Rasmus Reinhold Paulsen

Rasmus Reinhold Paulsen

Auto-generated profile, based on publicly available information

Rasmus Reinhold Paulsen

Technical University of Denmark

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
ASM ShihavuddinASM Shihavuddin
ASM Shihavuddin
XCXiao Chen
Xiao Chen
VFVladimir Fedorov
Vladimir Fedorov
ACAnders Nymark Christensen
Anders Nymark Christensen
NRNicolai Riis
Nicolai Riis
RPRasmus Reinhold Paulsen
Rasmus Reinhold Paulsen
Timely detection of surface damages on wind turbine blades is imperative for minimizing downtime and avoiding possible catastrophic structural failures. With recent advances in drone technology, a large number of high-resolution images of wind turbines are routinely acquired and subsequently analyzed by experts to identify imminent damages. Automated analysis of these inspection images with the help of machine learning algorithms can reduce the inspection cost. In this work, we develop a deep learning-based automated damage suggestion system for subsequent analysis of drone inspection images. Experimental results demonstrate that the proposed approach can achieve almost human-level precision in terms of suggested damage location and types on wind turbine blades. We further demonstrate that for relatively small training sets, advanced data augmentation during deep learning training can better generalize the trained model, providing a significant gain in precision.

18 August 2011 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
OOOline Vinter Olesen
Oline Vinter Olesen
RPRasmus R. Paulsen
Rasmus R. Paulsen
LHLiselotte Hojgaard
Liselotte Hojgaard
BRBjarne Roed
Bjarne Roed
RLRasmus Larsen
Rasmus Larsen
We present a system for head motion tracking in 3D brain imaging. The system is based on facial surface reconstruction and tracking using a structured light (SL) scanning principle. The system is designed to fit into narrow 3D medical scanner geometries limiting the field of view. It is tested in a clinical setting on the high resolution research tomograph (HRRT), Siemens PET scanner with a head phantom and volunteers. The SL system is compared to a commercial optical tracking system, the Polaris Vicra system, from NDI based on translatory and rotary ground truth motions of the head phantom. The accuracy of the systems was similar, with root mean square (rms) errors of 0.09° for ±20° axial rotations, and rms errors of 0.24 mm for ± 25 mm translations. Tests were made using 1) a light emitting diode (LED) based miniaturized video projector, the Pico projector from Texas Instruments, and 2) a customized version of this projector replacing a visible light LED with a 850 nm near infrared LED. The latter system does not provide additional discomfort by visible light projection into the patient's eyes. The main advantage over existing head motion tracking devices, including the Polaris Vicra system, is that it is not necessary to place markers on the patient. This provides a simpler workflow and eliminates uncertainties related to marker attachment and stability. We show proof of concept of a marker less tracking system especially designed for clinical use with promising results.

19 September 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
OOOline V. Olesen
Oline V. Olesen
JSJenna M. Sullivan
Jenna M. Sullivan
TMTim Mulnix
Tim Mulnix
RPRasmus R. Paulsen
Rasmus R. Paulsen
LHLiselotte Hojgaard
Liselotte Hojgaard
RLRasmus Larsen
Rasmus Larsen
A custom designed markerless tracking system was demonstrated to be applicable for positron emission tomography (PET) brain imaging. Precise head motion registration is crucial for accurate motion correction (MC) in PET imaging. State-of-the-art tracking systems applied with PET brain imaging rely on markers attached to the patient's head. The marker attachment is the main weakness of these systems. A healthy volunteer participating in a cigarette smoking study to image dopamine release was scanned twice for 2 h with 11C-racolopride on the high resolution research tomograph (HRRT) PET scanner. Head motion was independently measured, with a commercial marker-based device and the proposed vision-based system. A list-mode event-by-event reconstruction algorithm using the detected motion was applied. A phantom study with hand-controlled continuous random motion was obtained. Motion was time-varying with long drift motions of up to 18 mm and regular step-wise motion of 1-6 mm. The evaluated measures were significantly better for motion-corrected images compared to no MC. The demonstrated system agreed with a commercial integrated system. Motion-corrected images were improved in contrast recovery of small structures.

11 October 2014 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
JFJens Fagertun
Jens Fagertun
SHStine Harder
Stine Harder
ARAnders Rosengren
Anders Rosengren
CMChristian Moeller
Christian Moeller
TWThomas Werge
Thomas Werge
THThomas F Hansen
Thomas F Hansen
Manual annotation of landmarks is a known source of variance, which exist in all fields of medical imaging, influencing the accuracy and interpretation of the results. However, the variability of human facial landmarks is only sparsely addressed in the current literature as opposed to e.g. the research fields of orthodontics and cephalometrics. We present a full facial 3D annotation procedure and a sparse set of manually annotated landmarks, in effort to reduce operator time and minimize the variance.

13 November 2009 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
RPRasmus R. Paulsen
Rasmus R. Paulsen
ABAndreas Bærentzen
Andreas Bærentzen
RLRasmus Larsen
Rasmus Larsen
A method for implicit surface reconstruction is proposed. The novelty in this paper is the adaption of Markov Random Field regularization of a distance field. The Markov Random Field formulation allows us to integrate both knowledge about the type of surface we wish to reconstruct (the prior) and knowledge about data (the observation model) in an orthogonal fashion. Local models that account for both scene-specific knowledge and physical properties of the scanning device are described. Furthermore, how the optimal distance field can be computed is demonstrated using conjugate gradients, sparse Cholesky factorization, and a multiscale iterative optimization scheme. The method is demonstrated on a set of scanned human heads and, both in terms of accuracy and the ability to close holes, the proposed method is shown to have similar or superior performance when compared to current state-of-the-art algorithms.

19 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JSJakob M. Slipsager
Jakob M. Slipsager
AEAndreas H. Ellegaard
Andreas H. Ellegaard
SGStefan L. Glimberg
Stefan L. Glimberg
RPRasmus R. Paulsen
Rasmus R. Paulsen
MTM. Dylan Tisdall
M. Dylan Tisdall
OOOline V. Olesen
Oline V. Olesen
We demonstrate and evaluate the first markerless motion tracker compatible with PET, MRI, and simultaneous PET/MRI systems for motion correction (MC) of brain imaging. PET and MRI compatibility is achieved by careful positioning of in-bore vision extenders and by placing all electronic components out-of-bore. The motion tracker is demonstrated in a clinical setup during a pediatric PET/MRI study including 94 pediatric patient scans. PET MC is presented for two of these scans using a customized version of the Multiple Acquisition Frame method. Prospective MC of MRI acquisition of two healthy subjects is demonstrated using a motion-aware MRI sequence. Real-time motion estimates are accompanied with a tracking validity parameter to improve tracking reliability. For both modalities, MC shows that motion induced artifacts are noticeably reduced and that motion estimates are sufficiently accurate to capture motion ranging from small respiratory motion to large intentional motion. In the PET/MRI study, a time-activity curve analysis shows image improvements for a patient performing head movements corresponding to a tumor motion of ±5-10 mm with a 19% maximal difference in standardized uptake value before and after MC. The first markerless motion tracker is successfully demonstrated for prospective MC in MRI and MC in PET with good tracking validity. As simultaneous PET/MRI systems have become available for clinical use, an increasing demand for accurate motion tracking and MC in PET/MRI scans has emerged. The presented markerless motion tracker facilitate this demand.