Augusto Lio da Mota Goncalves Filho

Augusto Lio da Mota Goncalves Filho

Auto-generated profile, based on publicly available information

Augusto Lio da Mota Goncalves Filho

From the Department of Radiology, Radiation Oncology, and Medical Physics, Ottawa Hospital, University of Ottawa, 501 Smyth Rd, Box 232, General Campus Rm 1466e, Ottawa, ON, Canada K1H 8L6 (A.G.F.); Department of Radiology and Imaging Sciences, Emory University, Atlanta, Ga (C.G.); Department of Radiology, Mercy Catholic Medical Center, Darby, Pa (V.G.); and Department of Radiology, Urology and Nephrology Center, Mansoura University, Mansoura, Egypt (T.E.D., H.S.).

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in RadioGraphics
Verified
Journal Article
Closed access
DFDiego Cardoso Fragoso
Diego Cardoso Fragoso
AFAugusto Lio da Mota Gonçalves Filho
Augusto Lio da Mota Gonçalves Filho
FPFelipe Torres Pacheco
Felipe Torres Pacheco
BBBernardo Rodi Barros
Bernardo Rodi Barros
ILIngrid Aguiar Littig
Ingrid Aguiar Littig
ARAntônio Jose da Rocha
Antônio Jose da Rocha
The article provides an update on Creutzfeldt-Jakob disease (CJD), reviewing prion biology, subtypes of sporadic CJD, and the clinical aspects and molecular basis of this entity, with a comprehensive pictorial review of neuroimaging findings and differential diagnoses, enabling radiologists to confidently recognize this rare but invariably lethal disease. Diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD) remains a challenge because of the large variability of the clinical scenario, especially in its early stages, which may mimic several reversible or treatable disorders. The molecular basis of prion disease, as well as its brain propagation and the pathogenesis of the illness, have become better understood in recent decades. Several reports have listed recognizable clinical features and paraclinical tests to supplement the replicable diagnostic criteria in vivo. Nevertheless, we lack specific data about the differential diagnosis of CJD at imaging, mainly regarding those disorders evolving with similar clinical features (mimicking disorders). This review provides an update on the neuroimaging patterns of sCJD, emphasizing the relevance of magnetic resonance (MR) imaging, summarizing the clinical scenario and molecular basis of the disease, and highlighting clinical, genetic, and imaging correlations in different subtypes of prion diseases. A long list...

31 December 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
BCBryan Clifford
Bryan Clifford
JCJohn Conklin
John Conklin
SHSusie Y. Huang
Susie Y. Huang
TFThorsten Feiweier
Thorsten Feiweier
ZHZahra Hosseini
Zahra Hosseini
SCStephen Cauley
Stephen Cauley

27 October 2020 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
AFAugusto Lio M. Goncalves Filho
Augusto Lio M. Goncalves Filho
JCJohn Conklin
John Conklin
MLMaria Gabriela F. Longo
Maria Gabriela F. Longo
SCStephen F. Cauley
Stephen F. Cauley
DPDaniel Polak
Daniel Polak
OROtto Rapalino
Otto Rapalino
Background and Purpose: Brain magnetic resonance imaging (MRI) examinations using high-resolution 3D post-contrast sequences offer increased sensitivity for the detection of metastases in the central nervous system but are usually long exams. We evaluated whether the diagnostic performance of a highly accelerated Wave-controlled aliasing in parallel imaging (Wave-CAIPI) post-contrast 3D T1 SPACE sequence was non-inferior to the standard high-resolution 3D T1 SPACE sequence for the evaluation of brain metastases. Materials and Methods: Thirty-three patients undergoing evaluation for brain metastases were prospectively evaluated with a standard post-contrast 3D T1 SPACE sequence and an optimized Wave-CAIPI 3D T1 SPACE sequence, which was three times faster than the standard sequence. Two blinded neuroradiologists performed a head-to-head comparison to evaluate the visualization of pathology, perception of artifacts, and the overall diagnostic quality. Wave–CAIPI post-contrast T1 SPACE was tested for non-inferiority relative to standard T1 SPACE using a 15% non-inferiority margin. Results: Wave–CAIPI post-contrast T1 SPACE was non-inferior to the standard T1 SPACE for visualization of enhancing lesions (P < 0.01) and offered equivalent diagnostic quality performance and only marginally higher background noise compared to the standard sequence. Conclusions: Our findings suggest that Wave-CAIPI post-contrast T1 SPACE provides equivalent visualization of pathology and overall diagnostic quality with three times reduced scan time compared to the standard 3D T1 SPACE.

