3 September 2024 in IEEE Transactions on Power Electronics
Linear extended state observer (LESO) plays a critical role in ADRC's control performance. However, there exists a tradeoff between disturbance rejection and noise immunity for traditional linear ESO (TLESO). Compared to TLESO with similar bandwidth, phase-locking loop observer (PLLO) exhibits a better output tracking performance but weaker noise suppression capability. By combining the advantages of TLESO and PLLO, an adaptive LESO (ALESO) is proposed in this article, which utilizes TLESO in steady state and PLLO during transient state. The dynamic and noise-suppression performances of different observers are analyzed and compared systematically. The proposed ALESO inherits good dynamic response of PLLO and noise-suppression performance of TLESO, without using high bandwidth. It also possesses the advantages of simple structure, requiring few tuning parameters and ease of parameter tuning. To verify the feasibility and effectiveness of the proposed ALESO design, it is employed to a 500 W dual-active-bridge dc–dc converter for pulsed power applications. Experiments results show that, in comparison with TLESO, the proposed ALESO has resulted in 33.3%/37% and 60%/73.3% reductions in output voltage undershoot/overshoot and setting time, respectively, under load step-up/down. For steady-state performance, a noise level reduction of 76.3% is achieved compared to that resulting from PLLO.
4 June 2025 in IEEE Transactions on Power Electronics
The power supply for pulsed power loads demands exceptional dynamic performance, requiring fast and precise regulation of the output voltage. Active disturbance rejection control (ADRC) with a linear extended state observer (LESO) stands out among control strategies due to its model independence and simplified parameter design. A crucial element of ADRC is the LESO, which effectively tracks total disturbances with limited system information. However, the LESO’s tracking speed is constrained by the crossover frequency, and it exhibits significant steady-state errors when disturbances take the form of ramp, acceleration, or sinusoidal function. To enhance the speed and accuracy of disturbance tracking, a series-correction-based LESO incorporating an incomplete differential proportional-integral-derivative (PID) controller is proposed for an ADRC-controlled dual active bridge (DAB) converter. The proposed optimized LESO offers a faster dynamic response and smaller steady-state errors compared to traditional LESO. Additionally, the article addresses system stability and parameter optimization for the improved converter. The effectiveness of the optimized LESO design is validated using a 500W DAB experimental prototype, demonstrating excellent dynamic response and low susceptibility to parameter variations.
7 August 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Analyzing the stability of dual active bridge (DAB) converters is of great significance for ensuring reliable system operation. The introduction of active disturbance rejection control (ADRC) presents new challenges in the stability analysis of DAB converters, while constant power loads (CPLs), with negative impedance characteristics, further complicate the design of system parameters. These challenges have not been thoroughly explored. To address these issues, this paper proposes a model of a DAB converter controlled by ADRC and supplying a CPL. A small-signal analysis is conducted using Lyapunov’s first method, complemented by numerical simulation verification. The maximum permissible step change in load power is estimated using numerical simulation, with results validated by estimating the system’s asymptotically stable region. Parameter design strategies are also discussed to enhance both small-signal and large-signal stability. Finally, experimental verification is performed, and valuable conclusions are given.