Abolfazl Soltani

Abolfazl Soltani

Auto-generated profile, based on publicly available information

Abolfazl Soltani

Laboratory of Movement Analysis and Measurement (LMAM), EPFL, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
ASAbolfazl Soltani
Abolfazl Soltani
HDHooman None Dejnabadi
Hooman None Dejnabadi
MSMartin Albert Savary
Martin Albert Savary
Kamiar AminianKamiar Aminian
Kamiar Aminian
Gait speed is an important parameter to characterize people's daily mobility. For real-world speed measurement, inertial sensors or Global Navigation Satellite System (GNSS) can be used on wrist, possibly integrated in a wristwatch. However, power consumption of GNSS is high and data are only available outdoor. Gait speed estimation using wrist-mounted inertial sensors is generally based on machine learning and suffers from low accuracy due to the inadequacy of using limited training data to build a general speed model that would be accurate for the whole population. To overcome this issue, a personalized model was proposed, which took unique gait style of each subject into account. Cadence and other biomechanically-derived gait features were extracted from wrist-mounted accelerometer and barometer. Gait features were fused with few GNSS data (sporadically sampled during gait) to calibrate the step length model of each subject through online learning. The proposed method was validated on 30 healthy subjects. For walking, it has achieved a median [Interquartile Range] RMSE, bias and precision of 0.05 [0.04-0.06], 0.00 [-0.01 0.00], and 0.06 [0.05 0.07] (m/s), respectively. For running, the errors are 0.14 [0.11 0.17], 0.00 [-0.01 0.02], and 0.18 [0.14 0.23] (m/s), respectively. Results demonstrated that the personalized model provided similar performance as GNSS. It used 50 times less training GNSS data than non-personalized method and achieved even better results. This parsimonious GNSS usage allowed extending battery life. The proposed algorithm met requirements for applications which need accurate, long, real-time, low-power, and indoor/outdoor speed estimation in daily life.

10 September 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ASA. Soltani
A. Soltani
Kamiar AminianKamiar Aminian
Kamiar Aminian
Claudia MazzàClaudia Mazzà
Claudia Mazzà
ACA. Cereatti
A. Cereatti
LPLuca Palmerini
Luca Palmerini
APAnisoara Paraschiv-Ionescu
Anisoara Paraschiv-Ionescu
Walking/gait speed is a key measure for daily mobility characterization. To date, various studies have attempted to design algorithms to estimate walking speed using an inertial sensor worn on the lower back, which is considered as a proper location for activity monitoring in daily life. However, these algorithms were rarely compared and validated on the same datasets, including people with different preferred walking speed. This study implemented several original, improved, and new algorithms for estimating cadence, step length and eventually speed. We designed comprehensive cross-validation to compare the algorithms for walking slow, normal, fast, and using walking aids. We used two datasets, including reference data for algorithm validation from an instrumented mat (40 subjects) and shanks-worn inertial sensors (88 subjects), with normal and impaired walking patterns. The results showed up to 50% performance improvements. Training of algorithms on data from people with different preferred speeds led to better performance. For the slow walkers, an average RMSE of 2.5 steps/min, 0.04 m, and 0.10 m/s were respectively achieved for cadence, step length, and speed estimation. For normal walkers, the errors were 3.5 steps/min, 0.08 m, and 0.12 m/s. An average RMSE of 1.3 steps/min, 0.05 m, and 0.10 m/s were also observed on fast walkers. For people using walking aids, the error significantly increased up to an RMSE of 14 steps/min, 0.18 m, and 0.27 m/s. The results demonstrated the robustness of the proposed combined speed estimation approach for different speed ranges. It achieved an RMSE of 0.10, 0.18, 0.15, and 0.32 m/s for slow, normal, fast, and using walking aids, respectively.

1 June 2020 in IEEE Access
Verified
Journal Article
Open access
ASAbolfazl Soltani
Abolfazl Soltani
APAnisoara Paraschiv-Ionescu
Anisoara Paraschiv-Ionescu
HDHooman Dejnabadi
Hooman Dejnabadi
PMPedro Marques-Vidal
Pedro Marques-Vidal
KAKamiar Aminian
Kamiar Aminian
Gait bouts (GB), as a prominent indication of physical activity, contain valuable fundamental information closely associated with human’s health status. Therefore, objective assessment of the GB (e.g. detection, spatio-temporal analysis) during daily life is very important. A feasible and effective way of GB detection in real-world situations is using a wrist-mounted inertial measurement unit. However, the high degree of freedom of the wrist movements during daily-life situations imposes serious challenges for a precise and robust automatic detection. In this study, we deal with such challenges and propose an accurate algorithm to detect GB using a wrist-mounted accelerometer. Features, derived based on biomechanical criteria (intensity, periodicity, posture, and other non-gait dynamicity), along with a Bayes estimator followed by two physically-meaningful post-classification procedures are devised to optimize the performance. The proposed method has been validated against a shank-based reference algorithm on two datasets (29 young and 37 elderly healthy people). The method has achieved a high median [interquartile range] of 90.2 [80.4, 94.6] (%), 97.2 [95.8, 98.4] (%), 96.6 [94.4, 97.8] (%), 80.0 [65.1, 85.9] (%) and 82.6 [72.6, 88.5] (%) for the sensitivity, specificity, accuracy, precision, and F1-score of the detection of GB, respectively. Moreover, a high correlation (R2 = 0.95) was observed between the proposed method and the reference for the total duration of GB detected for each subject. The method has been also implemented in real time on a low power consumption prototype.

1 January 2016 in Neurocomputing
Verified
Journal Article
Closed access
ASAbolfazl Soltani
Abolfazl Soltani
SASeyed Mohammad Ahadi
Seyed Mohammad Ahadi
NFNeda Faraji
Neda Faraji
SSSaeed Sharifian
Saeed Sharifian