Malia McAvoy

Malia McAvoy

Auto-generated profile, based on publicly available information

Malia McAvoy

Department of Neurological Surgery, University of Washington, Seattle, Washington, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MMMalia McAvoy
Malia McAvoy
PPPaola Calvachi Prieto
Paola Calvachi Prieto
JKJakub R. Kaczmarzyk
Jakub R. Kaczmarzyk
IFIván Sánchez Fernández
Iván Sánchez Fernández
JMJack McNulty
Jack McNulty
OAOmar Arnaout
Omar Arnaout
A subset of primary central nervous system lymphomas (PCNSL) are difficult to distinguish from glioblastoma multiforme (GBM) on magnetic resonance imaging (MRI). We developed a convolutional neural network (CNN) to distinguish these tumors on contrast-enhanced T1-weighted images. Preoperative brain tumor MRIs were retrospectively collected among 320 patients with either GBM (n = 160) and PCNSL (n = 160) from two academic institutions. The individual images from these MRIs consisted of a training set (n = 1894 GBM and 1245 PCNSL), a validation set (n = 339 GBM; 202 PCNSL), and a testing set (99 GBM and 108 PCNSL). Three CNNs using the EfficientNetB4 architecture were evaluated. To increase the size of the training set and minimize overfitting, random flips and changes to color were performed on the training set. Our transfer learning approach (with image augmentation and 292 epochs) yielded an AUC of 0.94 (95% CI: 0.91–0.97) for GBM and an AUC of 0.95 (95% CI: 0.92–0.98) for PCNL. In the second case (not augmented and 137 epochs), the images were augmented prior to training. The area under the curve for GBM was 0.92 (95% CI: 0.88–0.96) for GBM and an AUC of 0.94 (95% CI: 0.91–0.97) for PCNSL. For the last case (augmented, Gaussian noise and 238 epochs) the AUC for GBM was 0.93 (95% CI: 0.89–0.96) and an AUC 0.93 (95% CI = 0.89–0.96) for PCNSL. Even with a relatively small dataset, our transfer learning approach demonstrated CNNs may provide accurate diagnostic information to assist radiologists in distinguishing PCNSL and GBM.

1 July 2021 in World Neurosurgery
Verified
Journal Article
Closed access
PCPaola Calvachi-Prieto
Paola Calvachi-Prieto
MMMalia B. McAvoy
Malia B. McAvoy
CCChristian D. Cerecedo-Lopez
Christian D. Cerecedo-Lopez
Yi LuYi Lu
Yi Lu
JCJohn H. Chi
John H. Chi
HZHasan A. Zaidi
Hasan A. Zaidi

7 June 2021 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MMMalia McAvoy
Malia McAvoy
ABAi-Tram N. Bui
Ai-Tram N. Bui
CHChristopher Hansen
Christopher Hansen
DPDeborah Plana
Deborah Plana
JSJordan T. Said
Jordan T. Said
NLNicole R. LeBoeuf
Nicole R. LeBoeuf
Background: In response to supply shortages caused by the COVID-19 pandemic, N95 filtering facepiece respirators (FFRs or “masks”), which are typically single-use devices in healthcare settings, are routinely being used for prolonged periods and in some cases decontaminated under “reuse” and “extended use” policies. However, the reusability of N95 masks is limited by degradation of fit. Possible substitutes, such as KN95 masks meeting Chinese standards, frequently fail fit testing even when new. The purpose of this study was to develop an inexpensive frame for damaged and poorly fitting masks using readily available materials and 3D printing. Results: An iterative design process yielded a mask frame consisting of two 3D printed side pieces, malleable wire links that users press against their face, and cut lengths of elastic material that go around the head to hold the frame and mask in place. Volunteers (n = 45; average BMI = 25.4), underwent qualitative fit testing with and without mask frames wearing one or more of four different brands of FFRs conforming to US N95 or Chinese KN95 standards. Masks passed qualitative fit testing in the absence of a frame at rates varying from 48 to 94 % (depending on mask model). For individuals who underwent testing using respirators with broken or defective straps, 80–100 % (average 85 %) passed fit testing with mask frames. Among individuals who failed fit testing with a KN95, ~ 50 % passed testing by using a frame. Conclusions: Our study suggests that mask frames can prolong the lifespan of N95 and KN95 masks by serving as a substitute for broken or defective bands without adversely affecting fit. Use of frames made it possible for ~ 73 % of the test population to achieve a good fit based on qualitative and quantitative testing criteria, approaching the 85–90 % success rate observed for intact N95 masks. Frames therefore represent a simple and inexpensive way of expanding access to PPE and extending their useful life. For clinicians and institutions interested in mask frames, designs and specifications are provided without restriction for use or modification. To ensure adequate performance in clinical settings, fit testing with user-specific masks and PanFab frames is required.

