Bowen Lv

Bowen Lv

Auto-generated profile, based on publicly available information

Bowen Lv

College of Engineering and Design, Hunan Normal University, Changsha, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BLBowen Lv
Bowen Lv
YQYanding Qin
Yanding Qin
HDHoude Dai
Houde Dai
SSShijian Su
Shijian Su
Magnetic localization technique has the advantages of millimeter-level localization accuracy, fast localization speed, and no limit-of-sight constraints. However, most studies are limited to the tracking of single or two magnets because of the low localization success rate for multiple magnets, thereby restricting its application scenarios. In this study, a novel multi-magnetic target localization method, named individual memory-based whale optimization and Levenberg-Marquardt (IMWO-LM) algorithm, is proposed to overcome the problem of low localization success rate. The IMWO algorithm adds the individual historical optimal location memory to each whale, which improves the global search ability of the population. This IMWO algorithm result is employed as the initial guess of the LM method. Afterward, the LM result is adopted as the initial guess of the LM method in the subsequent localization process. In 20 groups of 500 localizations, the average localization success rates of the particle swarm optimization-LM algorithm, whale optimization-LM algorithm, and the proposed IMWO-LM algorithm were 85.1%, 83.82%, and 98.28%, respectively. In the experiment of locating three magnetic targets simultaneously, the average position error and the average orientation error were 3.46 mm and 6.77°, respectively. Results show that this method can significantly improve the localization success rate while maintaining high localization accuracy.

15 May 2019 in IEEE Access
Verified
Journal Article
Open access
BLBowen Lv
Bowen Lv
YCYuangui Chen
Yuangui Chen
HDHoude Dai
Houde Dai
SSShijian Su
Shijian Su
MLMingqiang Lin
Mingqiang Lin
The magnetic tracking system, which is based on a permanent magnet and a magnetometer array, has numerous potential applications in the biomedical and industrial area. However, its tracking accuracy drops off sharply with the increase of tracking distance because of both the interference of environmental magnetic field and sensor measurement noise. To extend the magnetic tracking range, two novel methods were proposed in this study. Firstly, state-of-the-art tri-axial tunnel magnetoresistance (TMR) sensors, which possess the most significant field sensitivity and signal-to-noise ratio (SNR) over other types of magnetoresistive sensors, were adopted to construct the sensor array. Secondly, a fusion approach was proposed for tracking range extending. The Particle Swarm Optimization -Levenberg Marquardt (PSO-LM) method based on the magnetic dipole model was applied in the near field (i.e., near-source zone), and the prior knowledge based back propagation neural network (PKBPNN) was adopted to the far field (i.e., far-source zone). In the transition zone, these two algorithms were fused by using an adaptive sigmoid function. The trained artificial neural network (ANN) model embodied the physical model errors, the sensor installation errors, and the inherent characteristics of adopted magnetometers. Therefore, it has greater tracking performance than singly using the PSO-LM in the far-source zone. Experimental results show that the tracking errors decrease from (18.2419.37mm, 12.4513.370) to (8.9511.74mm, 7.9712.080) in the tracking range between 216mm and 296mm. Besides, the tracking distance is extended to 396mm, with the position error of less than 25mm. It can be concluded that this approach has significantly extended the tracking range of the magnetic tracking system.

18 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YQYanding Qin
Yanding Qin
BLBowen Lv
Bowen Lv
HDHoude Dai
Houde Dai
JHJianda Han
Jianda Han
Magnet tracking is an emerging tracking method for medical instruments and biological tissues, such as endoscopes and catheters. Traditional magnet tracking technology typically uses an optimization algorithm or heuristic algorithm to estimate the pose of a permanent magnet according to the measured magnetic induction intensity. However, this technology is limited by the high delay and the poor quality of the initial solution. This article proposes a new magnetic localization method, i.e., a hybrid feedforward neural network and Levenberg–Marquardt (hFFNN-LM) algorithm. FFNN provides an adjusted initial solution to the LM algorithm for solving the nonlinear inverse magnetic problem. The hFFNN-LM algorithm is promising for real-time magnetic tracking as it provides satisfactory tolerance for initially estimated parameters and fast search speed. The average single localization time is 1.07 ms. The experimental results show that the proposed method has a very low tracking delay compared to some other popular LM-based methods. The proposed hFFNN-LM algorithm achieves superior localization performances, i.e., the mean position and orientation errors are tested to be 0.70 mm and 0.90°, respectively.

