Viviane Bortoluzzi Frasson

Viviane Bortoluzzi Frasson

Auto-generated profile, based on publicly available information

Viviane Bortoluzzi Frasson

Physique Centro de Fisioterapia, Porto Alegre, RS, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Physical Therapy
Verified
Journal Article
Closed access
PDF file
IPIsabel de Almeida Paz
Isabel de Almeida Paz
GRGraciane Taglian Rigo
Graciane Taglian Rigo
ASAmanda Sgarioni
Amanda Sgarioni
BBBruno Manfredini Baroni
Bruno Manfredini Baroni
VFViviane Bortoluzzi Frasson
Viviane Bortoluzzi Frasson
MVMarco Aurélio Vaz
Marco Aurélio Vaz
Objective: Tolerance level and rapid fatigue onset are limitations in the use of neuromuscular electrical stimulation (NMES) as an electrotherapeutic resource in rehabilitation and training protocols; however, it is unclear if pulsed current (PC) and alternating current (AC) produce different fatigue levels when applied at submaximal contraction level. The purpose of this study was to compare fatigue and discomfort levels between PC and AC during a submaximal contraction protocol in people who are healthy.Methods: In this double-blind, randomized crossover trial conducted in a laboratory setting, 30 male volunteers [23.23 years of age (SD = 4.59)] performed 2 submaximal fatigue protocols (with a 7-day interval) in a randomized order: PC (pulse duration = 2 milliseconds, pulse frequency = 100 Hz) and AC (2.5 kHz, pulse duration = 0.4 milliseconds, burst frequency = 100 Hz). NMES currents were applied to the knee extensor motor point of the dominant limb. The NMES protocol consisted of 80 evoked contractions (time on:off = 5:10 seconds) and lasted 20 minutes. The current was maintained at a constant intensity throughout the NMES protocol. The primary outcome measures were maximal voluntary isometric contraction, fatigue index (evoked torque decline), fatigability (number of contractions for a 50% drop in evoked-torque from the protocol start), total evoked torque-time integral (TTI), decline in TTI, and discomfort level.Results: AC at 2.5 kHz demonstrated higher maximal voluntary isometric contraction decline post-fatigue, higher fatigue index, higher fatigability (ie, fewer contractions to reach the 50% evoked torque decline from the protocol start), smaller total TTI, and higher TTI decline compared with PC. No between-currents difference was observed in discomfort level.Conclusion: PC is less fatigable than AC at 2.5 kHz.Impact: Based on this study, PC is the preferred current choice when the NMES goal is to generate higher muscle work, higher mechanical load, and smaller fatigability during training both for athletes who are healthy and for rehabilitation programs for people with disease or injury.

2 June 2022 in Brazilian Journal of Physical Therapy
Verified
Journal Article
Closed access
GGGabriela Bissani Gasparin
Gabriela Bissani Gasparin
VFViviane Bortoluzzi Frasson
Viviane Bortoluzzi Frasson
CFCarolina Gassen Fritsch
Carolina Gassen Fritsch
AMAnete Morales
Anete Morales
MVMarco Aurélio Vaz
Marco Aurélio Vaz
BBBruno Baroni
Bruno Baroni

17 June 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
VFViviane Bortoluzzi Frasson
Viviane Bortoluzzi Frasson
Walter HerzogWalter Herzog
Walter Herzog
KJKelly Johnston
Kelly Johnston
YPYves Pauchard
Yves Pauchard
MVMarco Aurélio Vaz
Marco Aurélio Vaz
BBBruno Manfredini Baroni
Bruno Manfredini Baroni

