Boiling water reactor (BWR) fuel at burnup of 41 to 45 GWd/tonne U was pulse irradiated in the Nuclear Safety Research Reactor (NSRR) to investigate fuel behavior under cold startup reactivity-initiated-accident conditions. Current Japanese BWR fuel, 8 × 8BJ type (Step I), from Fukushima-Daiichi Unit 3 was refabricated into short segments, and the test rods were promptly subjected to thermal energy from 293 to 607 J/g (70 to 145 cal/g) within ~20 ms. The fuel cladding was ductile enough to survive the prompt deformation due to pellet cladding mechanical interaction, while the plastic hoop strain reached 1.5% at the peak location. Transient fission gas release by the pulse irradiation varied from 3.1 to 8.2%, depending on the peak fuel enthalpy and the steady-state operation conditions.
13 May 2021 in Superconductor Science and Technology
We measured 1 H nuclear magnetic resonance (NMR) spectra from silicon rubber in a magnetic field trapped by a compact tubular MgB 2 superconductor bulk magnet (60 mm outer diameter, 40 mm inner diameter, and 60 mm height) which was magnetized by field-cooled magnetization from an applied field, , of 0.4778 T at 20 K. The sharpest 1 H NMR spectrum of the resonant frequency, , of 20.314 MHz, which corresponded to a field strength of 0.4771 T, was observed at 1 mm below the center of the bore of the MgB 2 tube. The homogeneity of the trapped field was within 100 ppm between z −2 and +2 mm along the central z -axis, which was evaluated by the position-dependent . No change in the trapped field was observed for about 25 d, which corresponded to a decay rate of less than 0.1 ppb h −1 . The obtained results suggest that the MgB 2 bulk magnet is a promising candidate for a magnetic pole in an NMR apparatus.
22 March 2022 in IEEE Transactions on Applied Superconductivity
We have succeeded in getting 1H NMR signals at 47.8 MHz (1.12 T) from a single-sided HTS bulk magnet activated by pulse-field magnetization. Diffusion NMR using an inhomogeneous outer field was also demonstrated on the surface. This kind of NMR relaxometry can not get the information of molecular structures, which conventional NMR using a homogeneous magnetic field can acquire. However, the relaxation of nuclear spin magnetization is still observable. A higher magnetic field gradient generated by the small HTS bulk magnet, 67 T/m at a 5 mm distance from the surface, can be effectively used to observe the self-diffusion coefficient of liquids in higher spatial resolution, 44 m. The easy accessibility to the strong field gradient is one of the unique properties of compact HTS bulk magnets. We believe that single-sided (unilateral) diffusion NMR will become the new application of HTS bulk magnets.
7 November 2005 in Superconductor Science and Technology
Solar panel failure is putatively caused by electrostatic charge and discharge. An investigation of its causes and efforts to determine measures for the future require both verification under as realistic a space environment as possible and enhanced ground tests. A plasma chamber was developed at the Tsukuba Space Center to carry out charge/discharge tests to verify low-Earth-orbit satellites solar panel durability against electrostatic discharge (ESD). This paper describes results of solar panel ESD tests at extremely low temperatures. The primary arc inception threshold voltages at 160 K and 230 K were similar at room temperature. In contrast, the rate of primary arc inception of 230 K was five times and the rate of primary arc inception of 160 K was ten times as much as that at 300 K at applied voltage 200 V. We also measured the capacitance C and dielectric constant epsivtau of the cover glass, which shows high resistivity and which is fairly constant over many frequencies. Apparently, the dielectric constant values have a slight influence on the rate of primary arc inception.