlled etching with ferric chloride generated the mesh, and laser seam welding was performed to develop the tubular stent for placement in blockages. The dimensions of the developed stent were measured with SEM, and the stent strut size was found to vary from 312 µm to 900 µm.
15 September 2026 in Metal Working and Material Science
Introduction. Additive manufacturing, and in particular fused deposition modelling (FDM), enables the fabrication of geometrically complex parts without dedicated tooling, which is especially valuable for patient-specific biomedical devices. The mechanical performance of polylactic acid (PLA) parts, however, depends strongly on the combination of printing parameters, and the available data on the joint influence of layer thickness, nozzle temperature, and material flow rate on the full set of strength characteristics remain fragmentary, which complicates process selection for anatomical prototypes. The aim of this work is to determine the optimum combination of FDM printing parameters for PLA parts that maximizes the integrated strength response, and to fabricate, using the identified settings, a full-scale patient-specific prototype of the human talus bone from computed tomography data. Materials and methods. A Taguchi L27 orthogonal array was implemented with three levels of layer thickness (0.1–0.3 mm), nozzle temperature (190–210 °C), and material flow rate (95–105%). Tensile strength and Young's modulus were determined in accordance with ASTM D638–22 on a universal testing machine at a crosshead speed of 5 mm/min; specific fracture energy (toughness) was measured according to ASTM D256–23 using a notched Izod pendulum impact tester. The significance of the factors was evaluated by analysis of variance (ANOVA), and multi-response optimization was performed by grey relational analysis (GRA). The geometry of the fabricated prototype was inspected on a coordinate measuring machine. Results and discussion. Material flow rate was found to be the dominant factor for tensile strength (contribution of 50.3 %) and for toughness (92.9%), whereas Young's modulus is governed primarily by layer thickness. The highest grey relational grade (0.853) was obtained at a layer thickness of 0.1 mm, a nozzle temperature of 210 °C, and a flow rate of 105%. The dimensional deviations of the fabricated prototype from the CT data did not exceed 0.2 mm, which confirms its suitability as a master model for the subsequent manufacture of an implant from a biocompatible material.