24 June 2020 in Bioscience Reports
Purpose: During surgical procedure on lumbar spondylolisthesis, the role of reducing slip remains controversial. The purpose of the present study was to compare fusion in situ with reduction in clinical and radiographic outcomes. Methods: A literature research was performed at PubMed, Embase, Web of Science, and Cochrane Library. After screening by two authors, ten articles were brought into this meta-analysis finally, and the quality was evaluated by the modified Newcastle–Ottawa Scale (NOS). Isthmic, moderate, and serious spondylolisthesis were all analyzed separately. Sensitivity analyses were performed for high-quality studies, and the publication bias was evaluated by the funnel plot. Results: Most criteria did not have statistical differences between reduction and fusion in situ groups. However, in reduction group, the union rate was significantly higher (P=0.008), the slippage was much improved (P<0.001) and the hospital stay was much shorter comparing to no-reduction group (P<0.001). Subgroup analysis (containing moderate and serious slip, or isthmic spondylolisthesis) and sensitivity analysis were all consistent with original ones, and the funnel plot indicated no obvious publication bias in this meta-analysis. Conclusions: Both reduction and fusion in situ for lumbar spondylolisthesis were related with good clinical results. Reduction led to higher rate of fusion, better radiographic slippage, and shorter hospital stay. After sufficient decompression, reduction did not incur additional risk of neurologic impairment compared with fusion in situ.
7 August 2025 in BMC Musculoskeletal Disorders
Novel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications. Nine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN). All constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value. The study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.