Aivars Pumpurs

Aivars Pumpurs

Auto-generated profile, based on publicly available information

Aivars Pumpurs

Institute of Industrial Electronics and Electrical Engineering, Riga Technical University, Azenes iela 12/1, Riga , LV-1048, Latvia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Environmental and Climate Technologies
Verified
Journal Article
Open access
EBEdite Biseniece
Edite Biseniece
RFRitvars Freimanis
Ritvars Freimanis
RPReinis Purvins
Reinis Purvins
AGArmands Gravelsins
Armands Gravelsins
APAivars Pumpurs
Aivars Pumpurs
ABAndra Blumberga
Andra Blumberga
Being an important contributor to the final energy consumption, historic buildings built before 1945 have high specific heating energy consumption compared to current energy standards and norms. However, they often cannot be insulated from the outside due to their heritage and culture value. Internal insulation is an alternative. However internal insulation faces challenges related to hygrothermal behaviour leading to mold growth, freezing, deterioration and other risks. The goal of this research is to link hygrothermal simulation results with experimental results for internally insulated historic brick masonry to assess correlation between simulated and measured data as well as the most influential parameters. The study is carried out by both a mathematical simulation tool and laboratory tests of historic masonry with internal insulation with four insulation materials (mineral wool, EPS, wood fiber and granulated aerogel) in a cold climate (average 4000 heating degree days). We found disparity between measured and simulated hygrothermal performance of studied constructions due to differences in material parameters and initial conditions of materials. The latter plays a more important role than material parameters. Under a steady state of conditions, the condensate tolerating system varies between 72.7 % and 80.5 % relative humidity, but in condensate limiting systems relative humidity variates between 73.3 % and 82.3 %. The temperature between the masonry wall and all insulation materials has stabilized on average at +10 °C. Mold corresponding to Mold index 3 was discovered on wood fiber mat.

1 October 2015
Verified
Conference Paper
Closed access
GZGenadijs Zaleskis
Genadijs Zaleskis
ISIngars Steiks
Ingars Steiks
APAivais Pumpurs
Aivais Pumpurs
OKOskars Krievs
Oskars Krievs
This paper is related to autonomous wind power system with typical power demand of 2 to 5kW. Presented power system is designed for private houses or small farms. In the case of low wind speed the energy is provided by energy storage, in mentioned system for this purpose the hydrogen fuel cell was chosen. The main purpose of this paper is to find optimal solutions for creation and control of DC/AC converter used for load supply in the autonomous power supply system. To make the power system more economically profitable the utilization of the heat of fuel cell cooling system should be accomplished. Various new-trend control methods should be implemented of the single-phase 5-level NPC converter therefore decreasing the size of the output filter compared to the implemented classical PWM method.

1 October 2016
Verified
Conference Paper
Closed access
APAivars Pumpurs
Aivars Pumpurs
LRLeonīds Ribickis
Leonīds Ribickis
This paper describes the use of smart materials and adaptronic control concepts in small size robots. Small size in this specific research means that robot hand have the span from several centimeters to some tens of centimeters. The possibility of building robot mechanics using different kind of smart materials are analyzed. There is no target to build the specific robot, but the possible solutions are analyzed. The control method for SMA (Shape Memory Alloy) actuator is proposed. The method for estimating temperature inside the SMA sample is described. The experimental setup is built up and the test measurements are made. The dynamics of control and the energy consumption of proposed control method are analyzed.