21 March 2016 in European Journal of Dental Education
27 March 2019 in PLOS ONE
This study aimed to determine dental students’ visual acuity and neck angulation when using magnification devices and distances from the operating field. Forty students from each of the second through fifth years of the five-year program at the School of Dentistry of Araraquara were selected (N = 160). Visual acuity was tested using a miniature Snellen eye chart under five different settings (naked eye; simple loupe; Galilean loupe; Keplerian loupe and an operating microscope). Photographs were taken during the visual acuity exam in order to evaluate the angulation of the subjects’ necks in a neutral posture. The two-factor analysis of variance and the Games-Howell post-hoc test were performed (α = 0.05). A significant difference in visual acuity and neck angulation was found between the "magnification device" and "distance" factors in each of the graduating classes analyzed (p<0.05). At a standardized distance, the Keplerian loupe (535.93±133.69), the Galilean loupe (514.06±171.56), and the operating microscope (517.71±161.61) all provided greater visual acuity. At a subjectively comfortable distance, the Keplerian (521.35±157.99) and Galilean (515.00±156.32) loupes produced the best visual acuity. The angulation of the neck was greater when the simple loupes (56,59±10,88) and naked eye (56.51±13.55) were used at a subjectively comfortable distance. At both a standardized distance and a comfortable distance, the Galilean and Keplerian magnification systems provided the best visual acuity and the lowest angulation of the operator’s neck. At a standardized distance of 30 cm to 40 cm, the operating microscopes produced similar results.
25 September 2020 in European Journal of Dental Education
20 February 2020 in European Journal of Dental Education
13 February 2018 in European Journal of Dental Education
1 October 2018 in European Journal of Dentistry
Objective: The main objective of this study is to assess the effect of the adhesive mode and chlorhexidine (CHX) on the microtensile strength of a universal bonding agent to sound and caries-affected dentins. Materials and Methods: Six intact third molars and six decayed third molars were sectioned to obtain two middle dentin specimens per tooth. Prime and Bond Elect Universal (Dentsply) was applied to specimens in two different modes: Etch-and-rinse (ER, phosphoric acid for 15s) and self-etch (SE, no phosphoric acid). 2% CHX (Cavity Cleanser, Bisco) was applied to both dentins for 30 s. Specimens were randomly assigned into eight groups (n = 3) according to the treatments applied to sound and caries-affected dentins: SE; ER; SE + CHX; and ER + CHX. All specimens were restored with TPH Spectra High Viscosity (Dentsply) composite resin and sectioned to obtain specimens of 0.8 ± 0.1 mm2. The microtensile bond strength test was conducted at 1 mm/min. The data were statistically analyzed by ANOVA and multiple comparisons' test (α = 0.05). Results: There was no significant difference between sound dentin and caries-affected dentin (P = 0.132). The highest bond strength was obtained with the application of the ER (31.81MPa). SE + CHX promoted the lowest bond strength with no statistical difference to ER + CHX (P > 0.05). Conclusions: ER mode for the universal bonding agent yielded the highest bond strength to sound and caries-affected dentins. CHX reduced the bond strength to both dentins regardless the application of phosphoric acid. Clinical Significance: The universal bonding agent increased the bond strength to sound and caries-affected dentins when applied by the ER mode.