Diana Patricia Tobón

Diana Patricia Tobón

Auto-generated profile, based on publicly available information

Diana Patricia Tobón

Universidad de Antioquía

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Water, Air, & Soil Pollution
Verified
Journal Article
Open access
PDF file
JBJulio Buelvas
Julio Buelvas
DMDanny Munera
Danny Munera
DVDiana P. Tobón V.
Diana P. Tobón V.
JAJohnny Aguirre
Johnny Aguirre
NGNatalia Gaviria
Natalia Gaviria
With the development of new technologies, particularly Internet of Things (IoT), there has been an increase in the deployment of low-cost air quality monitoring systems. Compared to traditional robust monitoring stations, these systems provide real-time information with higher spatio-temporal resolution. These systems use inexpensive and low-cost sensors, with lower accuracy as compared to robust systems. This fact has raised some concern regarding the quality of the data gathered by the IoT systems, which may compromise the performance of the environmental models. Considering the relevance of the data quality in this scenario, this paper presents a study of the data quality associated with IoT-based air quality monitoring systems. Following a systematic mapping method, and based on existing guidelines to assess data quality in these systems, we have identified the main Data Quality (DQ) dimensions and the corresponding DQ enhancement techniques. After analyzing more than 70 papers, we found that the most common DQ dimensions targeted by the different works are accuracy and precision, which are enhanced by the use of different calibration techniques. Based on our findings, we present a discussion on the challenges that must be addressed in order to improve data quality in IoT-based air quality monitoring systems.

27 August 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AAAmani A Albraikan
Amani A Albraikan
DTDiana P. Tobon
Diana P. Tobon
Abdulmotaleb El SaddikAbdulmotaleb El Saddik
Abdulmotaleb El Saddik
Many techniques have been developed to improve the flexibility and the fit of detection models beyond userdependent models, yet detection tasks continue to be complex and challenging. For emotion, which is known to be highly user-dependent, improvements to the emotion learning algorithm can greatly boost predictive power. Our aim is to improve the accuracy rate of the classifier using peripheral physiological signals. Here, we present a hybrid sensor fusion approach based on a stacking model that allows for data from multiple sensors and emotion models to be jointly embedded within a userindependent model. WMD-DTW, which is a weighted multidimensional DTW, and the k-nearest neighbors algorithm k-NN are used to classify the emotions as a base model. The ensemble methods were used to learn a high-level classifier on top of the two base models. We applied a meta-learning approach to the dataset and showed that the ensemble approach outperforms any individual method. We also compared the results using two datasets. Our proposed system achieved overall accuracies of 65.6% for all users for the E4-dataset and 94.0% and 93.6% for recognizing valence and arousal emotions, respectively, using the MAHNOB dataset.

22 December 2022 in Data
Verified
Journal Article
Open access
PDF file
Mauricio González-PalacioMauricio González-Palacio
Mauricio González-Palacio
DTDiana Tobón-Vallejo
Diana Tobón-Vallejo
LSLina María Sepúlveda-Cano
Lina María Sepúlveda-Cano
Santiago RúaSantiago Rúa
Santiago Rúa
Giovanni PauGiovanni Pau
Giovanni Pau
LLLong Bao Le
Long Bao Le
LoRaWAN is a widespread protocol by which Internet of things end nodes (ENs) can exchange information over long distances via their gateways. To deploy the ENs, it is mandatory to perform a link budget analysis, which allows for determining adequate radio parameters like path loss (PL). Thus, designers use PL models developed based on theoretical approaches or empirical data. Some previous measurement campaigns have been performed to characterize this phenomenon, primarily based on distance and frequency. However, previous works have shown that weather variations also impact PL, so using the conventional approaches and available datasets without capturing important environmental effects can lead to inaccurate predictions. Therefore, this paper delivers a data descriptor that includes a set of LoRaWAN measurements performed in Medellín, Colombia, including PL, distance, frequency, temperature, relative humidity, barometric pressure, particulate matter, and energy, among other things. This dataset can be used by designers who need to fit highly accurate PL models. As an example of the dataset usage, we provide some model fittings including log-distance, and multiple linear regression models with environmental effects. This analysis shows that including such variables improves path loss predictions with an RMSE of 1.84 dB and an R2 of 0.917.

12 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IAIzaldein Al-Zyoud
Izaldein Al-Zyoud
Fedwa LaamartiFedwa Laamarti
Fedwa Laamarti
XMXiaocong Ma
Xiaocong Ma
DTDiana Tobón
Diana Tobón
Abdulmotaleb El SaddikAbdulmotaleb El Saddik
Abdulmotaleb El Saddik
Human bio-signal fusion is considered a critical technological solution that needs to be advanced to enable modern and secure digital health and well-being applications in the metaverse. To support such efforts, we propose a new data-driven digital twin (DT) system to fuse three human physiological bio-signals: heart rate (HR), breathing rate (BR), and blood oxygen saturation level (SpO2). To accomplish this goal, we design a computer vision technology based on the non-invasive photoplethysmography (PPG) technique to extract raw time-series bio-signal data from facial video frames. Then, we implement machine learning (ML) technology to model and measure the bio-signals. We accurately demonstrate the digital twin capability in the modelling and measuring of three human bio-signals, HR, BR, and SpO2, and achieve strong performance compared to the ground-truth values. This research sets the foundation and the path forward for realizing a holistic human health and well-being DT model for real-world medical applications.

30 November 2024 in Internet of Things
Verified
Journal Article
Open access
MRMartha Rodríguez
Martha Rodríguez
DTDiana P. Tobón
Diana P. Tobón
DMDanny Munera
Danny Munera

4 December 2017 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
DTDiana P. Tobon
Diana P. Tobon
SJSrinivasan Jayaraman
Srinivasan Jayaraman
TFTiago Henrique Falk
Tiago Henrique Falk
The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training).