1 August 2023 in Journal of Sport Rehabilitation
Verified
Journal Article
Closed access
PDF file
LOLetícia Almeida de Oliveira
Letícia Almeida de Oliveira
VFViviane Bortoluzzi Frasson
Viviane Bortoluzzi Frasson
ATAnna Torresan
Anna Torresan
MVMarco Aurélio Vaz
Marco Aurélio Vaz
BBBruno Baroni
Bruno Baroni
Context: Laboratorial 3-dimensional kinematic analyses have shown changes in the single-leg squat’s (SLS) pattern of patients with femoroacetabular impingement syndrome (FAIS). However, it is unknown whether clinicians are able to detect these changes using 2-dimensional kinematics. Objective: To compare the frontal plane 2-dimensional kinematics of patients with FAIS and asymptomatic individuals in the SLS test performed in a clinical setting. Design: Case-control study. Setting: Physical therapy clinic. Participants: Twenty men with bilateral FAIS and 20 asymptomatic men. Main Outcome Measures: Two-dimensional kinematic analysis was collected in the frontal plane during the execution of the SLS test. The outcomes were squat depth, pelvic drop (pelvis angle relative to the horizontal plane), hip adduction (femur angle relative to the pelvis), and knee valgus (femur angle relative to the tibia). Results: Most and least painful limbs of patients with FAIS had squat depth (9.8% [2.9%] and 9.5% [3.1%] of height), pelvic drop (4.2° [3.9°] and 3.7° [4.2°]), hip adduction (74.9° [5.8°] and 75.9° [5.7°]), and knee valgus (4.0° [11.0°] and 5.0° [9.9°]) similar to asymptomatic individuals (9.0% [2.3%], 4.8° [2.6°], 73.7° [4.9°], and −1.7° [8.5°]; P > .05 for all). Conclusion: The frontal plane 2-dimensional kinematic analysis of the SLS test in the clinical setting is not able to distinguish patients with FAIS from asymptomatic individuals.

1 November 2024 in Journal of Sport Rehabilitation
Verified
Journal Article
Closed access
PDF file
KPKlauber D. Pompeo
Klauber D. Pompeo
RRRodrigo Rabello
Rodrigo Rabello
AMAnete B. Morales
Anete B. Morales
KKKelli D. Klein
Kelli D. Klein
VFViviane B. Frasson
Viviane B. Frasson
MVMarco Aurélio Vaz
Marco Aurélio Vaz
Context: The evaluation of quadriceps muscle inhibition with the interpolated twitch technique is usually performed by stimulating the femoral nerve (FN). However, there are some problems related to the use of this stimulation site, which may be partially overcome by delivering the stimulation over the motor point (MP). This study sought to compare MP to FN stimulation at different joint angles for the evaluation of quadriceps muscle inhibition, resting peak torque, and discomfort in healthy women. Design: Cross-sectional study. Methods: Sixteen healthy women (age: 28 [4] y; body mass: 60 [5] kg; height: 162 [5] cm) participated in this study. Supramaximal paired stimuli were delivered to the FN and to the rectus femoris MP before and during maximal voluntary contractions at different knee angles (15°, 30°, 45°, 60°, and 90° of knee flexion) to assess muscle inhibition and resting peak torque. Discomfort was also recorded for each stimulation site and knee angle. Results: Muscle inhibition was similar between the 2 stimulation sites (P > .05) and was higher at 45° than at 90° (P = .03). MP stimulation evoked lower resting peak torque at 30° (P = .004), 60° (P = .006), and 90° (P = .006) and higher discomfort at 30° (P = .008) and 90° (P = .027) compared to FN stimulation. Conclusions: Despite lower resting peak torque and higher discomfort at some angles, MP stimulation provided similar muscle inhibition to FN stimulation at all knee angles and is therefore a valid method to evaluate quadriceps muscle inhibition in healthy women. MP stimulation can be used as an alternative to FN stimulation for the evaluation of quadriceps muscle inhibition with no added discomfort at the angles where muscle inhibition is the highest.

23 March 2024 in Brazilian Journal of Physical Therapy
Verified
Journal Article
Closed access
VFViviane Bortoluzzi Frasson
Viviane Bortoluzzi Frasson
MVMarco Aurélio Vaz
Marco Aurélio Vaz
MTMarco Aurélio Telöken
Marco Aurélio Telöken
PGPaulo David Fortis Gusmão
Paulo David Fortis Gusmão
MCMarcus Vinicius Crestani
Marcus Vinicius Crestani
BBBruno Baroni
Bruno Baroni