Takashi Nakamura

Takashi Nakamura

Auto-generated profile, based on publicly available information

Takashi Nakamura

RIKEN, Yokohama, Japan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
TNTakashi Nakamura
Takashi Nakamura
DTDaiki Tamada
Daiki Tamada
YYYousuke Yanagi
Yousuke Yanagi
YIYoshitaka Itoh
Yoshitaka Itoh
TNTakahiro Nemoto
Takahiro Nemoto
KKKatsumi Kose
Katsumi Kose

5 April 2007 in Concepts in Magnetic Resonance Part B
Verified
Journal Article
Closed access
PDF file
TNTakashi Nakamura
Takashi Nakamura
YIYoshitaka Itoh
Yoshitaka Itoh
MYMasaaki Yoshikawa
Masaaki Yoshikawa
TOTetsuo Oka
Tetsuo Oka
JUJun Uzawa
Jun Uzawa

6 June 2011 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
KOKyohei Ogawa
Kyohei Ogawa
TNTakashi Nakamura
Takashi Nakamura
YTYasuhiko Terada
Yasuhiko Terada
KKKatsumi Kose
Katsumi Kose
THTomoyuki Haishi
Tomoyuki Haishi
We have developed the first magnetic resonance (MR) microscope using a high critical-temperature superconducting bulk magnet. The bulk magnet comprises six annular bulk superconductors (60 mm outer diameter, 28 mm inner diameter, 20 mm high) made of c-axis oriented single-domain EuBa2Cu3Oy crystals. The magnet was energized using a superconducting NMR magnet operating at 4.7 T. The inhomogeneity of the trapped magnetic field measured with MR imaging was 3.1 ppm (rms) in the ϕ6.2 mm×9.1 mm cylindrical region. Three-dimensional MR images of a chemically fixed mouse embryo acquired with voxels of (50 μm)3 demonstrated the potential of our system.

30 December 2015 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
HMHidehiko Mochizuki
Hidehiko Mochizuki
HFHiroyuki Fujishiro
Hiroyuki Fujishiro
TNTomoyuki Naito
Tomoyuki Naito
YIYoshitaka Itoh
Yoshitaka Itoh
YYYousuke Yanagi
Yousuke Yanagi
TNTakashi Nakamura
Takashi Nakamura
We have performed pulsed field magnetization (PFM) for the GdBaCuO ring bulk (60 mm in outer diameter, 36 mm in inner diameter, and 17 mm in thickness) with an aluminum alloy bandage at 65 K. When a magnetic pulsed field over 3 T was applied, a fracture was confirmed in the bulk by the trapped field profile. Using a numerical simulation by a finite-element method, the trapped field and the hoop (σ θ ) and radial (σ r ) stresses were analyzed. A huge compressive stress concentrated at the inner peripheral edge of the ring bulk mainly by the thermal contraction. The additional compressive stress was applied by the flux-pinning-induced magnetostriction around the maximum field during PFM. The mechanical reinforcement in the inner periphery part of the ring bulk must be considered during PFM using a cylinder.

9 October 2013 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
TOTetsuo Oka
Tetsuo Oka
EHEri Hirayama
Eri Hirayama
TKTomoaki Kanai
Tomoaki Kanai
JOJun Ogawa
Jun Ogawa
SFSatoshi Fukui
Satoshi Fukui
TNTakashi Nakamura
Takashi Nakamura
The magnetic field distributions of an HTS bulk magnet system were precisely measured between the face-to-face 3.4-T magnetic poles. After the activation by 5-T field cooling magnetization, the magnetic flux density has reached the value of 2.26 T at the center of the 34-mm gap. The sum of the local magnetic fields generated from each magnetic pole coincides with the local field strength in the gap. We estimated the homogeneity of the magnetic flux densities of Bz and By, which were measured at various positions along z and y-axes in the center portion of the 60-mm gap. Since the magnetic flux density becomes smooth with increasing distance, we obtained the smallest distribution range of 123 ppm of Bz = 1.62 T at the center of the gap as for Bz. On the other, as for By, the smallest distribution range of 1125 ppm of Bz = 1.20 T was obtained at z = 1.7 mm distant from the center point. Since there must exist a certain plane which has no vector components along the radius direction at the center of the gap, the closer the z-positions come to the null point, the more homogeneous the field distribution becomes.

13 May 2021 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
YTYuhei Takahashi
Yuhei Takahashi
TNTomoyuki Naito
Tomoyuki Naito
TNTakashi Nakamura
Takashi Nakamura
MTMasato Takahashi
Masato Takahashi
We measured 1 H nuclear magnetic resonance (NMR) spectra from silicon rubber in a magnetic field trapped by a compact tubular MgB 2 superconductor bulk magnet (60 mm outer diameter, 40 mm inner diameter, and 60 mm height) which was magnetized by field-cooled magnetization from an applied field, B a p p , of 0.4778 T at 20 K. The sharpest 1 H NMR spectrum of the resonant frequency, f R , of 20.314 MHz, which corresponded to a field strength of 0.4771 T, was observed at 1 mm below the center of the bore of the MgB 2 tube. The homogeneity of the trapped field was within 100 ppm between z = −2 and +2 mm along the central z -axis, which was evaluated by the position-dependent f R . No change in the trapped field was observed for about 25 d, which corresponded to a decay rate of less than 0.1 ppb h −1 . The obtained results suggest that the MgB 2 bulk magnet is a promising candidate for a magnetic pole in an NMR apparatus.