Xiaoqi Zhang

Xiaoqi Zhang

Auto-generated profile, based on publicly available information

Xiaoqi Zhang

Cheeloo College of Medicine, Shandong University, Jinan, 250012, Shandong, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Arthroplasty Today
Verified
Journal Article
Open access
PDF file
XZXiaoqi Zhang
Xiaoqi Zhang
FHFei Hu
Fei Hu
RHRui He
Rui He
XLXu Li
Xu Li
XJXiaofeng Ji
Xiaofeng Ji
XSXifu Shang
Xifu Shang
Removing well-fixed acetabular components, occurring for reasons such as infection, recurrent dislocation, polyethylene wear, and bony impingement, can be a challenge for orthopaedic surgeons in revision of total hip arthroplasty. The purpose of revision is reconstructing form and function of hip joints. Acetabular bone loss and compromised reimplantation often occur in removing procedure of acetabular components. Several bone conservative techniques have been described to reduce difficulties of the operation [ 1 x [1] Olyslaegers, C., Wainwright, T., and Middleton, R.G. A novel technique for the removal of well-fixed cementless, large-diameter metal-on-metal acetabular components. J Arthroplasty. 2008; 23: 1071 Abstract | Full Text | Full Text PDF | PubMed | Scopus (11) | Google Scholar See all References , 2 x [2] Taylor, P.R., Stoffel, K.K., Dunlop, D.G., and Yates, P.J. Removal of the well-fixed hip resurfacing acetabular component: a simple, bone preserving technique. J Arthroplasty. 2009; 24: 484 Abstract | Full Text | Full Text PDF | PubMed | Scopus (9) | Google Scholar See all References , 3 x [3] Daum, W.J. and Calhoun, J.H. Removal of the acetabular component minimizing destruction of the bone bed. J Arthroplasty. 1988; 3: 379 Abstract | Full Text PDF | PubMed | Scopus (10) | Google Scholar See all References , 4 x [4] Markovich, G.D., Banks, S.A., and Hodge, W.A. A new technique for removing noncemented acetabular components in revision total hip arthroplasty. Am J Orthop. 1999; 28: 35 PubMed | Google Scholar See all References ]. Based on development and diversity of implant components, a simple and efficient technique for extracting implants is necessary.


7 August 2025 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
XZXiaoqi Zhang
Xiaoqi Zhang
GLGuoyuan Li
Guoyuan Li
MCMin Chen
Min Chen
ZNZhe Ni
Zhe Ni
ZLZhengliang Luo
Zhengliang Luo
XSXifu Shang
Xifu Shang
Novel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications. Nine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN). All constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value. The study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.