Roberto Foroni

Roberto Foroni

Auto-generated profile, based on publicly available information

Roberto Foroni

Department of Radiology (F.B.P., R.I.F.), Department of Diagnostic and Public Health, Verona University, Verona, Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
ARA. Rojas-Villabona
A. Rojas-Villabona
FPFrancesca Benedetta Pizzini
Francesca Benedetta Pizzini
TST. Solbach
T. Solbach
MSM. Sokolska
M. Sokolska
GRGiuseppe Kenneth Ricciardi
Giuseppe Kenneth Ricciardi
HJH.R. Jäger
H.R. Jäger
BACKGROUND AND PURPOSE: Intra-arterial DSA has been traditionally used for confirmation of cure following gamma knife radiosurgery for AVMs. Our aim was to evaluate whether 4D arterial spin-labeling MRA and contrast-enhanced time-resolved MRA in combination can be an alternative to DSA for confirmation of AVM obliteration following gamma knife radiosurgery. MATERIALS AND METHODS: In this prospective study, 30 patients undergoing DSA for confirmation of obliteration following gamma knife radiosurgery for AVMs (criterion standard) also underwent MRA, including arterial spin-labeling MRA and contrast-enhanced time-resolved MRA. One dataset was technically unsatisfactory, and the case was excluded. The DSA and MRA datasets of 29 patients were independently and blindly evaluated by 2 observers regarding the presence/absence of residual AVMs. RESULTS: The mean time between gamma knife radiosurgery and follow-up DSA/MRA was 53 months (95% CI, 42–64 months; range, 22–168 months). MRA total scanning time was 9 minutes and 17 seconds. Residual AVMs were detected on DSA in 9 subjects (obliteration rate = 69%). All residual AVMs were detected on at least 1 MRA sequence. Arterial spin-labeling MRA and contrast-enhanced time-resolved MRA showed excellent specificity and positive predictive values individually (100%). However, their sensitivity and negative predictive values were suboptimal due to 1 false-negative with arterial spin-labeling MRA and 2 with contrast-enhanced time-resolved MRA (sensitivity = 88% and 77%, negative predictive values = 95% and 90%, respectively). Both sensitivity and negative predictive values increased to 100% if a composite assessment of both MRA sequences was performed. Diagnostic accuracy (receiver operating characteristic) and agreement (κ) are maximized using arterial spin-labeling MRA and contrast-enhanced time-resolved MRA in combination (area under receiver operating characteristic curve = 1, P < .001; κ = 1, P < .001, respectively). CONCLUSIONS: Combining arterial spin-labeling MRA with contrast-enhanced time-resolved MRA holds promise as an alternative to DSA for confirmation of obliteration following gamma knife radiosurgery for brain AVMs, having provided 100% sensitivity and specificity in the study. Their combined use also enables reliable characterization of residual lesions.

1 December 2010 in Journal of Neurosurgery
Verified
Journal Article
Closed access
PDF file
MGMassimo Gerosa
Massimo Gerosa
NMNazarena Mesiano
Nazarena Mesiano
Michele LonghiMichele Longhi
Michele Longhi
ASAntonio De Simone
Antonio De Simone
RFRoberto Foroni
Roberto Foroni
Antonio NicolatoAntonio Nicolato
Antonio Nicolato
During the past decades, in small-to-medium size vestibular schwannomas, Gamma Knife surgery (GKS) has become a reliable therapeutic option because of either excellent local tumor control or minimal morbidity, with cranial neuropathy becoming increasingly rare. Although still insufficiently analyzed in larger cohorts of patients with long-term follow-ups, adequate chances of hearing preservation and vestibular sparing seem clinically guaranteed. However, deeper investigations are needed in this regard, expanding the number of cases and the follow-up period. A small group of patients with vestibular schwannomas (74 patients, including 41 men and 33 women) treated between 2003 and 2009 using GKS at the authors' institution were analyzed—both before and after GKS—with computerized static stabilometry and electronystagmography for balance disorders, vertigo, and ataxia on 1 side and pure tone average, vocal speech discrimination score, auditory brainstem response, and so forth for hearing impairment and tinnitus on the other side. Eligibility criteria for this prospective study included previously untreated unilateral lesions and a Gardner-Robertson hearing class of I–III. Dosimetry plans had been programmed at the lower effective dosages for these tumors (median surface dose 12.4 Gy, range 10–13 Gy), carefully avoiding even minimal toxic dosages on the most vulnerable targets: the cochlea (never > 6 Gy) and the vestibular canals (< 7.5 Gy). To date, tumor growth control rates remain satisfactory; at a mean follow-up of 50 months, the rate was 96%. The overall level of hearing preservation was 72%, with 81% having Gardner-Robertson Class I hearing. Tinnitus decreased, from 52% to 28% of patients (p < 0.01). Significant improvements were also observed in vestibular symptoms, with computerized static stabilometry abnormalities decreasing from 62% to 32% (p < 0.001) and electronystagmography abnormalities reducing from 48% to 14% (p < 0.001). Using appropriate radiodosimetry planning, GKS seems to guarantee not only adequate tumor growth control rates, but also better levels of hearing preservation, with a documented, long-lasting improvement in vestibular functions.