26 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
MMMalia McAvoy
Malia McAvoy
ABAi-Tram N. Bui
Ai-Tram N. Bui
CHChristopher Hansen
Christopher Hansen
DPDeborah Plana
Deborah Plana
JSJordan T. Said
Jordan T. Said
NLNicole R. LeBoeuf
Nicole R. LeBoeuf
Background: In response to supply shortages during the COVID-19 pandemic, N95 filtering facepiece respirators (FFRs or “masks”), which are typically single-use devices in healthcare settings, are routinely being used for prolonged periods and in some cases decontaminated under “reuse” and “extended use” policies. However, the reusability of N95 masks is often limited by degradation or breakage of elastic head bands and issues with mask fit after repeated use. The purpose of this study was to develop a frame for N95 masks, using readily available materials and 3D printing, which could replace defective or broken bands and improve fit. Results: An iterative design process yielded a mask frame consisting of two 3D-printed side pieces, malleable wire links that users press against their face, and cut lengths of elastic material that go around the head to hold the frame and mask in place. Volunteers (n= 41; average BMI= 25.5), of whom 31 were women, underwent qualitative fit with and without mask frames and one or more of four different brands of FFRs conforming to US N95 or Chinese KN95 standards. Masks passed qualitative fit testing in the absence of a frame at rates varying from 48 – 92% (depending on mask model and tester). For individuals for whom a mask passed testing, 75-100% (average = 86%) also passed testing with a frame holding the mask in place. Among users for whom a mask failed in initial fit testing, 41% passed using a frame. Success varied with mask model and across individuals. Conclusions: The use of mask frames can prolong the lifespan of N95 and KN95 masks by serving as a substitute for broken or defective bands without adversely affecting fit. Frames also have the potential to improve fit for some individuals who cannot fit existing masks. Frames therefore represent a simple and inexpensive way of extending the life and utility of PPE in short supply. For clinicians and institutions interested in mask frames, designs and specifications are provided without restriction for use or modification. To ensure adequate performance in clinical settings, qualitative fit testing with user-specific masks and frames is required.

15 September 2020 in Interventional Neuroradiology
Verified
Journal Article
Closed access
PDF file
MMMalia B McAvoy
Malia B McAvoy
JCJustin M Cappuzzo
Justin M Cappuzzo
CSChristopher J Stapleton
Christopher J Stapleton
MKMatthew J Koch
Matthew J Koch
SRScott B Raymond
Scott B Raymond
APAman B Patel
Aman B Patel
Background: The Penumbra SMART coil is a novel device that becomes progressively softer from its distal to proximal end to maximize coil packing and prevent microcatheter prolapse or coil migration. Here, we report a large series of patients detailing the long-term experience of a single institution using the SMART coil among patients with intracranial aneurysms (IAs). Methods: Prospective data of 105 consecutive patients with 106 IAs treated using SMART coils was collected between March 2015 and July 2018. Clinical and angiographic data were analyzed. Results: Forty-nine patients (46.7%) presented with subarachnoid hemorrhage and 16 (14.2%) had recurrent aneurysms. Two patients had minor intraprocedural ruptures and remained neurologically stable. One patient had a thromboembolic complication with progressive neurologic decline. There was only one case microcatheter prolapse related to placement of a stent before coiling. An initial post-treatment modified Raymond-Roy Occlusion Classification (mRROC) I or II closure was achieved in 56 (52.8%) aneurysms. The average time to last follow-up was 8.4 months at which 70 (81.4%) aneurysms had mRROC I or II occlusion and a major recurrence was seen in 5 (5.8%) patients. Thirteen (12.3%) aneurysms required re-treatment of which one aneurysm was clipped. Conclusions: The Penumbra SMART coil is safe and effective for the endovascular treatment of appropriately selected IAs. Additional studies at multiple centers comparing safety and efficacy profile over long-term periods to other mainstream coils are necessary.

17 September 2022 in World Neurosurgery
Verified
Journal Article
Closed access
GBGuilherme Barros
Guilherme Barros
RMR. Michael Meyer
R. Michael Meyer
DBDavid I. Bass
David I. Bass
DNDominic Nistal
Dominic Nistal
MMMalia McAvoy
Malia McAvoy
MLMichael R Levitt
Michael R Levitt