Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
Auto-generated profile, based on publicly available information
Shuangquan Liu
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
Purpose: To automatically extract regions of interest (ROIs) and simultaneously preserve the anatomical characteristics of each individual, we developed a new atlas‐based method utilizing a pair of coregistered brain template and digital atlas.Materials and Methods: Unlike the previous atlas‐based method, this method treats each individual as the target image, and the template and atlas are each transformed to register with the individual. To evaluate the accuracy of this method we implemented it in extracting the hippocampus from two groups of T2‐weighted structural images with different spatial resolutions and a group of T2*‐weighted functional images. Furthermore, the results were compared against a manually segmented hippocampus and an atlas‐derived hippocampus.Results: Jaccard similarity (JS) reached 84.7%–90.5%, and relative error in volume (RV) was 4.8%–12.7%. The consistency observed between the results of the proposed method and manual drawing was therefore considerable.Conclusion: We developed a new atlas‐based method for ROI extraction that can automatically extract ROI and simultaneously preserve each individual's unique anatomical characteristics. J. Magn. Reson. Imaging 2010;32:830–835.
1 April 2012 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
A dual-modality imaging system for simultaneous fluorescence molecular tomography (FMT) and positron emission tomography (PET) of small animals has been developed. The system consists of a noncontact 360°-projection FMT module and a flat panel detector pair based PET module, which are mounted orthogonally for the sake of eliminating cross interference. The FMT images and PET data are simultaneously acquired by employing dynamic sampling mode. Phantom experiments, in which the localization and range of radioactive and fluorescence probes are exactly indicated, have been carried out to verify the feasibility of the system. An experimental tumor-bearing mouse is also scanned using the dual-modality simultaneous imaging system, the preliminary fluorescence tomographic images and PET images demonstrate the in vivo performance of the presented dual-modality system.
This work presents a novel stereo coded aperture gamma camera based on four detection modules placed within four quadrants. Each module includes 48 × 48 strips of Bi4Ge3O12 scintillators, 24 × 24 pieces of silicon photomultipliers (SiPMs), and a set of data acquisition circuits. All signals from the SiPMs are individually extracted and finally simplified into 144 outputs to calculate the positions and energies of gamma-rays. Two masks of modified uniformly redundant arrays are fixed in the front of the top-right and bottom-left modules and two anti-masks are fixed in the top-left and bottom-right modules to achieve simultaneous imaging without dual measure. Once the projections of radioactive sources are determined, their source-to-detector distances can be estimated by our new multocular ranging algorithm. A series of lab and field experiments, including flood histogram and energy spectrum testing, field-of-view and angular resolution testing, real-time imaging, long-distance imaging, and ranging ability testing, with different radioactive sources, such as 137Cs, 22Na, 241Am, 60Co, 133Ba, and 75Se, have been completed to evaluate the comprehensive ability of the stereo gamma camera. The results show that the stereo gamma camera has a strong ability for the three-dimensional localization of radioactive sources over long distances with a high image sensitivity. So far, the stereo gamma camera has been successfully used in practical nuclear security and safety tasks although the angular resolution and the ranging algorithm robustness should be more optimized in the future.
30 January 2013 in IEEE Transactions on Multimedia
In this paper, fluorescence molecular tomography (FMT) imaging guided by priors from simultaneous positron emission tomography (PET) was performed on a multi-modality imaging system combining PET and FMT. The target prior information from PET images was employed to the FMT reconstruction procedure using the iteratively reweighted least-squares method. Numerical simulations and phantom experiments were performed to validate the proposed method. The results indicate that incorporating the PET prior information into the FMT reconstruction can potentially improve the spatial resolution of FMT.