1 January 2014 in Industrial Health
We evaluated total body burden of N,N-dimethylformamide (DMF) taken through the lung and skin by personal exposure of workers to DMF and urinalysis of N-methylformamide (NMF) and N-acetyl-S(N-methylcarbamoyl)-cysteine (AMCC). A total of 270 workers were engaged in four different jobs in a workplace distant from main production lines emanating high levels of DMF. They were not required to wear any personal protective equipment including respirators or gloves. We found that log-transformed urinary levels of NMF and AMCC increased with an increase in log-transformed concentrations of exposure to DMF. Urinary levels of NMF and AMCC were significantly higher in the summer than the winter, although there was no significant seasonal difference in the concentrations of exposure to DMF. Our findings suggested that the increased urinary levels of NMF and AMCC in the summer resulted in increased skin absorption of DMF due to an increased amount of DMF absorbed by the moisturized skin under humid and hot conditions. Seasonal changes in the relative internal exposure index confirmed the present finding of enhanced summertime skin absorption of DMF. AMCC is thought to be a useful biomarker for assessments of cumulative exposure to DMF over a workweek and for evaluations of workers' health effects.
1 January 2005 in Journal of Structural and Construction Engineering (Transactions of AIJ)
1 January 2021 in Environmental and Occupational Health Practice
Objectives: We investigated the protection performance of whole gloves by developing a straightforward permeability resistance method and evaluating the permeation over 480 min. Methods: The permeation time for toluene was obtained for seven glove types according to the Japanese Industrial Standards. In addition, the permeability resistance of whole gloves was evaluated from the ratio of collected amount of toluene in the passive layered sampler attached to the inside and outside of the glove. Results: The permeation times of the two types of polyurethane gloves evaluated were less than 1 min each. However, the percentages of toluene that permeated through the whole gloves determined by the developed method were 32.5% and 6.8% for the thin and thick gloves, respectively, at 480 min and 71.8% and 24.1% for the thin and thick gloves, respectively, at 1,440 min. Permeation times for all three types of layered films were more than 1,440 min, but the whole glove tests showed differences of 1.7%, 3.1%, and less than 0.1% at 1,440 min. The causes of these differences were assumed to be related to variations in thickness, type of material, and differences in deposition state of the various gloves. Conclusions: It became possible to grasp the permeation performance throughout whole chemical resistant gloves, which could not be known only with material testing, using a straightforward permeability test method.
1 January 2003 in Journal of Structural and Construction Engineering (Transactions of AIJ)
Permeability of placing joint of cement mortar during casting was measured for the specimens placed at various interval times at the combined environmental conditions of temperature and relative humidity. Temperature directly affects the permeability of them, and the rise of it increases permeability. However, a slight influence observed for humidity. Pore structure of placing joint zone was furthermore investigated by the Ga intrusion technique recently developed. The pore structure becomes coarse and finally a clear porous line appeared along placing joint, according to particularly rise of temperature as well as delay of the jointing time. Finally, the relation between permeability and proctor penetration resistance was discussed.
1 January 2004 in Journal of Structural and Construction Engineering (Transactions of AIJ)