24 August 2012 in IEEE Transactions on Power Electronics
DC microgrids are gaining popularity due to high efficiency, high reliability, and easy interconnection of renewable sources as compared to the ac system. Control objectives of dc microgrid are: 1) to ensure equal load sharing (in per unit) among sources; and 2) to maintain low-voltage regulation of the system. Conventional droop controllers are not effective in achieving both the aforementioned objectives simultaneously. Reasons for this are identified to be the error in nominal voltages and load distribution. Though centralized controller achieves these objectives, it requires high-speed communication and offers less reliability due to single point of failure. To address these limitations, this paper proposes a new decentralized controller for dc microgrid. Key advantages are high reliability, low-voltage regulation, and equal load sharing, utilizing low-bandwidth communication. To evaluate the dynamic performance, mathematical model of the scheme is derived. Stability of the system is evaluated by eigenvalue analysis. The effectiveness of the scheme is verified through a detailed simulation study. To confirm the viability of the scheme, experimental studies are carried out on a laboratory prototype developed for this purpose. Controller area network protocol is utilized to achieve communication between the sources.
16 November 2012 in IEEE Transactions on Industrial Electronics
Depleting fossil fuels, increasing energy demand, and need for high-reliability power supply motivate the use of dc microgrids. This paper analyzes the stability of low-voltage dc microgrid systems. Sources are controlled using a droop-based decentralized controller. Various components of the system have been modeled. A linearized system model is derived using small-signal approximation. The stability of the system is analyzed by identifying the eigenvalues of the system matrix. The sufficiency condition for stable operation of the system is derived. It provides upper bound on droop constants and is useful during planning and designing of dc microgrids. Furthermore, the sensitivity of system poles to variation in cable resistance and inductance is identified. It is proved that the poles move further inside the negative real plane with a decrease in inductance or an increase in resistance. The method proposed in this paper is applicable to any interconnecting structure of sources and loads. The results obtained by analysis are verified by detailed simulation study. Root locus plots are included to confirm the movement of system poles. The viability of the model is confirmed by experimental results from a scaled-down laboratory prototype of a dc microgrid developed for the purpose.
26 October 2016 in IEEE Transactions on Power Electronics
A novel scheme is proposed for online condition monitoring of bond wires present in insulated gate bipolar transistor (IGBT) package. The proposed method detects bond wire degradation using on-state collector emitter voltage at the inflection point. Previously reported condition monitoring methods based on on-state collector-emitter voltage as a precursor of aging require an accurate knowledge of junction temperature which is difficult to measure online during an inverter operation. The key advantage of the proposed scheme is that it monitors the bond wire degradation irrespective of the junction temperature. Therefore, this technique is not affected by increase in junction temperature due to die attach degradation or change in ambient temperature. The proposed scheme is verified experimentally under realistic operating conditions.
28 April 2020 in IEEE Transactions on Sustainable Energy
Accommodating increased penetration of renewable energy resources like solar Photo-Voltaics (PV) imposes severe challenges on the voltage regulation of the traditionally designed distribution system. Battery Energy Storage Systems (BESS) can mitigate voltage regulation issues, as they can act quickly in response to the uncertainties introduced due to solar PV. However, if there is no coordination between existing devices such as On Load Tap Changing Transformers (OLTC) and BESS, then BESS takes all the burden and is generally over-utilized. The uncoordinated control schematic shall also lead to underutilization of OLTC. Hence, in this paper, a coordinated control strategy to control BESS along with OLTC is proposed to warrant acceptable voltage magnitudes across the distribution feeder. The formulated optimization problem aims to mitigate the voltage deviation from its required values while reducing the number of changes in tap positions and also enhancing the battery life. The improvement in voltage regulation and optimal utilization of resources by using the proposed coordinated scheme over the traditional uncoordinated scheme is demonstrated for the IEEE 13 bus and 33 bus distribution systems in MATLAB/ Simulink.
14 January 2014 in IEEE Transactions on Industrial Electronics
SGSaikrishna Kashyap Gundlapalli
Saikrishna Kashyap Gundlapalli
High efficiency and operating life of grid feeding solar photovoltaic (PV) inverters are demanded. Due to reduced dc-link capacitor requirement, current source inverter (CSI) offers higher reliability than the voltage source based solar inverter. However, conventional three-phase pulse width modulated (PWM) current source based solar inverter injects high earth leakage current into the grid. In order to suppress this current, an isolation transformer can be used. Use of this transformer increases the cost and size, and decreases overall efficiency. In order to address the aforementioned limitations, a modified CSI is proposed in this paper. The proposed inverter suppresses the earth leakage current without using an isolation transformer, thereby increasing the efficiency and reducing cost as compared to conventional current source based solar inverters. A mathematical model of the system is derived based on which controller for the operation of the inverter is designed. The effectiveness of the scheme is verified through detailed simulation study. To confirm the viability of the scheme, experimental studies are carried out on a scaled-down laboratory prototype.