1 January 2014 in Surface and Coatings Technology
9 March 2020 in Journal of Applied Electrochemistry
30 May 2018 in Journal of the Electrochemical Society
An analysis of the anodic reaction occurring at soluble copper anodes during the electrodeposition of copper from an ethaline-based deep eutectic solvent (DES) has been performed. It was shown by UV-Vis spectroscopy and electrochemical measurements that the dominant anodic species produced is the CuCl2− complex. In pure ethaline the current efficiency of the anodic process is 100% and the dissolution valency is one. However, in the presence of Cu(II) species the apparent dissolution valency measured gravimetrically was typically less than unity, corresponding to an observed mass loss greater than that expected from Faraday's law. Moreover, the apparent dissolution valency showed a marked dependence on the electrode rotation rate, Cu(II) concentration and the water content of the deep eutectic solvent. These observations were consistent with a corrosion reaction occurring in parallel with anodic dissolution. The most likely corrosion process is the comproportionation reaction: CuCl42− + Cu → 2CuCl2−. Voltammetric data indicate that the rate of this process is controlled by the mass transport of the CuCl42− complex to the surface and can readily explain the observed dissolution valency dependencies. Finally, it is noted that complex dissolution of Cu anodes in deep eutectic solvents makes their implementation as soluble anodes problematic.
1 July 2014 in Chemical Engineering Science
This work reports an investigation on mass transfer by ultrasound agitation during electrodeposition on electrodes separated by a narrow inter-electrode gap. Polarisation experiments were performed to identify the mass transfer limiting current. The limiting current density was used to calculate mass transfer boundary layer thicknesses which were used to develop mass transfer correlations. Experiments were carried out using a cell with parallel copper discs which were positioned at gaps of 1, 0.5 and 0.15cm. The distance between the ultrasonic probe and electrodes was varied between 3 and 1.5cm. The polarisation data showed clear limiting current plateaux when the distance between the electrodes was larger, however significant distortions were observed when the gap was 0.15cm. It was found that lower ultrasound powers of 9–18W/cm2 provided more effective agitation at narrower electrode gaps than powers exceeding 18W/cm2. Sherwood correlations showed that in this system, developing turbulence occurs for larger inter-electrode spacing, whereas for narrow electrode gaps fully turbulent correlations were obtained. A 2-D current distribution model showed that potential distortions that were observed in the polarisation data were caused by the close placement of the metallic US probe to the two parallel electrodes
1 November 2016 in Journal of Physics and Chemistry of Solids
1 September 2016 in Hydrometallurgy