Shijian Su

Shijian Su

Auto-generated profile, based on publicly available information

Shijian Su

Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Open access
SSShijian Su
Shijian Su
SYSishen Yuan
Sishen Yuan
MXMengya Xu
Mengya Xu
HGHuxin Gao
Huxin Gao
XYXiaoxiao Yang
Xiaoxiao Yang
Hongliang RenHongliang Ren
Hongliang Ren
Traditional magnetic tracking approaches based on mathematical models and optimization algorithms are computationally intensive, depend on initial guesses, and do not guarantee convergence to a global optimum. Although fully-supervised data-driven deep learning can solve the above issues, the demand for a comprehensive dataset hampers its applicability in magnetic tracking. Thus, we propose an annular magnet pose estimation network (called AMagPoseNet) based on dual-domain few-shot learning from a prior mathematical model, which consists of two sub-networks: PoseNet and CaliNet. PoseNet learns to estimate the magnet pose from the prior mathematical model, and CaliNet is designed to narrow the gap between the mathematical model domain (MMD) and the real-world domain (RWD). Experimental results reveal that AMagPoseNet outperforms the optimization-based method regarding localization accuracy (1.87 $\pm$ 1.14 mm, 1.89 $\pm 0.81^{\circ }$ ), robustness (non-dependence on initial guesses), and computational latency (2.08 $\pm$ 0.02 ms). In addition, the six degrees of freedom (6-DoF) pose of the magnet could be estimated when discriminative magnetic field features are provided. With the assistance of the mathematical model, AMagPoseNet requires only a few real-world samples and has excellent performance, showing great potential for practical biomedical and industrial applications.

30 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BLBowen Lv
Bowen Lv
YQYanding Qin
Yanding Qin
HDHoude Dai
Houde Dai
SSShijian Su
Shijian Su
Magnetic localization technique has the advantages of millimeter-level localization accuracy, fast localization speed, and no limit-of-sight constraints. However, most studies are limited to the tracking of single or two magnets because of the low localization success rate for multiple magnets, thereby restricting its application scenarios. In this study, a novel multi-magnetic target localization method, named individual memory-based whale optimization and Levenberg-Marquardt (IMWO-LM) algorithm, is proposed to overcome the problem of low localization success rate. The IMWO algorithm adds the individual historical optimal location memory to each whale, which improves the global search ability of the population. This IMWO algorithm result is employed as the initial guess of the LM method. Afterward, the LM result is adopted as the initial guess of the LM method in the subsequent localization process. In 20 groups of 500 localizations, the average localization success rates of the particle swarm optimization-LM algorithm, whale optimization-LM algorithm, and the proposed IMWO-LM algorithm were 85.1%, 83.82%, and 98.28%, respectively. In the experiment of locating three magnetic targets simultaneously, the average position error and the average orientation error were 3.46 mm and 6.77°, respectively. Results show that this method can significantly improve the localization success rate while maintaining high localization accuracy.

1 November 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HDHoude Dai
Houde Dai
CHChao Hu
Chao Hu
SSShijian Su
Shijian Su
Mingqiang LinMingqiang Lin
Mingqiang Lin
SSShuang Song
Shuang Song
Based on a permanent magnet and a magnetometer array, magnetic tracking approach has some advantages such as wireless, real-time, and no line-of-sight problem. However, its tracking accuracy will be greatly deteriorated by the magnetometer array's rotating during the tracking process. The reason lies in the relative variation of triaxial geomagnetic components, which should be calibrated before the tracking process. In this paper, we proposed an inertial sensor-based geomagnetic compensation method to reduce the intervention of the triaxial geomagnetic components for the magnetic tracking performance. An inertial measurement unit, which is situated on the magnetometer array, can capture the triaxial rotation of the magnetometer array in real time. As the vector sum of the triaxial geomagnetic components is constant, the rotation vector of the magnetometer array can be converted to the variation of the triaxial geomagnetic components. Thus, the triaxial geomagnetic components, which are included in the magnetometer outputs, can be separated from the sensing signals of permanent magnet even if the magnetometer array is rotating. The experimental results indicate that the magnetic tracking accuracy has been significantly improved. This method extends the application scope of the magnetic tracking approach because it enables both the magnetometer array and magnet to rotate during the tracking process.

