Chunmiao Li

Chunmiao Li

Auto-generated profile, based on publicly available information

Chunmiao Li

Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences 1 , Beijing 100049, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
CLChunmiao Li
Chunmiao Li
SLShuangquan Liu
Shuangquan Liu
CWChao Wang
Chao Wang
XJXiaopan Jiang
Xiaopan Jiang
XSXiaoli Sun
Xiaoli Sun
LWLong Wei
Long Wei

1 November 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LKLingqin Kong
Lingqin Kong
LSLei Shuai
Lei Shuai
XLXiuzuo Liang
Xiuzuo Liang
DLDaowu Li
Daowu Li
JZJipeng Zhang
Jipeng Zhang
LWLong Wei
Long Wei
In this study, we propose a hybrid coded-aperture and Compton camera based on cerium-doped Gd3Al2Ga3O12 (GAGG:Ce) scintillator arrays coupled with Multi-Pixel Photon Counter (MPPC) arrays. The sensitive detector of the gamma camera consists of a single GAGG:Ce crystal coupled with a single-chip MPPC unit module. An impedance bridge circuit and a 64-channel data acquisition system were employed to record the code-aperture events and Compton coincidence events. After the calibration of position and energy, the total energy resolution for 662 keV gamma-rays from 137Cs was 6.6%. The hybrid camera had the characteristics of mechanical collimation and electronic collimation at the same time. In the code aperture mode, the reconstructed images were obtained by direct deconvolution and maximum likelihood expectation maximization (MLEM) methods. In the Compton imaging mode, the energy-dependent method was applied to order the sequence of Compton scatter events. The simple back-projection algorithm and list-mode MLEM algorithm were adopted for image reconstruction. Practical performances demonstrated that the angular resolutions in two modes were measured as 5.2° and 11.4°, respectively. In addition, the hybrid camera had a desirable imaging capability in a wide energy range (32 keV–2.6 MeV) and a wide field of view (∼210° in the horizontal direction). As for the sensitivity, the camera had a commercially available sensitivity level of localizing a 137Cs point source, producing ∼0.026 µSv/h in 5 min. Furthermore, the function of distinction for different radiation sources was preliminarily realized.