Lina Hasenko

Lina Hasenko

Auto-generated profile, based on publicly available information

Lina Hasenko

National University “Yuri Kondratyuk Poltava Polytechnic

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Periodica Polytechnica Transportation Engineering
Verified
Journal Article
Closed access
PDF file
TLTetyana Lytvynenko
Tetyana Lytvynenko
ITIryna Tkachenko
Iryna Tkachenko
LGLina Gasenko
Lina Gasenko

1 January 2015 in Periodica Polytechnica Transportation Engineering
Verified
Journal Article
Open access
PDF file
TLTetyana Lytvynenko
Tetyana Lytvynenko
LGLina Gasenko
Lina Gasenko
Peculiarities of Infrastructure Designing for the Movement of Individual Environmental Friendly Vehicles


30 March 2020 in Periodica Polytechnica Transportation Engineering
Verified
Journal Article
Open access
PDF file
ITIryna Tkachenko
Iryna Tkachenko
TLTetyana Lytvynenko
Tetyana Lytvynenko
DPDmitry Prusov
Dmitry Prusov
LHLina Hasenko
Lina Hasenko
The work is devoted to placement of streets and urban roads greening elements. The statistics of the road traffic fatalities rate as a result of ride on obstruction, in particular a tree in Ukraine, Poland, the USA, Denmark, have been analyzed. An unsatisfactory situation in Ukraine was confirmed, where the accident rate on roads with a fatal outcome is almost 10 times higher than in the safest countries of the world. The main functions of the streets and urban roads greening elements are generalized. There are: environmental protection (noise absorption, air purification from exhaust gases and pollination); decorating (creation of space for satisfaction of esthetic requirements of a person); accentuating; barrier etc. The greening elements of Ukraine streets and urban roads are classified and compared with the classifications of Queensland (Australia) and Poland. Current placement of greening elements in Poltava (Ukraine) streets was analyzed and the main disadvantages of placing greening elements were revealed. The normative requirements for the street and urban road greening elements placement in Ukraine, Queensland (Australia), Poland, Sweden, Denmark have been analyzed. Existing placement of the street and urban road greening elements in countries with high level of traffic safety were researched and the ways of improvement of existing street greening in Ukraine was found.

19 December 2023
Verified
Book Chapter
Closed access
PDF file
ITIryna Tkachenko
Iryna Tkachenko
TPTetiana Pavlenko
Tetiana Pavlenko
TLTetyana Lytvynenko
Tetyana Lytvynenko
LHLina Hasenko
Lina Hasenko
BKBohdan Kupriienko
Bohdan Kupriienko

24 December 2021 in Збірник наукових праць Галузеве машинобудування будівництво/ Academic journal Industrial Machine Building Civil Engineering
Verified
Journal Article
Open access
PDF file
Oleksandr SemkoOleksandr Semko
Oleksandr Semko
OFOlena Filonenko
Olena Filonenko
LHLina Hasenko
Lina Hasenko
Nataliia MahasNataliia Mahas
Nataliia Mahas
VRViktor Rudenko
Viktor Rudenko
The article presents the experience of developing engineering solutions for the restoration and preservation of cold pitched attic structures on the example of a historic building in Poltava. A preliminary design solution for the thermal modernization of the attic floor was analyzed, which included the placement of mineral wool insulation in the attic in accordance with requirements of DBN V.2.6-31:2016 with a thickness of 250 mm. Increasing the thickness of the insulation to modern requirements for energy efficiency on a reinforced concrete floor could lead to a decrease in the temperature in the attic, which, in turn, would not contribute to the melting of snow on the roof, which occurred in the last 70 years of the building's operation. A possible increase in snow load along with cooling of the steel truss elements to -20°C can cause brittle fracture of truss elements made of boiling steel. The thickness of the insulation along the attic floor should be taken no more than 100 mm in order to reduce transmission heat losses and maintain a positive temperature in the attic space.