3 July 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Open access
JLJiewen Lai
Jiewen Lai
TRTian-Ao Ren
Tian-Ao Ren
WYWenchao YUE
Wenchao YUE
SSShijian Su
Shijian Su
Jason Y. K. ChanJason Y. K. Chan
Jason Y. K. Chan
Hongliang RenHongliang Ren
Hongliang Ren
To steer a soft robot precisely in an unconstructed environment with minimal collision remains an open challenge for soft robots. When the environments are unknown, prior motion planning for navigation may not always be available. This article presents a novel Sim-to-Real method to guide a cable-driven soft robot in a static environment under the Simulation Open Framework Architecture (SOFA). The scenario aims to resemble one of the steps during a simplified transoral tracheal intubation process where a robotic endotracheal tube is guided to the upper trachea–larynx location by a flexible video-assisted endoscope/stylet. In SOFA, we employ the quadratic programming inverse solver to obtain collision-free motion strategies for the endoscope/stylet manipulation based on the robot model and encode the virtual eye-in-hand vision. Then, we associate the anatomical features recognized by the virtual vision and the joint space motion using a closed-loop nonlinear autoregressive exogenous model (NARX) network. Afterward, we transfer the learned knowledge to the robot prototype, expecting it to navigate to the desired spot in a new phantom environment automatically based on its eye-in-hand vision only. Experiment results indicate that our soft robot can efficaciously navigate through the unstructured phantom to the desired spot with minimal collision motion according to what it has learned from the virtual environment. The results show that the average R-squared coefficient between the closed-loop NARX-forecasted and SOFA-referenced robot's cable and prismatic joint space motion are 0.963 and 0.997, respectively. The eye-in-hand visions also demonstrate a good alignment between the robot tip and the glottis.

4 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SSShijian Su
Shijian Su
HDHoude Dai
Houde Dai
SCShuying Cheng
Shuying Cheng
PLPeijie Lin
Peijie Lin
CHChao Hu
Chao Hu
BLBowen Lv
Bowen Lv
Magnetic tracking approach (MTA) is mainly based on the observation of the magnetic field produced by a magnetic tracking target. A permanent magnet is usually employed as the tracking target, and magnetic dipole model is used to estimate the magnetic field. In this study, we introduce an intuitive method to solve the magnetic tracking problem based on graph optimization. A graph is constructed to formulate the tracking problem, whose nodes correspond to the poses of the permanent magnet at different time and whose edges represent constraints derived by sensor measurements. The accuracy and robustness of MTA play a vital role in biomedical and industrial applications. However, a potential abnormal edge will appear in the graph when a magnetic sensor is disturbed by an interference source like a small magnet, which will deteriorate the localization accuracy of MTA. To improve its robustness, Huber cost function is used to reduce the weight of the abnormal edge. Finally, experiments were carried out to verify the performance of the proposed approach with and without magnetic field interference. Comparing the localization errors with the MTA based on the standard Levenberg-Marquardt algorithm, the results illustrate that the proposed approach could achieve superior localization accuracy and anti-interference ability.

1 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HDHoude Dai
Houde Dai
LDLifei Dong
Lifei Dong
BLBowen Lv
Bowen Lv
YCYuangui Chen
Yuangui Chen
SSShuang Song
Shuang Song
SSShijian Su
Shijian Su
During lung cancer radiotherapy, tumor motion caused by respiration and heartbeat significantly affects radiotherapy efficacy. The real-time and high-precision tracking of the lung tumor during the radiotherapy process remains a big challenge, as the traditional tracking methods have disadvantages such as slow tracking speed, radiation issue, or tracking and radiotherapy cannot be carried out at the same time. In this study, a magnetic tracking technique based on three permanent magnets was employed to localize the tumor in real-time. Thus the precise lung cancer radiotherapy is achieved by adjusting the acceleration position through the magnetic tracking results. Technical verification shows that the tracked centroid accuracies of the simulated tumor based on both 1- and 3-dipole models were 1.38 ± 0.83 mm, where the tracked tumor diameter accuracy based on the 3-dipole model was 1.51 ± 1.30 mm. The phantom experiment indicates the centroid tracking accuracies of the simulated tumor based on both 1- and 3-dipole models were 0.36 ± 0.16 mm and 2.54 ± 1.02 mm, respectively, where the tumor diameter accuracy based on the 3-dipole model was 2.15 ± 0.78 mm. Hence, this permanent magnet-based tumor tracking technique can effectively improve the performance of robotic radiotherapy. Besides, the radiotherapy object can be further expanded from lung cancer to other cancers such as prostate cancer.