8 July 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
CNChanon Ngamsombat
Chanon Ngamsombat
AFA.L.M. Gonçalves Filho
A.L.M. Gonçalves Filho
MLM.G.F. Longo
M.G.F. Longo
SCS.F. Cauley
S.F. Cauley
KSKawin Setsompop
Kawin Setsompop
SHS.Y. Huang
S.Y. Huang
BACKGROUND AND PURPOSE: Our aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave–controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting. MATERIALS AND METHODS: Forty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student t tests, intraclass correlation coefficients, relative lesion volume difference, and Dice similarity coefficients were used to compare volumetric measurements among sequences. Two blinded neuroradiologists evaluated the visualization of white matter lesions, artifacts, and overall diagnostic quality using a predefined 5-point scale. RESULTS: Standard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84–0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (P < .001), and there were fewer pulsation artifacts on Wave-FLAIR compared with standard FLAIR (P < .001). CONCLUSIONS: Ultrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.

3 June 2021 in Journal of Neuroimaging
Verified
Journal Article
Closed access
PDF file
AFAugusto Lio M. Goncalves Filho
Augusto Lio M. Goncalves Filho
MLM. Gabriela Figueiro Longo
M. Gabriela Figueiro Longo
JCJohn Conklin
John Conklin
SCStephen F. Cauley
Stephen F. Cauley
DPDaniel Polak
Daniel Polak
OROtto Rapalino
Otto Rapalino

9 January 2024 in The Neuroradiology Journal
Verified
Journal Article
Closed access
KAKomal M Awan
Komal M Awan
AFAugusto Lio M Goncalves Filho
Augusto Lio M Goncalves Filho
ATAzadeh Tabari
Azadeh Tabari
BABrooks P Applewhite
Brooks P Applewhite
MLMin Lang
Min Lang
JCJohn Conklin
John Conklin
Background and Purpose: Deep learning (DL) accelerated MR techniques have emerged as a promising approach to accelerate routine MR exams. While prior studies explored DL acceleration for specific lumbar MRI sequences, a gap remains in comprehending the impact of a fully DL-based MRI protocol on scan time and diagnostic quality for routine lumbar spine MRI. To address this, we assessed the image quality and diagnostic performance of a DL-accelerated lumbar spine MRI protocol in comparison to a conventional protocol. Methods: We prospectively evaluated 36 consecutive outpatients undergoing non-contrast enhanced lumbar spine MRIs. Both protocols included sagittal T1, T2, STIR, and axial T2-weighted images. Two blinded neuroradiologists independently reviewed images for foraminal stenosis, spinal canal stenosis, nerve root compression, and facet arthropathy. Grading comparison employed the Wilcoxon signed rank test. For the head-to-head comparison, a 5-point Likert scale to assess image quality, considering artifacts, signal-to-noise ratio (SNR), anatomical structure visualization, and overall diagnostic quality. We applied a 15% noninferiority margin to determine whether the DL-accelerated protocol was noninferior. Results: No significant differences existed between protocols when evaluating foraminal and spinal canal stenosis, nerve compression, or facet arthropathy (all p > .05). The DL-spine protocol was noninferior for overall diagnostic quality and visualization of the cord, CSF, intervertebral disc, and nerve roots. However, it exhibited reduced SNR and increased artifact perception. Interobserver reproducibility ranged from moderate to substantial (κ = 0.50–0.76). Conclusion: Our study indicates that DL reconstruction in spine imaging effectively reduces acquisition times while maintaining comparable diagnostic quality to conventional MRI.