2 December 2025 in IEEE Transactions on Plasma Science
The concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa $\cdot $ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.
14 July 2025 in Nuclear Fusion
The ability to provide fusion burn control without requiring physical access through the first wall and fuel breeding blankets, would be vital for any future, magnetically confined fusion power reactor. A multi-sensor, fusion fuel cycle exhaust, neutral gas analysis system on JET, capable of delivering real time data, and accessing only the sub-divertor region, provides an excellent example of such capability. Optimized for and operated during the deuterium–tritium experimental campaigns 2 and 3 (DTE2, DTE3), it is proving valuable for planning to explore fusion reactor burn control in ITER with a comparable diagnostic system called the Diagnostic Residual Gas Analyzer (DRGA). This paper aims to show feasibility of developing model-based controllers for ITER and next generation, reactor-relevant devices, by building both on the empirical experience in JET-DTE2, and on the already emerging experience on developing such models specifically for ITER. The paper begins with a specific use-case from JET-DTE2, pertaining to the observed sensitivity of the fusion neutron yield on the concentration of isotopic helium-3 (3He), with data from one of the high-performance DT shots exhibited with emphasis on the 3He measurement via the sub-divertor. Then, a first model is developed and then explored with simulations that aim to discover how well the controllers in the model react to either insufficient levels of 3He or excessive levels of 3He. The simulations then explore potential impact from a delay in the measurement (or the response) that would be comparable to the ∼1 s, conductance limited response for the ITER DRGA system, currently in its final design. The simulations show that control is feasible, and that its effectiveness is not significantly impacted by such delay.
23 April 2024 in IEEE Transactions on Plasma Science
Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.
22 May 2026 in IEEE Transactions on Plasma Science
Analysis of the ITER diagnostic residual gas analyzer (DRGA) vacuum system is critical for the design and accuracy of the gas composition measurement which is used for the control of plasma heating and fuel-cycle processing. The DRGA is a diagnostic system capable of resolving hydrogen and helium isotopes as well as heavier impurity gases. The DRGA is located approximately 15 m away from the divertor and is intended to measure the composition of gases in the ITER sub-divertor region. The DRGA for the divertor analysis relies on an evacuated sampling pipe to transport the exhaust gases to the analysis station where spectrometers measure the exhaust gas composition. At the sampling pipe entrance, an in-line orifice creates molecular flow conditions in the entire length of the sampling pipe. For plasma heating control and fuel-cycle processing, it is necessary to analyze the time-dependent response resulting from changes in gas composition from injected gas and/or fueling pellets. Molflow+, which is a test particle Monte Carlo (TPMC) simulation code, is used to simulate the time-dependent response of the DRGA from injections of hydrogen gas. An innovative way to model an in-line turbomolecular pump is presented in this work. The results from a simulation code based on the physical geometry of an in-lab test article. The results from the simulation code and physical testing of the in-lab test article are compared and show good agreement. The simulation is then extended to an ITER like geometry and compared to previous work. The results of the time dependent response are shown from the sampling pipe orifice to the RGA and a plasma cell which is used for optical gas analysis (OGA) which are two distinct locations in the DRGA system, and the latter of these locations has not been simulated previously. This study provides important design validation of the ITER DRGA time-dependent response as it relates to fuel-cycle and plasma heating control.
23 January 2026 in Nuclear Materials and Energy
1 October 2026 in Review of Scientific Instruments
The (ITER-prototype) diagnostic residual gas analyzer (p-DRGA) was deployed in the W7-X OP2.3 experimental campaign, with emphasis on W7-X research applications, i.e., going beyond diagnostic capability demonstration focus of the previous campaigns. In addition to an initial validation of neutrals modeling in sub-divertor regions for helium exhaust applications and support of the associate ICRF-induced fast ion generation research program, the diagnostic system also provided early data relevant to an envisioned DRGA-enabled, stellarator reactor-relevant, fusion plasma burn control study, to be extended in OP2.4 and beyond. In this extended study concept, the fast ion generation would serve as proxy to the ICRF-enhanced DT burn approach used in JET-DTE2/DTE3, while the DRGA will provide the relevant species concentrations in real-time. Implicit in this concept is the correlation between core and sub-divertor concentrations, in ∼few sec equilibration time, which still needs validation for the case of stellarators.