4 March 2010
Verified
Conference Paper
Closed access
PDF file
RSReuben R. Shamir
Reuben R. Shamir
LJLeo Joskowicz
Leo Joskowicz
LALuca Antiga
Luca Antiga
RFRoberto I. Foroni
Roberto I. Foroni
YSYigal Shoshan
Yigal Shoshan
We present a new preoperative planning method to quantify and help reduce the risk associated with needle and tool insertion trajectories in image-guided keyhole neurosurgery. The goal is to quantify the risk of a proposed straight trajectory, and/or to find the trajectory with the lowest risk to nearby brain structures based on pre-operative CT/MRI images. The method automatically computes the risk associated with a given trajectory, or finds the trajectory with the lowest risk to nearby brain structures based on preoperative image segmentation and on a risk volume map. The surgeon can revise the suggested trajectory, add a new one using interactive 3D visualization, and obtain a quantitative risk measure. The trajectory risk is evaluated based on the tool placement uncertainty, on the proximity of critical brain structures, and on a predefined table of quantitative geometric risk measures. Our preliminary results on a clinical dataset with eight targets show a significant reduction in trajectory risk and a shortening of the preoperative planning time as compared to the conventional method.

1 November 2010
Verified
Conference Paper
Closed access
FFFrancesca Pizzorni Ferrarese
Francesca Pizzorni Ferrarese
FSFlavio Simonetti
Flavio Simonetti
RFRoberto Foroni
Roberto Foroni
GMGloria Menegaz
Gloria Menegaz
Validation and accuracy assessment are the main bottlenecks preventing the adoption of many medical image processing algorithms in the clinical practice. In the classical approach, a-posteriori analysis is performed based on some predefined objective metrics. In this paper, a different approach based on Petri Nets is proposed. The basic idea consists in predicting the accuracy that will result from a given processing on a given type of data based on the identification and characterization of the sources of inaccuracy intervening along the whole chain. Here it is proposed a proof of concept in the specific case of noisy Magnetic Resonance image registration. Magnetic Resonance images are normally corrupted by random noise from the measurement process complicating the automatic feature extraction and analysis of clinical data. The accurate registration of images observed in additive noise is a challenging task. The noise can increase the number of misregistered regions, and decrease the accuracy of subpixel registration. A Petri Net is built after the detection of the possible sources of inaccuracy, ranging from the images noise to the registration parameters adopted, and the evaluation of their respective impact on the estimation of the deformation field. A training set of five different synthetic volumes is used. Afterward, validation is performed on a different set of five synthetic volumes by comparing the estimated inaccuracy with the posterior measurements according to a set of predefined metrics. Results show that the proposed model provides a good prediction performance. An extended set of clinical data will allow the complete characterization of the system for the considered task.

1 May 1994 in Rivista di Neuroradiologia
Verified
Journal Article
Closed access
EPE. Piovan
E. Piovan
PZP.G. Zampieri
P.G. Zampieri
MGM.A. Gerosa
M.A. Gerosa
APA. Pasqualin
A. Pasqualin
Antonio NicolatoAntonio Nicolato
Antonio Nicolato
ABA. Benati
A. Benati