Zhiqiang Zhu

Zhiqiang Zhu

Auto-generated profile, based on publicly available information

Zhiqiang Zhu

Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
ZZZhiqiang Zhu
Zhiqiang Zhu
CSCao Songyin
Cao Songyin
In this article, a fault tolerant controller (FTC) based on back‐stepping sliding mode is proposed for a quadrotor unmanned aerial vehicle (UAV) with single‐rotor failure. According to the working mechanism of the quadrotor, the control system of UAV is divided into position subsystem and attitude subsystem. Then, the yaw control is abandoned because of the increased underactuation. The controller is designed by the back‐stepping sliding mode control (BSMC). BSMC is robust to system uncertainties and external disturbances. Sliding mode reaching law is designed. Therefore, it can reduce system chattering. Based on the Lyapunov function method, the proposed FTC approach makes the faulty UAV stable and realises position control accuracy. Finally, simulation results show that the quadrotor UAV can reach the desired position and maintain the hover state, which verifies the effectiveness of the proposed method.

4 July 2019 in Fusion Engineering and Design
Verified
Journal Article
Closed access
MKMuhammad Khan
Muhammad Khan
ZZZhiqiang Zhu
Zhiqiang Zhu
QHQunying Huang
Qunying Huang

6 April 2020 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
QHQunying Huang
Qunying Huang
ZZZhiqiang Zhu
Zhiqiang Zhu
FTFds Team
Fds Team

30 July 2015 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
ZMZi Meng
Zi Meng
Ni MuyiNi Muyi
Ni Muyi
JJJieqiong Jiang
Jieqiong Jiang
ZZZhiqiang Zhu
Zhiqiang Zhu
TZTao Zhou
Tao Zhou

12 March 2018 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
SHShaoqiu Huang
Shaoqiu Huang
ZZZhiqiang Zhu
Zhiqiang Zhu
WHWangli Huang
Wangli Huang

19 May 2016 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
XLX L Li
X L Li
XMX D Ma
X D Ma
ZZZ Q Zhu
Z Q Zhu
YLY Li
Y Li
KLK F Lv
K F Lv
Pump is a key sub-system which drives the heavy liquid metal circulation in experimental loops. In the paper, the hydraulic and mechanical performances of an electromagnetic pump (EMP) were tested in the liquid metal test facility named PREKY-I. The test results showed that the EMP worked at good state when the working current was up to 170 ampere. In this condition, the flow rate was 5m3/h, and pressure head 7.5bar, when the outlet temperature was kept at 380°C during the test. The performance was close to the expected design parameters. The EMP had run continuously for 200 hours with stable performance. From the test results, the EMP could be used in KYLIN-II loop, which is the upgrade liquid metal test loop of PREKY-I.