Joyce Figueiredo de Lima Marques

Prof. Joyce Figueiredo de Lima Marques

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Dental Materials
Verified
Journal Article
Closed access
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
MMMaria Do Carmo Aguiar Jordão Mainardi
Maria Do Carmo Aguiar Jordão Mainardi
RPRegina Maria Puppin-Rontani
Regina Maria Puppin-Rontani
URUbirajara Pereira Rodrigues-Filho
Ubirajara Pereira Rodrigues-Filho
PLPriscila Christiane Suzy Liporoni
Priscila Christiane Suzy Liporoni
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar

4 August 2022 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
BSBruna Scarcello Strini
Bruna Scarcello Strini
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
RPRenata Pereira
Renata Pereira
DSDanielle Ferreira Sobral-Souza
Danielle Ferreira Sobral-Souza
VPVanessa Gallego Arias Pecorari
Vanessa Gallego Arias Pecorari
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
Purpose: Bulk-fill composite resins were developed to reduce time and facilitate the restorative procedure. However, considering their recent introduction on the market and the new formulations, their performance still requires evaluation. This study aimed to evaluate Knoop microhardness (KHN), diametral tensile strength (DTS) and degree of conversion (DC) of three Bulk-Fill composite resins and a conventional one. Materials and Methods: Sixty samples (n = 15; 8 mm ø x 4 mm height) were confectioned using a mold. Filtek Bulk-Fill (FBF), Tetric N-Ceram Bulk-Fill (TNC) and SonicFill 2 (SF2) were placed in 4 mm increments, and Filtek Z350 (FZ350) was placed in 2 mm increments. The KHN of top and bottom surfaces were tested using Knoop Hardness tester at 10 gf/10s. The DTS was tested under compressive load at 1.0 mm/min. The DC was measured by Fourier Transform Infrared (FTIR) spectroscopy. Differences in DTS and DC were analyzed by ANOVA and Tukey post hoc test. For KHN, Kruskal–Wallis and Wilcoxon tests were performed at α = 0.05. Results: Top surfaces of all composite resins had higher KHN than bottom surfaces. At top and bottom surfaces, FZ350 showed higher KHN than TNC and SF2. The highest DTS was obtained by FBF, followed by FZ350 and SF2. The highest DC was obtained by SF2, the lowest one was obtained by FBF. Conclusion: From Bulk-Fill composite resins, FBF presented the best KHN and DTS results. The SF2 showed the best DC. Further studies are required to ensure whether these differences can negatively influence the behavior of in vivo restorations.

1 October 2018 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
DWDanielle Wajngarten
Danielle Wajngarten
FIFariya Islam
Fariya Islam
JCJohanna Clifford
Johanna Clifford
ABAna Carolina Botta
Ana Carolina Botta
Objective: The main objective of this study is to assess the effect of the adhesive mode and chlorhexidine (CHX) on the microtensile strength of a universal bonding agent to sound and caries-affected dentins. Materials and Methods: Six intact third molars and six decayed third molars were sectioned to obtain two middle dentin specimens per tooth. Prime and Bond Elect Universal (Dentsply) was applied to specimens in two different modes: Etch-and-rinse (ER, phosphoric acid for 15s) and self-etch (SE, no phosphoric acid). 2% CHX (Cavity Cleanser, Bisco) was applied to both dentins for 30 s. Specimens were randomly assigned into eight groups (n = 3) according to the treatments applied to sound and caries-affected dentins: SE; ER; SE + CHX; and ER + CHX. All specimens were restored with TPH Spectra High Viscosity (Dentsply) composite resin and sectioned to obtain specimens of 0.8 ± 0.1 mm2. The microtensile bond strength test was conducted at 1 mm/min. The data were statistically analyzed by ANOVA and multiple comparisons' test (α = 0.05). Results: There was no significant difference between sound dentin and caries-affected dentin (P = 0.132). The highest bond strength was obtained with the application of the ER (31.81MPa). SE + CHX promoted the lowest bond strength with no statistical difference to ER + CHX (P > 0.05). Conclusions: ER mode for the universal bonding agent yielded the highest bond strength to sound and caries-affected dentins. CHX reduced the bond strength to both dentins regardless the application of phosphoric acid. Clinical Significance: The universal bonding agent increased the bond strength to sound and caries-affected dentins when applied by the ER mode.

20 September 2018 in Microscopy Research and Technique
Verified
Journal Article
Closed access
PDF file
RSRodolfo X. de Sousa‐Lima
Rodolfo X. de Sousa‐Lima
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
LALucas José De Azevedo-Silva
Lucas José De Azevedo-Silva
LCLetícia V. de Freitas Chaves
Letícia V. de Freitas Chaves
RARoberta C. B. Alonso
Roberta C. B. Alonso
BBBoniek Castillo Dutra Borges
Boniek Castillo Dutra Borges

19 March 2025 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
MAMilagros Falcon Aguilar
Milagros Falcon Aguilar
WJWaldemir Francisco Vieira Junior
Waldemir Francisco Vieira Junior
VPVanessa Gallego Arias Pecorari
Vanessa Gallego Arias Pecorari
KRKlaus Rischka
Klaus Rischka
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar

1 January 2023 in RGO - Revista Gaúcha de Odontologia
Verified
Journal Article
Open access
PDF file
JMJoyce Figueiredo de Lima Marques
Joyce Figueiredo de Lima Marques
DSDanielle Ferreira Sobral-Souza
Danielle Ferreira Sobral-Souza
GMGiselle Maria Marchi
Giselle Maria Marchi
DLDébora Alves Nunes Leite Lima
Débora Alves Nunes Leite Lima
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
The CAD/CAM technology arose from the need to develop materials with better mechanical and optical properties that could be used for making monolithic restorations. Several materials have been used for milling indirect restorations in prefabricated blocks. Among them, lithium silicate reinforced with zirconia. Due to its recent introduction in the market, this case report aimed to present a detailed clinical protocol for the execution of a ceramic onlay of this material using CAD/CAM technology. A 57-year-old female patient sought care with extensive restoration in composite resin (BOMD) of tooth 15 maintained for almost two years. However, due to bruxism, constant dental tightening, the extension of the direct restoration and the need for improved esthetics, it was proposed to replace it with an indirect ceramic onlay restoration. Prophylaxis and choice of the color of the patient’s dental substrate were performed. Afterwards, the dental preparation was made and polished. Subsequently, the molding was made with addition silicone and the provisional restoration confectioned. Once the stone model was obtained, it was scanned and the ceramic onlay restoration was milled using CAD/CAM technology. Finally, the restoration was stained and cemented over the preparation. After 2 years, the restoration remained stable, with no evidence of color mismatch, marginal discoloration, marginal cleft, caries or fracture, proving the effectiveness of the treatment in this time interval. The correct indication of the ceramic material combined with the use of CAD/CAM technology facilitated the restorative process, restoring function and the esthetics desired by the patient.