Takamasa Aoki

Takamasa Aoki

Auto-generated profile, based on publicly available information

Takamasa Aoki

Management Headquarters, Kyushu Institute of Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Environmental and Occupational Health Practice
Verified
Journal Article
Open access
PDF file
TATakamasa Aoki
Takamasa Aoki
SISatoko Iwasawa
Satoko Iwasawa
SYShinobu Yamamoto
Shinobu Yamamoto
ATAkito Takeuchi
Akito Takeuchi
STShigeru Tanaka
Shigeru Tanaka
HMHiroyuki Miyauchi
Hiroyuki Miyauchi
Objectives: We investigated the protection performance of whole gloves by developing a straightforward permeability resistance method and evaluating the permeation over 480 min. Methods: The permeation time for toluene was obtained for seven glove types according to the Japanese Industrial Standards. In addition, the permeability resistance of whole gloves was evaluated from the ratio of collected amount of toluene in the passive layered sampler attached to the inside and outside of the glove. Results: The permeation times of the two types of polyurethane gloves evaluated were less than 1 min each. However, the percentages of toluene that permeated through the whole gloves determined by the developed method were 32.5% and 6.8% for the thin and thick gloves, respectively, at 480 min and 71.8% and 24.1% for the thin and thick gloves, respectively, at 1,440 min. Permeation times for all three types of layered films were more than 1,440 min, but the whole glove tests showed differences of 1.7%, 3.1%, and less than 0.1% at 1,440 min. The causes of these differences were assumed to be related to variations in thickness, type of material, and differences in deposition state of the various gloves. Conclusions: It became possible to grasp the permeation performance throughout whole chemical resistant gloves, which could not be known only with material testing, using a straightforward permeability test method.

1 January 2025 in Environmental and Occupational Health Practice
Verified
Journal Article
Open access
PDF file
SISatoko Iwasawa
Satoko Iwasawa
TATakamasa Aoki
Takamasa Aoki
MFMorinao Fukuoka
Morinao Fukuoka
MMMasahiro Miyata
Masahiro Miyata
KSKunio Shibata
Kunio Shibata
HMHiroyuki Miyauchi
Hiroyuki Miyauchi
Objective: There is a demand for information on the proper selection, use, and maintenance of impermeable chemical protective gloves to prevent direct skin contact with hazardous substances. This review aims to summarize simplified testing methods for evaluating glove performance. Methods: The survey highlighted a lack of awareness regarding permeation resistance in glove selection. Various simplified testing methods were developed, such as real-time monitoring and gas chromatography, to evaluate the permeation resistance of chemical protective gloves, including the efficacy of multilayer films in reducing permeation. Results: The investigation revealed significant flaws in glove selection regarding permeation resistance to chemicals. Analysis showed that thin nitrile gloves offer inadequate protection against chloroform, while laminated film gloves demonstrated strong resistance to various chemicals. Real-time monitoring facilitated glove performance evaluation and confirmed that commonly used gloves may still allow harmful substances to permeate. Conclusion: The review underscores the urgent need for simplified permeation testing methods, enabling workers to make informed choices about glove materials based on their specific workplace hazards. Implementing these testing methodologies and adhering to updated safety regulations will better protect workers from chemical exposure, particularly in environments handling hazardous substances. Further research and development of glove materials with improved permeation resistance are recommended to enhance occupational safety.