4 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SSShijian Su
Shijian Su
HDHoude Dai
Houde Dai
SCShuying Cheng
Shuying Cheng
PLPeijie Lin
Peijie Lin
CHChao Hu
Chao Hu
BLBowen Lv
Bowen Lv
Magnetic tracking approach (MTA) is mainly based on the observation of the magnetic field produced by a magnetic tracking target. A permanent magnet is usually employed as the tracking target, and magnetic dipole model is used to estimate the magnetic field. In this study, we introduce an intuitive method to solve the magnetic tracking problem based on graph optimization. A graph is constructed to formulate the tracking problem, whose nodes correspond to the poses of the permanent magnet at different time and whose edges represent constraints derived by sensor measurements. The accuracy and robustness of MTA play a vital role in biomedical and industrial applications. However, a potential abnormal edge will appear in the graph when a magnetic sensor is disturbed by an interference source like a small magnet, which will deteriorate the localization accuracy of MTA. To improve its robustness, Huber cost function is used to reduce the weight of the abnormal edge. Finally, experiments were carried out to verify the performance of the proposed approach with and without magnetic field interference. Comparing the localization errors with the MTA based on the standard Levenberg-Marquardt algorithm, the results illustrate that the proposed approach could achieve superior localization accuracy and anti-interference ability.

1 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HDHoude Dai
Houde Dai
LDLifei Dong
Lifei Dong
BLBowen Lv
Bowen Lv
YCYuangui Chen
Yuangui Chen
SSShuang Song
Shuang Song
SSShijian Su
Shijian Su
During lung cancer radiotherapy, tumor motion caused by respiration and heartbeat significantly affects radiotherapy efficacy. The real-time and high-precision tracking of the lung tumor during the radiotherapy process remains a big challenge, as the traditional tracking methods have disadvantages such as slow tracking speed, radiation issue, or tracking and radiotherapy cannot be carried out at the same time. In this study, a magnetic tracking technique based on three permanent magnets was employed to localize the tumor in real-time. Thus the precise lung cancer radiotherapy is achieved by adjusting the acceleration position through the magnetic tracking results. Technical verification shows that the tracked centroid accuracies of the simulated tumor based on both 1- and 3-dipole models were 1.38 ± 0.83 mm, where the tracked tumor diameter accuracy based on the 3-dipole model was 1.51 ± 1.30 mm. The phantom experiment indicates the centroid tracking accuracies of the simulated tumor based on both 1- and 3-dipole models were 0.36 ± 0.16 mm and 2.54 ± 1.02 mm, respectively, where the tumor diameter accuracy based on the 3-dipole model was 2.15 ± 0.78 mm. Hence, this permanent magnet-based tumor tracking technique can effectively improve the performance of robotic radiotherapy. Besides, the radiotherapy object can be further expanded from lung cancer to other cancers such as prostate cancer.

26 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YQYanding Qin
Yanding Qin
PGPengxiu Geng
Pengxiu Geng
BLBowen Lv
Bowen Lv
YMYiyang Meng
Yiyang Meng
ZSZhichao Song
Zhichao Song
JHJianda Han
Jianda Han
A multi-robot collaboration system can complete more complex tasks than a single robot system. Ensuring the calibration accuracy between robots in the system is a prerequisite for the effective inter-robot cooperation. This paper presents a dual-robot system for orthopedic surgeries, where the relationships between hand-eye, flange-tool, and robot-robot need to be calibrated. This calibration problem can be summarized to the solution of the matrix equation of AXB=YCZ. A combined solution is proposed to solve the unknown parameters in the equation of AXB=YCZ, which consists of the dual quaternion closed-form method and the iterative method based on Levenberg–Marquardt (LM) algorithm. The closed-form method is used to quickly obtain the initial value for the iterative method so as to increase the convergence speed and calibration accuracy of the iterative method. Simulation and experimental analyses are carried out to verify the accuracy and effectiveness of the proposed method.