26 August 2019 in Optics Letters
This Letter proposes a simple and practical approach for numerical aperture measurement of immersion objectives. The basic concept is to generate a reference on the spectral plane and then apply the Abbe sine condition to evaluate the numerical aperture. An extremely cheap, simple but effective and practical example is to locate a coverslip on the focal plane and then record the resulting back focal plane, on which the total internal reflection ring is applied as the reference. To achieve higher repeatability and impose fewer requirements on both the operation procedure and experiment conditions, we propose an algorithm mainly consisting of two-dimensional Fourier correlation analysis and grayscale statistics to automatically identify the radii of total internal reflection and clear aperture. The proposed approach is further applied in the measurement of an objective lens with adjustable pupils when surface plasmon is employed as reference. Experimental verification is provided.
1 November 2019 in Optics Communications
2 November 2020 in IEEE Transactions on Instrumentation and Measurement
A solid immersion objective is generally composed of a truncated solid ball and a commercial objective lens. It features on higher numerical aperture (NA) than oil-immersion objectives and thus shows capabilities in some applications requiring higher NA or spatial resolutions. Different from commercial products of oil-immersion objectives and their pre-labelled NA values, solid immersion objective is generally home-designed/developed, and the theoretical NA is taken as its practical value, which is not suggested. So far, there has been no proper and commercial apparatus to measure this NA value especially for bare solid immersion objectives. In this work, we propose an extremely simple but very practical approach for the measurement, which inherits the concept of Fourier optics but offers some specific features. Furthermore, we specifically propose an algorithm of multi-point reference to achieve high accuracy of NA value. Detailed comparisons between the proposed algorithm and the previous algorithm of single-point reference are elaborated. An experimental prototype of apertometer for solid immersion objective is built up to verify the proposed approach and algorithm. To the best of the authors’ knowledge, this is the simplest, cheapest, and most practical approach and apparatus for the NA measurement of bare solid immersion objective.
25 September 2021 in Nano
9 April 2021 in IEEE Transactions on Instrumentation and Measurement
Objective-coupled surface plasmon microscopy (SPM) features on both extremely high sensitivity and high resolution. However, this promising system is still operated in labs without commercial instrument. One big challenge is how to extract and classify the plasmonic signals from batches of experimentally acquired back focal plane (BFP) images accurately and automatically. To solve this problem, this work presents a complete solution for the first time which significantly promotes the application and instrumentation of BFP typed SPM in two aspects: 1) It utilizes an object detection model to pre-determine the classification and raw localization of plasmonic absorption profiles for the convenience of subsequent fine detection. 2) It utilizes self-correlation to identify the plasmonic signal more accurately; When the mode of plasmonic signal is determined, the self-correlation procedure can operate independently, with faster speed and wider applicability than our previously proposed Fourier correlation analysis. The whole scheme is experimentally verified on our home-developed SPM. And the performance of the proposed scheme is illustrated through comparisons with other approaches.
28 October 2020 in IEEE Photonics Journal
Objective-coupled surface plasmon microscopy (SPM) shows extremely high similarity with conventional optical microscopy (OM) in both configuration and theoretical model. And there is a common misunderstanding in SPM that all the three polarization components Ex, Ey, and Ez of the focused beam contribute to excitation of SPs, similar as the situation in OM that all the polarization components generate image contrast. Actually, this is not the case and some literatures have suggested ‘only Ez excites SPs’. However, so far there has been no related theory to support this issue, and the common misunderstanding and corresponding errors are still applied in both academia and industry. The present work clarifies this significant issue for the first time. We theoretically prove that ‘only Ez excites SPs’ and further give two related phenomena as evidences.