1 November 2019 in Science Advances
Most vulnerable components identified by resistance centralities in electric power grids.
3 October 2019 in IEEE Access
The increasing penetration of new renewable sources of electrical energy reduces the overall mechanical inertia available in power grids. This raises a number of issues regarding grid stability over short to medium time scales. A number of approaches have been proposed to compensate for this inertia reduction by deploying substitution inertia in the form of synchronous condensers, flywheels or powerelectronic-based synthetic inertia. These resources are limited and expensive; therefore, a key issue is to determine how to optimally place them in the power grid, for instance, to mitigate voltage angle and frequency disturbances following an abrupt power loss. Performance measures in the form of H2—norms have recently been introduced to evaluate the overall magnitude of such disturbances. However, despite the mathematical convenience of these measures, analytical results can only be obtained under rather unrealistic assumptions of a uniform damping-to-inertia ratio or a homogeneous distribution of the inertia and/or primary control. Here, we introduce and apply matrix perturbation theory to obtain analytical results for an optimal inertia and primary control placement in the case where both are heterogeneous. This powerful method allows us to construct two simple algorithms that independently optimize the geographical distribution of the inertia and primary control. The algorithms are then implemented for a numerical model of the synchronous transmission grid of continental Europe with different initial configurations. We find that an inertia redistribution has little effect on the grid performance but that the primary control should be redistributed on the slow modes of the network, where the intrinsic grid dynamic requires more time to damp frequency disturbances. For a budget-constraint optimization, we show that increasing the amount of primary control in the periphery of the grid, without changing the inertia distribution, achieves 90% or more of the maximal possible optimization, already for relatively moderate budgets.
22 September 2023 in IEEE Transactions on Energy Markets, Policy and Regulation
This paper addresses the challenge of efficiently recovering exact solutions to the optimal power flow problem in real-time electricity markets. The proposed solution, named Physics-Informed Market-Aware Active Set learning OPF (PIMA-AS-OPF), leverages physical constraints and market properties to ensure physical and economic feasibility of market-clearing outcomes. Specifically, PIMA-AS-OPF employs the active set learning technique and expands its capabilities to account for curtailment in load or renewable power generation, which is a common challenge in real-world power systems. The core of PIMA-AS-OPF is a fully-connected neural network that takes the net load and the system topology as input. The outputs of this neural network include active constraints such as saturated generators and transmission lines, as well as non-zero load shedding and wind curtailments. These outputs allow for reducing the original market-clearing optimization to a system of linear equations, which can be solved efficiently and yield both the dispatch decisions and the locational marginal prices (LMPs). The dispatch decisions and LMPs are then tested for their feasibility with respect to the requirements for efficient market- clearing results. The accuracy and scalability of the proposed method is tested on a realistic 1814-bus NYISO system with current and future renewable energy penetration levels.
15 June 2022 in IEEE Access
This manuscript reports the first step towards building a robust and efficient model reduction methodology to capture transient dynamics in a transmission level electric power system. Such dynamics is normally modeled on seconds-to-tens-of-seconds time scales by the so-called swing equations, which are ordinary differential equations defined on a spatially discrete model of the power grid. Following Seymlyen (1974) and Thorpe, Seyler, and Phadke (1999), we suggest to map the swing equations onto a linear, inhomogeneous Partial Differential Equation (PDE) of parabolic type in two space and one time dimensions with time-independent coefficients and properly defined boundary conditions. We illustrate our method on the synchronous transmission grid of continental Europe. We show that, when properly coarse-grained, i.e., with the PDE coefficients and source terms extracted from a spatial convolution procedure of the respective discrete coefficients in the swing equations, the resulting PDE reproduces faithfully and efficiently the original swing dynamics. We finally discuss future extensions of this work, where the presented PDE-based modeling will initialize a physics-informed machine learning approach for real-time modeling, $n-1$ feasibility assessment and transient stability analysis of power systems.
1 April 2021 in New Journal of Physics
A wide variety of natural and human-made systems consist of a large set of dynamical units coupled into a complex structure. Breakdown of such systems can have a dramatic impact, as in the case of neurons in the brain or lines in an electric grid, to name but a few. Preventing such catastrophic events requires in particular to be able to detect and locate the source of disturbances as fast as possible. We propose a simple method to identify and locate disturbances in networks of coupled dynamical agents, relying only on time series measurements and on the knowledge of the (possibly Kron-reduced) network structure. The strength and the appeal of the present approach lies in its simplicity paired with the ability to precisely locate disturbances and even to differentiate between line and node disturbances. If we have access to measurement at only a subset of nodes, our method is still able to identify the location of the disturbance if the disturbed nodes are measured. If not, we manage to identify the region of the network where the disturbance occurs.