In this article, the electromagnetic force and vibration characteristics of 10-pole 12-slot and 14-pole 12-slot permanent magnet synchronous motors (PMSMs) are examined considering the tooth modulation effect. In contrast to the conventional electromagnetic force analysis process which considers only the radial force of the lowest spatial harmonic order, the radial and tangential forces include low and high spatial harmonic orders which can be modulated with a lower spatial harmonic order, are analyzed. Then, a structural finite-element (FE) model is developed, and vibration analysis is performed by applying a modulated force and moment. In the analysis, the amplitude and phase of the modulated radial force, tangential force, and moment are considered. The vibration analysis result shows that the 10-pole 12-slot PMSM is disadvantageous with respect to vibration when compared to the 14-pole 12-slot PMSM owing to the large modulated force. Also, it is confirmed that the effect of modulated tangential force and moment cannot be neglected, and the phase difference between modulated radial, tangential force and moment is also an important factor in vibration. Finally, the two motors are fabricated, and the validity of the FE analysis results is verified using the test results.
8 April 2021 in IEEE Transactions on Vehicular Technology
The accuracy of motor characteristics prediction according to driving cycle can be improved by taking temperature change of motor into account. From this point of view, this paper proposes a fast and accurate coupled analysis method. To calculate motor circuit parameters, electromagnetic finite element analysis (FEA) is used. The proposed method consists of two stages to exclude the time consuming FEA from repetitive process. In pre-process stage, the circuit parameters are stored as look-up tables (LUTs) considering motor temperature. Further, a technique that allows reducing the number of analyses is developed to consider a wide operating temperature range with less time consumption. In main process stage, the torque and voltage equations are solved using the circuit parameter LUTs. Among the solved motor characteristics, losses are applied to lumped parameter thermal network (LPTN) as heat sources to figure out thermal characteristics. Here, techniques including loss separation and thermal parameter tuning are introduced to improve both accuracy and speed of the LPTN. Since the computation of the characteristic equations and LPTN are fast, the iterative analysis at entire time steps of the driving cycle is facilitated. An example of the proposed method is presented using worldwide harmonized light vehicle test procedure (WLTP). Thereafter, the effectiveness of the method is discussed by comparison with conventional methods. Finally, the experimental verifications are conducted to validate the electromagnetic FEA and LPTN used in this study.
9 January 2023 in IEEE Transactions on Industrial Electronics
As the torque density of traction motors for electric vehicles (EVs) increases, winding technology with a large conductor area, such as hairpin winding, is widely used. However, it has a disadvantage of large AC copper loss affected by the skin and proximity effect. Therefore, the AC copper loss should be considered for deriving characteristics of interior permanent magnet synchronous motors (IPMSMs). This article deals with the maximum torque per ampere (MTPA) and flux-weakening control characteristics of the IPMSM considering AC copper loss. As the AC copper loss is caused by armature and field excitation, a separation process of AC copper loss by each cause is proposed. By using the process, the separated AC copper loss can be analyzed according to the current vector and rotational speed. However, it is inefficient to calculate the AC copper loss according to rotational speed using transient analysis. Therefore, a computationally efficient method of calculating AC copper loss based on magneto-static analysis is presented. In addition, advanced d, q -axis equivalent model considering AC copper loss is proposed to analyze MTPA and flux-weakening control characteristics of IPMSM. By using the proposed d, q -axis equivalent model, the IPMSM can be designed considering the AC copper loss efficiently and accurately.
7 June 2021 in IEEE Transactions on Industry Applications
This article proposes a fast and accurate coupled electromagnetic-thermal analysis method for a permanent magnet synchronous motor. In conventional design methods, the electric and thermal characteristics are calculated simultaneously using a finite element analysis (FEA). However, FEA requires considerable computational time. Therefore, in order to reduce the computational time, mathematical models of the electric parameters and characteristics were proposed as an alternative. Accordingly, the models of the electric parameter, such as d- and q-axis inductance and flux linkage, were obtained using a modified lumped parameter magnetic circuit containing a reluctance of an iron core. Furthermore, the models were fitted according to the formula type to consider nonlinearity according to variations in current and temperature. The electric parameters calculated by FEA were used for curve fitting. A greater number of FEA points were required to determine the effect of current and temperature on the electric parameters. Curve fitting using an appropriate formula type was performed considering the accuracy and minimum number of analysis points. Mathematical modeling of the electric characteristics, including efficiency and losses, was performed. The models of losses were coupled as heat sources to the lumped parameter thermal network, which is well known for its low computational time. The proposed coupled analysis method was applied to a reference motor; through this analysis, the electric characteristics and temperature distribution were calculated simultaneously, considering changes in losses and temperature distribution. The experimental validation was conducted with an acceptable error of 4.4%.
23 October 2023 in IEEE Transactions on Industry Applications
In this study, the radial vibration of fractional-slot concentrated winding (FSCW) permanent magnet synchronous motor (PMSM) was analyzed according to pole/slot combination considering phase relationship of modulated radial, tangential forces, and moment. First, to calculate the modulated forces and moment according to pole/slot combination, the amplitude and phase of modulated radial, tangential force and moment converted by radial air-gap electromagnetic force density (AEFD) are analytically derived. Since the lever arm effect by tangential force varies according to the tooth length, tangential force was translated on the yoke and an equivalent modulated moment was derived. Subsequently, to analyze the radial vibration caused by modulated forces and moment, the radial displacement response owing to a unit radial AEFD is calculated using 3D structural finite element analysis by applying unit modulated forces and moment. It was found out that the tooth modulation effect hardly varied with pole/slot combination and shape of the PMSM such as tooth length. Rather, it was confirmed that the tooth modulation effect was significantly influenced by the slot opening width. Especially, it was analyzed that the radial vibration of PMSM is not simply reduced by optimizing the slot opening width with reduced modulated radial force, but the amplitude and phase of the modulated tangential force and moment should also be considered. Finally, four prototypes of the PMSM with different slot opening widths of two 12-slot 10-pole and two 12-slot 14-pole are fabricated, and the test and simulation results are compared and verified.
16 November 2021 in IEEE/ASME Transactions on Mechatronics
In this article, the nonlinear parameters of a throttle valve were analyzed and calculated to predict its dynamic characteristics. A mathematical model considering nonlinear parameters is employed to improve the control performance over the throttle valve. Electrical nonlinearity is caused by the brush and commutator. A brush contact resistance is generated due to the contact between the brush and commutator. The brush contact resistance is affected by the rotor speed and the input current. Furthermore, mechanical nonlinearity is caused by the limp-home mode in the spring. The torque produced by the spring varies with the valve angle. As it is difficult to estimate nonlinear parameters accurately, electrical and mechanical parameters were calculated experimentally. In addition, a block diagram considering the nonlinearity of the electrical and mechanical parameters was developed. Finally, the test and simulation results were compared to validate the estimated nonlinear parameters.